Monessen Hearth EYF24, EYF18 Placement in a Fireplace with a Restrictive Barrier

Page 10

PLACEMENT IN A FIREPLACE WITH A RESTRICTIVE BARRIER

IMPORTANT INFORMATION FOR THE INSTALLATION OF THIS GAS LOG SET

The following are guidelines for placing a gas log set in a fireplace that has a restrictive barrier along the bottom front open- ing of the fireplace. Some examples of barriers are glass/screen door frames and sunken/recessed fireplaces.

Height of Restriction (X)

Minimum Depth of Fireplace/Firebox

No restriction

13"

0 to 1.5"

16"

Greater than 11/2" to 3"

16"

Greater than 3"

Any barrier greater than three inches (3") placed in front of the gas log set is not

 

recommended by the manufacturer.

Glass door frames with adjustable louvers should have the lovers fully open while the unit is in operation.

Height of restrictive barrier X caused by glass door frames, recessed fireplaces, etc. from

the base or bottom surface of the unit. (See Table).

LO

HI

The log set should be placed against or as near as possible to the rear wall of the fireplace/firebox.

ON

I

OFF G

N

Depth of fireplace/firebox.

(SeeTable).

Figure 3 - Reference Drawing of a Natural Flame Log Set in an Enclosure

WARNING

Barriers such as the bottom of a glass door frame placed in front of a gas log set can change the air flow characteristics of the fireplace which in turn can cause the unit to overheat and malfunction.

NOTE: Non combustible material such as refractory brick may be used to line the floor of the fireplace in order to raise the height of the gas log set in relation to a restrictive barrier. If the unit is raised, the minimum height dimension listed in the homeowner’s manual must not be exceeded.

NOTE: If the log set is equipped with a remote receiver, a restrictive barrier may reduce the battery life by increasing the ambient temperature inside the fireplace. Placement of the receiver outside of the fireplace will extend the battery life.

10

65D1009

Image 10
Contents Unvented GAS LOG Heater or Vented Decorative Appliance What to do if YOU Smell GASContents Installer Important Safety InformationOwner Never connect unit to private Getting Started What YOU will Need for InstallationMake Sure YOU have Received ALL Parts Natural GAS Product Features and SpecificationsPROPANE/LPG Codes General Installation InformationAdequate Combustion and Ventilation AIR Counter Fireplace L1 = 151/2 Ft., L2 = 12 Ft., W = 12 Ft., H = 8 FtFireplace and Hearth Dimensions Placement in a Fireplace with a Restrictive Barrier Depth of fireplace/fireboxClearances and Height Requirements Sidewall and Ceiling ClearancesClearances and Height Requirements Minimum Mantel Clearance With Hood Floor Clearance Minimum Clearance above Combustible FlooringBefore Installing the Appliance Installing Vented ApplicationsBefore Fully Installing the Unit Damper Stop InstallationPlacing and Securing Appliance Installing Vented ApplicationAssembly Procedure Horizontal Grate Bar Hooks for Screw Middle Hole for AnchorConnecting the GAS Flexible Tube Manual Shutoff Gas Supply Inlet ValveNPT Test Plug Checking GAS PressureTest Port OUT Connecting Optional Wall Switch or Thermostat Electrical Wiring MillivoltRequire 110 VAC to Operate Checking System Operation Connecting Optional Remote ReceiverFollow Instructions Supplied with the Remote Remote Receiver Velcro PadsPlacing the Decorative Rock LOG PlacementInstalling EYF24-F LOG Unit on Burner Top Left Log Front Log Top Right Log Main Log TabsRear Log Middle Log #2 Installing EYF18-R LOG SET on UnitTop Log #4 Front Log #3 Front Top Right Log #4 Log #3 Installing EYF24-R or EYF30-R LOG SET on UnitRear Log #1 Middle Log Top Left Log #5Millivolt Control Flame AppearanceChecking the Pilot Flame Manual ControlChecking the Burner Flame Operating InstructionsOperating Instructions For Your Safety Read Before LightingPiezo Ignitor Switch Control KnobsManual Control Lighting Instructions To Turn OFF HeaterOn/Off Switch Piezo Hi/Lo Control On/Off/Pilot Control Millivolt Control Lighting InstructionsCleaning and Servicing Operating Instructions and Cleaning and ServicingMatch Lighting Instructions Troubleshooting Observed Prob Possible Cause RemedyODS/pilot lights, but flame Illustrated Parts Breakdown Replacement Parts List Replacement Parts are Available Through Your RetailerEYF24-F EYF18-RCarbon Monoxide Detector Requirements Basic Warranty Lifetime WarrantyFive Year Warranty Mhsc
Related manuals
Manual 32 pages 30.22 Kb

EYF24, EYF18 specifications

The Monessen Hearth EYF24 and EYF18 represent a perfect blend of style, efficiency, and innovative technology in the world of vent-free gas fireplaces. Designed for homeowners who desire warmth and ambiance without the complexities of traditional fireplaces, these units stand out as reliable heating solutions.

The EYF24 and EYF18 are designed with a sleek and modern aesthetic, making them suitable for a variety of home decors. Their compact size allows for versatile installation options, making them ideal for both small spaces and larger living areas. With a focus on ease of use, both models come equipped with user-friendly controls, enabling homeowners to adjust the flame height and heat output effortlessly.

One of the standout features of these Monessen fireplaces is their vent-free technology. This allows the units to operate efficiently without the need for a chimney or flue, which means less installation cost and hassle. The design also facilitates greater flexibility in placement, as they can be installed in virtually any room. Whether you want to enhance a cozy den or add warmth to a larger gathering space, the EYF24 and EYF18 are adaptable to your needs.

Another notable characteristic is their high-efficiency rating. Both models utilize advanced burner technology that maximizes heat output while minimizing energy consumption. This capability not only ensures a comfortable indoor environment but also helps in reducing heating costs. The units are designed to generate realistic flames, creating an inviting ambiance that can be enjoyed year-round.

In terms of safety, Monessen has integrated several features into the EYF24 and EYF18. The oxygen depletion sensor (ODS) automatically shuts off the unit if oxygen levels fall below safe limits, providing peace of mind for homeowners. Additionally, the units are designed to operate quietly, allowing for an undisturbed living experience.

Customization options also abound with these models. Homeowners can select from a range of decorative media, including logs, stones, and glass, to personalize their fireplace's appearance. This flexibility ensures that each installation can be uniquely tailored to match individual tastes and home styles.

In conclusion, the Monessen Hearth EYF24 and EYF18 fireplaces are excellent choices for anyone seeking a stylish, efficient, and safe heating solution. With their modern design, vent-free technology, and user-friendly features, they offer an inviting and warm atmosphere that can enhance any home environment.