Monessen Hearth CFX32 LOG & Rockwool Placement, Proper installation sequence, Place rock wool

Page 21

LOG & ROCKWOOL PLACEMENT

CFX Vent Free Fireplace System

Proper installation sequence

Rear Log

#3

(CFX32)

 

Figure 19

 

1.

Install front right log (#1) on two pins on right Left Middle

 

side of burner.

Log #5

2.

Install left front log (#2) on two pins on left side

 

 

of burner.

 

3.

Install back log (#3) on back of burner.

 

4.

Install right middle log (#4) on two pins on

 

 

burner. Rest right end of right middle log on

Left Front

 

the right front log.

Log #2

5. Install left middle log (#5) on two pins on burner. Rest left end of left middle log on left front log.

Pins

Pins

Figure 19 -

Log Placement CFX32

Right Middle Log #4

Right Front Log #1

Pins

Pins

LG589

Place rock wool

After installing logs, pull apart dime-size pieces of rock wool. Place rock wool evenly over burner ports. Wash hands after installing rock wool. Itching may occur.

Dime Size Rock

Wool

CAUTION

Use only rock wool provided with log set.

Do not add additional rock wool.

Place rock wool on burner ports only.

Keep air gap between rear log and burner

CLEAN.

Figure 20 -

Rockwool Installation

LG590

20301726

21

Image 21
Contents What to do if YOU Smell GAS Vent-free Fireplace Systems Models CFX24, CFX32CFX Vent Free Fireplace System ContentsImportant Safety Information InstallerOwner Codes Important Safety InformationGas Specifications Product Features & specificationsOperation GAS pressuresCFX24 CFX32 Fireplace & System DimensionsHandle with care Getting StartedAdequate Combustion and Ventilation AIR Do not Install the CFX Model in a Bedroom or Bathroom Fireplace InstallationClearances and Height Requirements Remove Screen General Installation InformationInstall Mantel Firebox to Mantel Installation General Installation Information Install Optional Firebrick PanelsInstallation Items Needed Installing gas piping to fireplace / burner system locationConnect the GAS Check gas typeConnect the GAS Check GAS Pressure Connecting Optional Wall Switch or Thermostat Electrical Wiring Milli-voltCheck System Operation Connect Remote ReceiverProper installation sequence CFX24 LOG PlacementProper installation sequence LOG & Rockwool PlacementClean CFX32Flame appearance Check the pilot flameCorrect log flame appearance Operating Instructions Check the Burner FlameOperating Instructions What to do if YOU Smell GASMILLI-VOLT Control Lighting Instructions Match Lighting Instructions Cleaning and ServicingOptional Equipment Blower and Other Optional EquipmentForced Air Kit FirebricksObserved Problem Possible Cause Remedy TroubleshootingTroubleshooting CFX24 CFX32 Replacement PartsReplacement Parts Replacment Parts Replacement Parts are Available Through Your RetailerCFX Vent Free Fireplace System CFX Vent Free Fireplace System Five Year Warranty Lifetime WarrantyBasic Warranty If Warranty Service is NeededMhsc