MATCH LIGHTING INSTRUCTIONS

1.Remove any items necessary for easy access to the pilot (for example: logs, screens, etc.).

2.Follow appropriate lighting instructions found previously. Instead of pushing and releasing the piezo button, light a match and hold the flame to the end of the pilot and ignite the pilot.

3.After control knob has been released and pilot stays lit, reinstall any items that were removed for pilot ac- cess.

4.Call a qualified service technician for repair or replacement of the piezo ignitor.

CLEANING AND SERVICING

Annual inspection and cleaning by your dealer or qualified service technician is recommended to prevent malfunction and/or sooting.

WARNING

TurnWARNING off heater and allow to cool before cleaning.

Disconnect electrical power (optional blower) before cleaning or servicing.

Remove logs, handling carefully by holding gently at each end. Gloves are recommended to prevent skin irritation from ceramic fibers. If skin becomes irritated, wash gently with soap and water. See Log Placement, pages 21-23for correct log placement.

PERIODIC CLEANING - See parts diagram for location of items discussed below.

Do not use cleaning fluid to clean logs or any part of heater.

Brush logs with soft bristle brush or vacuum with brush attachment.

Vacuum loose particles and dust from the front and rear burner, control and piezo covers and grate weldment.

Inspect and clean burner air intake holes. Remove lint or particles with vacuum, brush, or pipe cleaners. Failure to keep air intake holes clean will result in sooting and poor combustion.

External case should be dusted and wiped with a wet soapy cloth.

ANNUAL CLEANING/INSPECTION - See parts diagram for location of items discussed below.

Inspect and clean burner air intake holes. Remove lint or particles with vacuum, brush or pipe cleaners. Failure to keep air intake holes clean will result in sooting and poor combustion.

Inspect and clean all burner ports.

Inspect ODS pilot for operation and accumulation of lint at air intake holes.

Verify flame pattern and log placement for proper operation.

Verify smooth and responsive ignition of main burner and rear burner.

65D1009

29

Image 29
Contents What to do if YOU Smell GAS Unvented GAS LOG Heater or Vented Decorative ApplianceContents Owner Important Safety InformationInstaller Never connect unit to private Make Sure YOU have Received ALL Parts What YOU will Need for InstallationGetting Started PROPANE/LPG Product Features and SpecificationsNatural GAS Adequate Combustion and Ventilation AIR General Installation InformationCodes L1 = 151/2 Ft., L2 = 12 Ft., W = 12 Ft., H = 8 Ft Counter FireplaceFireplace and Hearth Dimensions Depth of fireplace/firebox Placement in a Fireplace with a Restrictive BarrierSidewall and Ceiling Clearances Clearances and Height RequirementsClearances and Height Requirements Minimum Mantel Clearance With Hood Minimum Clearance above Combustible Flooring Floor ClearanceBefore Fully Installing the Unit Installing Vented ApplicationsBefore Installing the Appliance Damper Stop InstallationAssembly Procedure Installing Vented ApplicationPlacing and Securing Appliance Horizontal Grate Bar Hooks for Screw Middle Hole for AnchorFlexible Tube Manual Shutoff Gas Supply Inlet Valve Connecting the GASTest Port OUT Checking GAS PressureNPT Test Plug Require 110 VAC to Operate Electrical Wiring MillivoltConnecting Optional Wall Switch or Thermostat Follow Instructions Supplied with the Remote Connecting Optional Remote ReceiverChecking System Operation Remote Receiver Velcro PadsInstalling EYF24-F LOG Unit on Burner LOG PlacementPlacing the Decorative Rock Top Left Log Front Log Top Right Log Main Log TabsTop Log #4 Front Log #3 Installing EYF18-R LOG SET on UnitRear Log Middle Log #2 Rear Log #1 Middle Log Installing EYF24-R or EYF30-R LOG SET on UnitFront Top Right Log #4 Log #3 Top Left Log #5Checking the Pilot Flame Flame AppearanceMillivolt Control Manual ControlOperating Instructions Checking the Burner FlamePiezo Ignitor Switch For Your Safety Read Before LightingOperating Instructions Control KnobsTo Turn OFF Heater Manual Control Lighting InstructionsMillivolt Control Lighting Instructions On/Off Switch Piezo Hi/Lo Control On/Off/Pilot ControlMatch Lighting Instructions Operating Instructions and Cleaning and ServicingCleaning and Servicing Observed Prob Possible Cause Remedy TroubleshootingODS/pilot lights, but flame Illustrated Parts Breakdown Replacement Parts are Available Through Your Retailer Replacement Parts ListEYF18-R EYF24-FCarbon Monoxide Detector Requirements Five Year Warranty Lifetime WarrantyBasic Warranty Mhsc
Related manuals
Manual 32 pages 30.22 Kb

EYF24, EYF18 specifications

The Monessen Hearth EYF24 and EYF18 represent a perfect blend of style, efficiency, and innovative technology in the world of vent-free gas fireplaces. Designed for homeowners who desire warmth and ambiance without the complexities of traditional fireplaces, these units stand out as reliable heating solutions.

The EYF24 and EYF18 are designed with a sleek and modern aesthetic, making them suitable for a variety of home decors. Their compact size allows for versatile installation options, making them ideal for both small spaces and larger living areas. With a focus on ease of use, both models come equipped with user-friendly controls, enabling homeowners to adjust the flame height and heat output effortlessly.

One of the standout features of these Monessen fireplaces is their vent-free technology. This allows the units to operate efficiently without the need for a chimney or flue, which means less installation cost and hassle. The design also facilitates greater flexibility in placement, as they can be installed in virtually any room. Whether you want to enhance a cozy den or add warmth to a larger gathering space, the EYF24 and EYF18 are adaptable to your needs.

Another notable characteristic is their high-efficiency rating. Both models utilize advanced burner technology that maximizes heat output while minimizing energy consumption. This capability not only ensures a comfortable indoor environment but also helps in reducing heating costs. The units are designed to generate realistic flames, creating an inviting ambiance that can be enjoyed year-round.

In terms of safety, Monessen has integrated several features into the EYF24 and EYF18. The oxygen depletion sensor (ODS) automatically shuts off the unit if oxygen levels fall below safe limits, providing peace of mind for homeowners. Additionally, the units are designed to operate quietly, allowing for an undisturbed living experience.

Customization options also abound with these models. Homeowners can select from a range of decorative media, including logs, stones, and glass, to personalize their fireplace's appearance. This flexibility ensures that each installation can be uniquely tailored to match individual tastes and home styles.

In conclusion, the Monessen Hearth EYF24 and EYF18 fireplaces are excellent choices for anyone seeking a stylish, efficient, and safe heating solution. With their modern design, vent-free technology, and user-friendly features, they offer an inviting and warm atmosphere that can enhance any home environment.