Napoleon Fireplaces EPA 1100 Stove Installation, Installing the Legs, Alcove Installation

Page 5
FIGURE 2A

5

STOVE INSTALLATION

INSTALLING THE LEGS

To avoid being damaged during shipping, the stove has been bolted to the pallet and must be unbolted before the stove can be installed.

1.Remove the 4 nuts and washers from the underside of the pallet.

2. Lift the stove up and away from the pallet to clear the threaded studs sticking through the pallet. Place the stove on its back onto a protective surface such as a carpet or blan- ket to avoid scratches dur- ing leg installation.

FIGURE 2B

3.Remove the four additional nuts from each of the four studs.

4.Use four of the nuts and washers removed above to install the legs as illustrated in FIGURES 2a & 2b.

5.Lift the stove up and gently set down on all four legs. Do not pivot unit up on its legs, as this could result in damage to the legs.

ALCOVE INSTALLATION

Model 1100 only may be installed, using a listed double wall connector, such as Security DL6 in Canada, the Simpson Duravent Plus DVL in the USA or an equiva- lent double wall connector, into an alcove having a depth of no more than 4 feet and a height of at least 7 feet. The minimum clearances are as shown in FIGURE 3.

9"

6"

 

 

14"

4 FOOT

 

MAX.

 

 

 

23"

 

ALCOVE

 

STOVE INSTALLATION

If the stove is to be installed on a combustible floor, it must be placed on a approved non-com- bustible hearth pad, that extends 8" (200mm) beyond the stove sides and back, and 18" (455mm)

to the front.

FIGURE 4A

FIGURE 4B

 

 

 

 

 

 

SINGLE WALL CHIMNEY CONNECTOR*

 

 

1100/1100L

1400/1400L

 

1900

 

A

12"

(305mm)

12"

(305mm)

22"

(560mm)

 

B

10"

(254mm)

12"

(305mm)

12"

(305mm)

 

 

 

 

 

 

 

 

 

C

6"

(152mm)

6"

(152mm)

8"

(205mm)

 

 

DOUBLE WALL CHIMNEY CONNECTOR

 

 

1100/1100L

1400/1400L

 

1900

 

A

10"

(254mm)

10"

(254mm)

22"

(560mm)

 

B

6"

(152mm)

6"

(152mm)

12"

(305mm)

 

 

 

 

 

 

 

 

 

C

2"

(50mm)

4"

(102mm)

8"

(205mm)

*CLEARANCES CAN BE REDUCED WITH SHIELDING ACCEPTABLE TO LOCAL AUTHORITIES.

CHIMNEY CONNECTION

Vent the stove into a masonry chimney or an approved, insulated solid-fuel stainless-steel chimney with as short and straight a length of six-inch (150mm) diameter smoke pipe as possible. Connection to a masonry chim- ney must be by a metal or masonry thimble cemented in place. An insulated stainless steel chimney must be supported at the ceiling or roof and its installation must comply with its manufacturer's instructions.

THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40% OF THE CHIMNEY HEIGHT ABOVE THE STOVE.

All horizontal smoke pipe must slope slightly upwards a minimum of 1/4" per foot (6mm/ 0.3m) and all connections must be tight and secured by three sheet metal screws equally spaced.

An uninsulated smoke pipe shall not pass through an attic, roof space, closet or similar concealed space, or through a floor, ceiling, wall or partition, or any combustible construc- tion.

FIGURE 3

W415-0360 / 11.05.02

Image 5
Contents EPA 1100, 1100L, 1100C, 1400, 1400L EPI 1101 For Your SafetyConditions and Limitations Napoleon Wood Fireplace Presidents Lifetime Limited WarrantyTable of Contents General Information IntroductionCare of ALL Plated Enamelled Parts Care of GlassInstalling the Legs Stove InstallationAlcove Installation Stove InstallationAdding Chimney Sections Mobile Home InstallationVenting Pedestal Models Outside AIRHint for Installing Porcelain Enamel Inserts InstallationPrior to Installation Installation Into a Masonry FireplaceInsert Model Installation Into a Factory Built FireplaceInsert Models FAN Service or Replacement Back SizesSides TOPPedestal Trim Installation Ornamental Trivet InstallationFire Extinguishers / Smoke Detectors Achieving Proper DraftFuel Loading and Burn Cycle Flash FireSolutions ASH Removal ProceduresGasket Replacement Door Removal 1100C only SmokingDonts DOSAccessories / Options Replacement Parts5758