FIREPLACE VENT CONNECTION

1.Install the 4” diameter aluminium flexible liner to the fireplace. Secure with 3 screws and flat washers. Seal the joint and screw holes using the high temperature sealant (W573-0007 not provided).

2.Install the 7” diameter aluminium flexible liner to the fireplace. Attach and seal the joints.

figure 20

USING RIGID VENT COMPONENTS

The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Wolf Steel vent spacers or equivalent every 3 feet and either side of each elbow to maintain the minimum 1¼” clearance between the outer and inner vent pipes. Use Wolf Steel support ring as- sembly or equivalent noncombustible strapping to maintain the minimum clearance to combustibles for both vertical and horizontal runs.

All inner exhaust and outer intake vent pipe joists may be sealed using either Red RTV high temp silicone sealant or Black high temp Mill Pac with the exception of the fireplace exhaust flue collar which must be sealed using Mill Pac (not supplied).

HORIZONTAL AIR TERMINAL INSTALLATION

1. Move the fire-

 

FIGURE 21

place into position.

 

CAULKING

#10x2½"

 

Measure the vent

 

SCREWS

CAULKING

length required

 

 

7" PIPE

between terminal

 

4" PIPE

 

 

and fireplace tak-

 

2" OVERLAP

ing into account

 

HI-TEMP

the additional

 

SEALANT

 

 

length needed for

 

HI-TEMP

 

SEALANT

the finished wall

 

 

surface and any

 

 

1¼” overlaps between venting components.

2.Apply high temperature sealant (W573-0007 not pro- vided) to the outer edge of the 4” inner collar of the fireplace. Attach the first vent component and secure using 3 self tapping screws. Repeat using 7” piping.

3.Holding the air terminal (with the air deflectors to the top and the lettering in an upright, readable position) insert the terminal into both vent pipes with a twisting motion to ensure that both the terminal sleeves engage into the vent pipes and sealant. Secure the terminal to the exterior wall and

make weather tight by sealing with caulking (not supplied).

EXTENDED HORIZONTAL AIR TERMINAL

INSTALLATION

1. Follow the instructions for “Horizontal Air Terminal Installations”, items 1 to 3.

2. Continue adding com- ponents alternating inner and outer venting. Ensure

that all 4” venting and elbows

have sufficient vent spacers attached and each compo- nent is securely fastened to the one prior. Attach the 4” telescopic sleeve to the vent run.

Repeat using a 7” telescopic sleeve. Secure and seal as before. To facilitate completion, attach 4” and 7” couplers to the air terminal.

3.Install the air terminal. See item 3 of the Horizontal Air

Terminal Installation. Extend the 4” telescopic sleeve; con- nect to the air terminal assembly. Fasten with self tapping screws and seal. Repeat using the 7” telescopic sleeve.

W415-0536 / C / 09.06.06

Image 13
Contents W415-0536 / C What to do if YOU Smell GAS Table of Contents Napoleon gas fireplace president’s lifetime limited warranty General inFORMATION General instructions37 5/8 17 3/4 DIA 21 22 1/8 13 7 21 3/4 to top of fireplace openingCare of glass, and plated parts VENTINGSupplier Definitions TOP Exit / horizontal terminationElbow Vent Length Values Formula 1 HT VT Formula 2 HT + VT 40 feet Example10.7 Formula HT 4.2 VTFormula HT + VT 24.75 feet 6.7 Formula 2 HT + VT 24.75 feetTOP Vertical termination TOP Exit Vertical terminationFormula 1 HT VT Formula 2 HT + VT 40 feet Formula 1 HT 3VT Formula 2 HT + VT 40 feet ExampleW415-0536 / C Vertical Installation Installation Wall and Ceiling ProtectionHorizontal Installation Horizontal AIR Terminal Installation Using Flexible Vent ComponentsVertical AIR Terminal Installation Through the atticExtended Horizontal AIR Terminal Installation Using Rigid Vent ComponentsFireplace Vent Connection GAS Installation Vertical Venting InstallationRestricting Vertical Vents Use open flameClearance to Combustibles FramingSchematic Hard Wiring ConnectionIt is necessary to hard wire this fireplace Electrical ConnectionFinishing Log PlacementDoor Removal Log Shipping BracketNight Light Replacement Blower ReplacementTurn off the power to the fireplace Firebox must be sealedStep Decorative Brick Panel InstallationAfk / wi face kit installation Burner assembly removal REMOTE, Receiver and Valve Access1a. Rectangular Front Removal Time OUT Operation / MaintenanceFireplace Operation Hand Held Remote OperationsFAN Speed Setting Address Setting Procedure Dip switch number 0 = on / 1 = off Operating Instructions For Your Safety Read BeforeWhat to do if YOU Smell GAS Lighting InstructionsMaintenance AdjustmentsPilot Burner Adjustment Venturi AdjustmentReplacement Parts ReplacementsAccessories Terminal Kits000 Symptom Problem Test Solution Trouble Shooting GuideCheck that the wire is connected to the push button ignitor Pilot burning no Themostat or switch is deReplace the wire if the wire insulation is broken or frayed Shorten wire to correct length or wire gaugeFireplace Service History W415-0536 / C W415-0536 / C

GD82PT, GD82NT specifications

Napoleon Fireplaces has long been recognized for its exceptional quality and innovative designs in the world of home heating. Among its impressive lineup are the GD82PT and GD82NT gas fireplaces, two models that stand out for their remarkable features and technologies. These fireplaces provide an ideal combination of aesthetic appeal and functional performance, making them a popular choice for modern homes.

Both the GD82PT and GD82NT are direct vent gas fireplaces, meaning they efficiently draw air from the outside for combustion and exhaust the leftover gases outside, ensuring optimal indoor air quality. This system allows them to be installed in a variety of locations without the need for a traditional chimney, providing flexibility in design and placement.

One of the key features of these models is their large viewing area, which is enhanced by a minimalist design that eliminates bulky frames. This offers an unobstructed view of the mesmerizing flames, turning the fireplace into a stunning focal point in any room. Additionally, both models boast an impressive heating capacity, ensuring that they efficiently warm up spaces even in the coldest climates.

The GD82PT model comes with a traditional logset and ember bed, creating a classic look that many homeowners desire. It is designed to accommodate a 35,000 BTU input, providing substantial heat while still being energy efficient. The GD82NT, on the other hand, features a contemporary linear design, which appeals to those looking for a modern aesthetic in their living spaces. This model also includes a unique glass media option that allows for a sleek and stylish appearance.

Both fireplaces feature Napoleon's advanced electronic ignition system, which ensures a reliable startup every time. Furthermore, the built-in remote control allows users to adjust heat output and flame height with ease. These models are also equipped with a variable speed blower, enhancing heat circulation throughout the room, making them not only visually appealing but highly functional as well.

Safety is another priority for Napoleon. Both models come with a safety screen barrier, preventing accidental contact with the hot glass surface. The intelligent gas control system also includes an oxygen depletion sensor, automatically shutting off the gas supply if oxygen levels drop to unsafe levels.

In summary, the Napoleon GD82PT and GD82NT gas fireplaces exemplify cutting-edge technology and elegant design, providing warmth and ambience to any space. With their innovative features, customizable options, and a strong commitment to safety, these models represent the pinnacle of modern fireplace design.