Napoleon Fireplaces GD82NT, GD82PT manual Table of Contents

Page 3

TABLE of CONTENTS

PG2-6 introduction

Warnings and Safety Precautions

Warranty

Dimensions

General Instructions

General Information

Care of Glass & Plated Parts

6-10 venting

Vent lengths

Venting Specifications

Air Terminal Locations

11-16 INSTALLATION/FRAMING

Wall & Ceiling Protection

Using Flexible Vent Components

Fireplace Vent Connection

Using Rigid Vent Components

Gas Installation

Restricting Vertical Vents

Framing

Clearance to Combustibles

Mantle Clearances and Enclosures

16 ELECTRICAL CONNECTION

Hard Wiring Connections

Schematic

17 finishing

Door Removal

Log Shipping Bracket

Log Placement

Glowing Embers

18 Blower REPLACEMENT

Night Light Replacement

19DECORATIVE BRICK PANEL INSTALLATION

20AFK / WI FACE KIT INSTALLATION

21REMOTE AND VALVE ACCESS

Burner Assembly Removal

22-27 OPERATION / MAINTENANCE

Fireplace Operation

Hand Held Remote Operation

Operating Instructions

27 adjustments

Pilot Burner Adjustment

Venturi Adjustment

28-29 REPLACEMENTS

Ordering Replacement Parts

Replacement Parts

Terminal Kits

Vent Kits

Accessories

20-31 Trouble Shooting Guide

PLEASE RETAIN THIS MANUAL for future reference

warning

Do not burn wood or other materials in this fireplace.

Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Keep young children and animals away when the fireplace is hot.

Due to high temperatures, the fireplace should be located out of traffic and away from furniture and draperies.

Clothing or other flammable material should not be placed on or near the fireplace.

Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace.

It is imperative that the control compartments, burners and circulating blower and its passageway in the fireplace and venting system are kept clean. The fireplace and its venting system should be inspected before use and at least annu- ally by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. The fireplace area must be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids.

Under no circumstances should this fireplace be modified.

This fireplace must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance.

Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

Do not operate the fireplace with the glass door removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.

Do not strike or slam shut the fireplace glass door.

This fireplace uses and requires a fast acting thermocouple. Replace only with a fast acting thermocouple supplied by

Wolf Steel Ltd.

note: Changes, other than editorial, are denoted by a vertical line in the margin.

W415-0536 / C / 09.06.06

Image 3
Contents W415-0536 / C What to do if YOU Smell GAS Table of Contents Napoleon gas fireplace president’s lifetime limited warranty 21 3/4 to top of fireplace opening General instructionsGeneral inFORMATION 37 5/8 17 3/4 DIA 21 22 1/8 13 7VENTING Care of glass, and plated partsSupplier Formula 1 HT VT Formula 2 HT + VT 40 feet Example TOP Exit / horizontal terminationDefinitions Elbow Vent Length ValuesFormula 2 HT + VT 24.75 feet Formula HT 4.2 VT10.7 Formula HT + VT 24.75 feet 6.7Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example TOP Exit Vertical terminationTOP Vertical termination Formula 1 HT VT Formula 2 HT + VT 40 feetW415-0536 / C Installation Wall and Ceiling Protection Vertical InstallationHorizontal Installation Through the attic Using Flexible Vent ComponentsHorizontal AIR Terminal Installation Vertical AIR Terminal InstallationUsing Rigid Vent Components Extended Horizontal AIR Terminal InstallationFireplace Vent Connection Use open flame Vertical Venting InstallationGAS Installation Restricting Vertical VentsClearance to Combustibles FramingElectrical Connection Hard Wiring ConnectionSchematic It is necessary to hard wire this fireplaceLog Shipping Bracket Log PlacementFinishing Door RemovalFirebox must be sealed Blower ReplacementNight Light Replacement Turn off the power to the fireplaceStep Decorative Brick Panel InstallationAfk / wi face kit installation REMOTE, Receiver and Valve Access Burner assembly removal1a. Rectangular Front Removal Hand Held Remote Operations Operation / MaintenanceTime OUT Fireplace OperationFAN Speed Setting Address Setting Procedure Dip switch number 0 = on / 1 = off Lighting Instructions For Your Safety Read BeforeOperating Instructions What to do if YOU Smell GASVenturi Adjustment AdjustmentsMaintenance Pilot Burner AdjustmentTerminal Kits ReplacementsReplacement Parts Accessories000 Symptom Problem Test Solution Trouble Shooting GuideShorten wire to correct length or wire gauge Pilot burning no Themostat or switch is deCheck that the wire is connected to the push button ignitor Replace the wire if the wire insulation is broken or frayedFireplace Service History W415-0536 / C W415-0536 / C

GD82PT, GD82NT specifications

Napoleon Fireplaces has long been recognized for its exceptional quality and innovative designs in the world of home heating. Among its impressive lineup are the GD82PT and GD82NT gas fireplaces, two models that stand out for their remarkable features and technologies. These fireplaces provide an ideal combination of aesthetic appeal and functional performance, making them a popular choice for modern homes.

Both the GD82PT and GD82NT are direct vent gas fireplaces, meaning they efficiently draw air from the outside for combustion and exhaust the leftover gases outside, ensuring optimal indoor air quality. This system allows them to be installed in a variety of locations without the need for a traditional chimney, providing flexibility in design and placement.

One of the key features of these models is their large viewing area, which is enhanced by a minimalist design that eliminates bulky frames. This offers an unobstructed view of the mesmerizing flames, turning the fireplace into a stunning focal point in any room. Additionally, both models boast an impressive heating capacity, ensuring that they efficiently warm up spaces even in the coldest climates.

The GD82PT model comes with a traditional logset and ember bed, creating a classic look that many homeowners desire. It is designed to accommodate a 35,000 BTU input, providing substantial heat while still being energy efficient. The GD82NT, on the other hand, features a contemporary linear design, which appeals to those looking for a modern aesthetic in their living spaces. This model also includes a unique glass media option that allows for a sleek and stylish appearance.

Both fireplaces feature Napoleon's advanced electronic ignition system, which ensures a reliable startup every time. Furthermore, the built-in remote control allows users to adjust heat output and flame height with ease. These models are also equipped with a variable speed blower, enhancing heat circulation throughout the room, making them not only visually appealing but highly functional as well.

Safety is another priority for Napoleon. Both models come with a safety screen barrier, preventing accidental contact with the hot glass surface. The intelligent gas control system also includes an oxygen depletion sensor, automatically shutting off the gas supply if oxygen levels drop to unsafe levels.

In summary, the Napoleon GD82PT and GD82NT gas fireplaces exemplify cutting-edge technology and elegant design, providing warmth and ambience to any space. With their innovative features, customizable options, and a strong commitment to safety, these models represent the pinnacle of modern fireplace design.