Monessen Hearth EYF24, EYF18 operating instructions Never connect unit to private

Page 4

IMPORTANT SAFETY INFORMATION

Continued from page 3

13.Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into fireplace. Do not place a blower inside burn area of firebox. Ceiling fans may create drafts that alter burner flame patterns. Sooting and improper burning will occur.

14.Caution: Candles, incense, oil lamps, etc. produce combustion by-products including soot. Vent-free appli- ances will not filter or clean soot produced by these types of products. In addition, the smoke and/or aromatics (scents) may be reburnt in the vent-free appliance which can produce odors. It is recommended to minimize the use of candles, incense, etc. while the vent-free appliance is in operation.

15.This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for ad- equate combustion and ventilation air must be provided. See page 7.

16.Keep room area clear and free from combustible materi- als, gasoline and other flammable vapors and liquids.

17.Unvented gas heaters are a supplemental zone heater. They are not intended to be a primary heating appliance. Water vapor produced by an unvented heater can create moisture problems in a home when operated for extended periods of time.

18.During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance; possibly causing headaches or eye or lung irritation. This is a normal and temporary occurrence.

The initial break-in operation should last two to three hours with the burner at the highest setting. Provide maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in period will be slight and will disappear with continued use.

19.Input ratings are shown in BTU per hour and are for elevations up to 2,000 feet. For elevations above 2,000 feet, input ratings should be reduced 4 percent for each 1,000 feet above sea level. See the National Fuel Gas Code.

20.The heater and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

21.The heater must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

22.Do not use this room heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

23.This appliance must not be used with glass doors in the closed position. This can lead to pilot outages and severe sooting outside the fireplace.

24.Never burn solid fuels in a fireplace where a unvented room heater is installed.

25.Always have a fireplace screen in place when the ap- pliance is in operation and , unless other provisions for combustion air are provided, the screen shall have an opening(s) for induction of combustion air.

This appliance may be installed in an aftermar- ket, permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

 

 

 

WARNING

Never connect unit to private

 

 

 

 

(non-utility) gas wells. This gas is

 

 

commonly known as wellhead gas.

 

 

 

We suggest that our gas hearth products be installed and serviced by professionals who are certified in the U.S. by the National Fireplace Institute® (NFI) as Gas Specialists.

www.nficertified.org

Attention Massachusetts Residents:

This product must be installed by a licensed gas fitter.

4

65D1009

Image 4
Contents Unvented GAS LOG Heater or Vented Decorative Appliance What to do if YOU Smell GASContents Installer Important Safety InformationOwner Never connect unit to private Getting Started What YOU will Need for InstallationMake Sure YOU have Received ALL Parts Natural GAS Product Features and SpecificationsPROPANE/LPG Codes General Installation InformationAdequate Combustion and Ventilation AIR Counter Fireplace L1 = 151/2 Ft., L2 = 12 Ft., W = 12 Ft., H = 8 FtFireplace and Hearth Dimensions Placement in a Fireplace with a Restrictive Barrier Depth of fireplace/fireboxClearances and Height Requirements Sidewall and Ceiling ClearancesClearances and Height Requirements Minimum Mantel Clearance With Hood Floor Clearance Minimum Clearance above Combustible FlooringInstalling Vented Applications Before Fully Installing the UnitBefore Installing the Appliance Damper Stop InstallationInstalling Vented Application Assembly ProcedurePlacing and Securing Appliance Horizontal Grate Bar Hooks for Screw Middle Hole for AnchorConnecting the GAS Flexible Tube Manual Shutoff Gas Supply Inlet ValveNPT Test Plug Checking GAS PressureTest Port OUT Connecting Optional Wall Switch or Thermostat Electrical Wiring MillivoltRequire 110 VAC to Operate Connecting Optional Remote Receiver Follow Instructions Supplied with the RemoteChecking System Operation Remote Receiver Velcro PadsLOG Placement Installing EYF24-F LOG Unit on BurnerPlacing the Decorative Rock Top Left Log Front Log Top Right Log Main Log TabsRear Log Middle Log #2 Installing EYF18-R LOG SET on UnitTop Log #4 Front Log #3 Installing EYF24-R or EYF30-R LOG SET on Unit Rear Log #1 Middle LogFront Top Right Log #4 Log #3 Top Left Log #5Flame Appearance Checking the Pilot FlameMillivolt Control Manual ControlChecking the Burner Flame Operating InstructionsFor Your Safety Read Before Lighting Piezo Ignitor SwitchOperating Instructions Control KnobsManual Control Lighting Instructions To Turn OFF HeaterOn/Off Switch Piezo Hi/Lo Control On/Off/Pilot Control Millivolt Control Lighting InstructionsCleaning and Servicing Operating Instructions and Cleaning and ServicingMatch Lighting Instructions Troubleshooting Observed Prob Possible Cause RemedyODS/pilot lights, but flame Illustrated Parts Breakdown Replacement Parts List Replacement Parts are Available Through Your RetailerEYF24-F EYF18-RCarbon Monoxide Detector Requirements Lifetime Warranty Five Year WarrantyBasic Warranty Mhsc
Related manuals
Manual 32 pages 30.22 Kb

EYF24, EYF18 specifications

The Monessen Hearth EYF24 and EYF18 represent a perfect blend of style, efficiency, and innovative technology in the world of vent-free gas fireplaces. Designed for homeowners who desire warmth and ambiance without the complexities of traditional fireplaces, these units stand out as reliable heating solutions.

The EYF24 and EYF18 are designed with a sleek and modern aesthetic, making them suitable for a variety of home decors. Their compact size allows for versatile installation options, making them ideal for both small spaces and larger living areas. With a focus on ease of use, both models come equipped with user-friendly controls, enabling homeowners to adjust the flame height and heat output effortlessly.

One of the standout features of these Monessen fireplaces is their vent-free technology. This allows the units to operate efficiently without the need for a chimney or flue, which means less installation cost and hassle. The design also facilitates greater flexibility in placement, as they can be installed in virtually any room. Whether you want to enhance a cozy den or add warmth to a larger gathering space, the EYF24 and EYF18 are adaptable to your needs.

Another notable characteristic is their high-efficiency rating. Both models utilize advanced burner technology that maximizes heat output while minimizing energy consumption. This capability not only ensures a comfortable indoor environment but also helps in reducing heating costs. The units are designed to generate realistic flames, creating an inviting ambiance that can be enjoyed year-round.

In terms of safety, Monessen has integrated several features into the EYF24 and EYF18. The oxygen depletion sensor (ODS) automatically shuts off the unit if oxygen levels fall below safe limits, providing peace of mind for homeowners. Additionally, the units are designed to operate quietly, allowing for an undisturbed living experience.

Customization options also abound with these models. Homeowners can select from a range of decorative media, including logs, stones, and glass, to personalize their fireplace's appearance. This flexibility ensures that each installation can be uniquely tailored to match individual tastes and home styles.

In conclusion, the Monessen Hearth EYF24 and EYF18 fireplaces are excellent choices for anyone seeking a stylish, efficient, and safe heating solution. With their modern design, vent-free technology, and user-friendly features, they offer an inviting and warm atmosphere that can enhance any home environment.