Napoleon Fireplaces GD82NT manual Installation Wall and Ceiling Protection, Vertical Installation

Page 11
VENT
PIPE
COLLAR
figure 14

11

INSTALLATION

WALL AND CEILING PROTECTION

For optimum performance it is recommended that all horizontal runs have a minimum ¼ inch rise per foot using

flexible venting.

For safe and proper operation of the fireplace, follow the venting instructions exactly.

Horizontal Termination: A clearance to combustibles of 2" must be maintained during the first 24” of vent- ing when pentrating combustible walls. The firestop spacer (W500-0292) supplied with the unit should be used to maintain this clearance. The first two feet of outer 7” diameter vent pipe, from the appliance must be wrapped in the 1 inch thick insulation sleeve (supplied) as well as having a 1 inch air gap. Thereafter a 1” clearance to com- bustibles may be maintained using firestop spacer (W615-0044 for use with flexible venting or rigid venting.)

VERTICAL INSTALLATION

 

 

This application occurs

 

 

when venting through

 

figure 13

a roof. Installation kits

 

 

for various roof pitches

 

 

are available from your

 

11

Napoleon dealer. See

11

Accessories to order the

 

 

 

 

specific kit required.

1. Determine the air

terminal location, cut

and frame 9½ or 11½

inch openings in the ceil- ing and the roof to provide the minimum clearance between the fireplace pipe / liner and any combustible material. Try to center the exhaust pipe location midway between two joist to prevent having to cut them. Use a plumb bob to line up the center of the openings.

do not fill this space with any type of material. A vent pipe shield will prevent any materi- als such as insulation, from filling up the 1" air space around the pipe. Nail headers between

the joist for extra sup- port.

2.Apply a bead of

caulking (not supplied) to the framework or to the Wolf Steel vent pipe shield plate or equivalent (in the case of a finished ceiling), and secure over the opening in the ceiling. A firestop must be placed on the bottom of each framed opening in a roof or ceiling that the venting system passes through. Apply a bead of caulking all around and place a firestop spacer over the vent shield to restrict cold air from being drawn into the room or around the fireplace. Ensure that both spacer and shield maintain the required clearance to combustibles. Once the vent pipe / liner is installed

in its final position, apply sealant

between the pipe / liner and the firestop spacer.

HORIZONTAL INSTALLATION

This application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum rectangle opening of 12” x 11”.

IMPORTANT: For optimum performance, The stove pipe should rise ¼” per foot of run.

1.Assemble the shield to the spacer as shown, using the 3 shorter screws supplied.

The shield is meant to protect combustible materials within the wall. If the shield is deeper than the combustible portion of the wall, cut to fit.

2.Apply a bead of caulking all around and place the firestop spacer over the framework to restrict cold air from being drawn into the room or around the stove. Ensure that both spacer and shield maintain the required clearance to combustibles. Secure the spacer in place using the 4 longer screws sup- plied. Once the vent pipe is installed in its final position, apply sealant between the pipe and the firestop spacer.

3.In the attic, after the pipe / liner has been installed, slide the vent pipe collar down to cover up the open end of the shield and tighten. This will prevent any materials, such as insulation, from filling up the 1" air space around the pipe.

