5
STOVE INSTALLATION
INSTALLING THE LEGS
To avoid being damaged during shipping, the stove has been bolted to the pallet and must be unbolted before the stove can be installed.
1.Remove the 4 nuts and washers from the underside of the pallet.
2. Lift the stove up and away from the pallet to clear the threaded studs sticking through the pallet. Place the stove on its back onto a protective surface such as a carpet or blan- ket to avoid scratches dur- ing leg installation.
FIGURE 2B
3.Remove the four additional nuts from each of the four studs.
4.Use four of the nuts and washers removed above to install the legs as illustrated in FIGURES 2a & 2b.
5.Lift the stove up and gently set down on all four legs. Do not pivot unit up on its legs, as this could result in damage to the legs.
ALCOVE INSTALLATION
Model 1100 only may be installed, using a listed double wall connector, such as Security DL6 in Canada, the Simpson Duravent Plus DVL in the USA or an equiva- lent double wall connector, into an alcove having a depth of no more than 4 feet and a height of at least 7 feet. The minimum clearances are as shown in FIGURE 3.
9" | 6" |
|
| 14" | 4 FOOT |
| MAX. | |
|
| |
| 23" |
|
ALCOVE |
|
STOVE INSTALLATION
If the stove is to be installed on a combustible floor, it must be placed on a approved
to the front. | FIGURE 4A |
FIGURE 4B |
|
|
|
| |||
|
| SINGLE WALL CHIMNEY CONNECTOR* | |||||
|
| 1100/1100L | 1400/1400L |
| 1900 | ||
| A | 12" | (305mm) | 12" | (305mm) | 22" | (560mm) |
| B | 10" | (254mm) | 12" | (305mm) | 12" | (305mm) |
|
|
|
|
|
|
|
|
| C | 6" | (152mm) | 6" | (152mm) | 8" | (205mm) |
|
| DOUBLE WALL CHIMNEY CONNECTOR | |||||
|
| 1100/1100L | 1400/1400L |
| 1900 | ||
| A | 10" | (254mm) | 10" | (254mm) | 22" | (560mm) |
| B | 6" | (152mm) | 6" | (152mm) | 12" | (305mm) |
|
|
|
|
|
|
|
|
| C | 2" | (50mm) | 4" | (102mm) | 8" | (205mm) |
*CLEARANCES CAN BE REDUCED WITH SHIELDING ACCEPTABLE TO LOCAL AUTHORITIES.
CHIMNEY CONNECTION
Vent the stove into a masonry chimney or an approved, insulated
THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40% OF THE CHIMNEY HEIGHT ABOVE THE STOVE.
All horizontal smoke pipe must slope slightly upwards a minimum of 1/4" per foot (6mm/ 0.3m) and all connections must be tight and secured by three sheet metal screws equally spaced.
An uninsulated smoke pipe shall not pass through an attic, roof space, closet or similar concealed space, or through a floor, ceiling, wall or partition, or any combustible construc- tion.
FIGURE 3