Monessen Hearth EYF24, EYF18 operating instructions Millivolt Control Lighting Instructions

Page 28

OPERATING INSTRUCTIONS

MILLIVOLT CONTROL LIGHTING INSTRUCTIONS

1.STOP! Read the safety information label.

2.Make sure the manual shutoff valve is fully open.

3.This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo ignitor does not light the pilot, see instructions for Match Lighting Instructions, page 29.

4.Turn gas control knob clockwise to the OFF position. Turn ON/OFF switch to OFF position.

5.Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information label. If you don't smell gas, go to next step.

6.From OFF position, turn the gas control knob counterclockwise to IGN position. Push in control knob for 5 seconds.

7.With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.

8.Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shutting off the gas while the probe is warming up. Release the control knob.

9.Turn gas control knob counterclockwise to the ON position.

10.After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to ON position.

11.If the gas logs will not operate, follow the instructions To Turn Off Gas To Appliance below and call your service technician or gas supplier.

On/Off Switch

Piezo

Hi/Lo Control

On/Off/Pilot Control

Figure 39 - Pilot

Figure 40 - Control Cover Plate for Millivolt

TO TURN OFF HEATER

1.Turn control knob clockwise to OFF position to completely shut off the heater.

2.If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.

3.If applicable: Turn off all electric power to the heater.

28

65D1009

Image 28
Contents Unvented GAS LOG Heater or Vented Decorative Appliance What to do if YOU Smell GASContents Installer Important Safety InformationOwner Never connect unit to private Getting Started What YOU will Need for InstallationMake Sure YOU have Received ALL Parts Natural GAS Product Features and SpecificationsPROPANE/LPG Codes General Installation InformationAdequate Combustion and Ventilation AIR Counter Fireplace L1 = 151/2 Ft., L2 = 12 Ft., W = 12 Ft., H = 8 FtFireplace and Hearth Dimensions Placement in a Fireplace with a Restrictive Barrier Depth of fireplace/fireboxClearances and Height Requirements Sidewall and Ceiling ClearancesClearances and Height Requirements Minimum Mantel Clearance With Hood Floor Clearance Minimum Clearance above Combustible FlooringInstalling Vented Applications Before Fully Installing the UnitBefore Installing the Appliance Damper Stop InstallationInstalling Vented Application Assembly ProcedurePlacing and Securing Appliance Horizontal Grate Bar Hooks for Screw Middle Hole for AnchorConnecting the GAS Flexible Tube Manual Shutoff Gas Supply Inlet ValveNPT Test Plug Checking GAS PressureTest Port OUT Connecting Optional Wall Switch or Thermostat Electrical Wiring MillivoltRequire 110 VAC to Operate Connecting Optional Remote Receiver Follow Instructions Supplied with the RemoteChecking System Operation Remote Receiver Velcro PadsLOG Placement Installing EYF24-F LOG Unit on BurnerPlacing the Decorative Rock Top Left Log Front Log Top Right Log Main Log TabsRear Log Middle Log #2 Installing EYF18-R LOG SET on UnitTop Log #4 Front Log #3 Installing EYF24-R or EYF30-R LOG SET on Unit Rear Log #1 Middle LogFront Top Right Log #4 Log #3 Top Left Log #5Flame Appearance Checking the Pilot FlameMillivolt Control Manual ControlChecking the Burner Flame Operating InstructionsFor Your Safety Read Before Lighting Piezo Ignitor SwitchOperating Instructions Control KnobsManual Control Lighting Instructions To Turn OFF HeaterOn/Off Switch Piezo Hi/Lo Control On/Off/Pilot Control Millivolt Control Lighting InstructionsCleaning and Servicing Operating Instructions and Cleaning and ServicingMatch Lighting Instructions Troubleshooting Observed Prob Possible Cause RemedyODS/pilot lights, but flame Illustrated Parts Breakdown Replacement Parts List Replacement Parts are Available Through Your RetailerEYF24-F EYF18-RCarbon Monoxide Detector Requirements Lifetime Warranty Five Year WarrantyBasic Warranty Mhsc
Related manuals
Manual 32 pages 30.22 Kb

EYF24, EYF18 specifications

The Monessen Hearth EYF24 and EYF18 represent a perfect blend of style, efficiency, and innovative technology in the world of vent-free gas fireplaces. Designed for homeowners who desire warmth and ambiance without the complexities of traditional fireplaces, these units stand out as reliable heating solutions.

The EYF24 and EYF18 are designed with a sleek and modern aesthetic, making them suitable for a variety of home decors. Their compact size allows for versatile installation options, making them ideal for both small spaces and larger living areas. With a focus on ease of use, both models come equipped with user-friendly controls, enabling homeowners to adjust the flame height and heat output effortlessly.

One of the standout features of these Monessen fireplaces is their vent-free technology. This allows the units to operate efficiently without the need for a chimney or flue, which means less installation cost and hassle. The design also facilitates greater flexibility in placement, as they can be installed in virtually any room. Whether you want to enhance a cozy den or add warmth to a larger gathering space, the EYF24 and EYF18 are adaptable to your needs.

Another notable characteristic is their high-efficiency rating. Both models utilize advanced burner technology that maximizes heat output while minimizing energy consumption. This capability not only ensures a comfortable indoor environment but also helps in reducing heating costs. The units are designed to generate realistic flames, creating an inviting ambiance that can be enjoyed year-round.

In terms of safety, Monessen has integrated several features into the EYF24 and EYF18. The oxygen depletion sensor (ODS) automatically shuts off the unit if oxygen levels fall below safe limits, providing peace of mind for homeowners. Additionally, the units are designed to operate quietly, allowing for an undisturbed living experience.

Customization options also abound with these models. Homeowners can select from a range of decorative media, including logs, stones, and glass, to personalize their fireplace's appearance. This flexibility ensures that each installation can be uniquely tailored to match individual tastes and home styles.

In conclusion, the Monessen Hearth EYF24 and EYF18 fireplaces are excellent choices for anyone seeking a stylish, efficient, and safe heating solution. With their modern design, vent-free technology, and user-friendly features, they offer an inviting and warm atmosphere that can enhance any home environment.