VENT PIPE

SHIELD

FIGURE 15

W415-0536 / C / 09.06.06

Image 11
Contents W415-0536 / C What to do if YOU Smell GAS Table of Contents Napoleon gas fireplace president’s lifetime limited warranty 21 3/4 to top of fireplace opening General instructionsGeneral inFORMATION 37 5/8 17 3/4 DIA 21 22 1/8 13 7Supplier VENTINGCare of glass, and plated parts Formula 1 HT VT Formula 2 HT + VT 40 feet Example TOP Exit / horizontal terminationDefinitions Elbow Vent Length ValuesFormula 2 HT + VT 24.75 feet Formula HT 4.2 VT10.7 Formula HT + VT 24.75 feet 6.7Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example TOP Exit Vertical terminationTOP Vertical termination Formula 1 HT VT Formula 2 HT + VT 40 feetW415-0536 / C Horizontal Installation Installation Wall and Ceiling ProtectionVertical Installation Through the attic Using Flexible Vent ComponentsHorizontal AIR Terminal Installation Vertical AIR Terminal InstallationFireplace Vent Connection Using Rigid Vent ComponentsExtended Horizontal AIR Terminal Installation Use open flame Vertical Venting InstallationGAS Installation Restricting Vertical VentsClearance to Combustibles FramingElectrical Connection Hard Wiring ConnectionSchematic It is necessary to hard wire this fireplaceLog Shipping Bracket Log PlacementFinishing Door RemovalFirebox must be sealed Blower ReplacementNight Light Replacement Turn off the power to the fireplaceStep Decorative Brick Panel InstallationAfk / wi face kit installation 1a. Rectangular Front Removal REMOTE, Receiver and Valve AccessBurner assembly removal Hand Held Remote Operations Operation / MaintenanceTime OUT Fireplace OperationFAN Speed Setting Address Setting Procedure Dip switch number 0 = on / 1 = off Lighting Instructions For Your Safety Read BeforeOperating Instructions What to do if YOU Smell GASVenturi Adjustment AdjustmentsMaintenance Pilot Burner AdjustmentTerminal Kits ReplacementsReplacement Parts Accessories000 Symptom Problem Test Solution Trouble Shooting GuideShorten wire to correct length or wire gauge Pilot burning no Themostat or switch is deCheck that the wire is connected to the push button ignitor Replace the wire if the wire insulation is broken or frayedFireplace Service History W415-0536 / C W415-0536 / C

GD82PT, GD82NT specifications

Napoleon Fireplaces has long been recognized for its exceptional quality and innovative designs in the world of home heating. Among its impressive lineup are the GD82PT and GD82NT gas fireplaces, two models that stand out for their remarkable features and technologies. These fireplaces provide an ideal combination of aesthetic appeal and functional performance, making them a popular choice for modern homes.

Both the GD82PT and GD82NT are direct vent gas fireplaces, meaning they efficiently draw air from the outside for combustion and exhaust the leftover gases outside, ensuring optimal indoor air quality. This system allows them to be installed in a variety of locations without the need for a traditional chimney, providing flexibility in design and placement.

One of the key features of these models is their large viewing area, which is enhanced by a minimalist design that eliminates bulky frames. This offers an unobstructed view of the mesmerizing flames, turning the fireplace into a stunning focal point in any room. Additionally, both models boast an impressive heating capacity, ensuring that they efficiently warm up spaces even in the coldest climates.

The GD82PT model comes with a traditional logset and ember bed, creating a classic look that many homeowners desire. It is designed to accommodate a 35,000 BTU input, providing substantial heat while still being energy efficient. The GD82NT, on the other hand, features a contemporary linear design, which appeals to those looking for a modern aesthetic in their living spaces. This model also includes a unique glass media option that allows for a sleek and stylish appearance.

Both fireplaces feature Napoleon's advanced electronic ignition system, which ensures a reliable startup every time. Furthermore, the built-in remote control allows users to adjust heat output and flame height with ease. These models are also equipped with a variable speed blower, enhancing heat circulation throughout the room, making them not only visually appealing but highly functional as well.

Safety is another priority for Napoleon. Both models come with a safety screen barrier, preventing accidental contact with the hot glass surface. The intelligent gas control system also includes an oxygen depletion sensor, automatically shutting off the gas supply if oxygen levels drop to unsafe levels.

In summary, the Napoleon GD82PT and GD82NT gas fireplaces exemplify cutting-edge technology and elegant design, providing warmth and ambience to any space. With their innovative features, customizable options, and a strong commitment to safety, these models represent the pinnacle of modern fireplace design.