When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condi- tion caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again.

After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. In both cases, open a window to sufficiently ventilate the room.

Purge the gas line with the glass door removed. As- sure that a continuous gas flow is at the burner before re-installing the door.

FOR YOUR SAFETY READ BEFORE LIGHTING:

A. This fireplace is equipped with a pilot which must be lit by hand while following these instructions exactly.

B. Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor

C. Use only your hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D. Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control system and any gas control which has been under water.

WHAT TO DO IF YOU SMELL GAS

Turn off all gas to the fireplace.

Open windows.

Do not try to light any appliance.

Do not touch any electric switch; do

not use any phone in your building.

GAS KNOB

Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire de-

partment.

OL

 

 

 

F

HI

O

 

F

 

OL

P

 

 

 

 

 

TOLIP

LIGHTING INSTRUCTIONS

WARNING: The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermocou- ple has cooled. Allow approximately 60 seconds for the thermocouple to cool.

When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed slightly.

1.Stop! Read the above safety information on this label.

2.Turn off all electric power to the fireplace.

3.Turn the gas knob clockwise to off.

4.Wait five (5) minutes to clear out any gas. If you smell gas including near the floor. Stop! Follow "B" in the above safety information on this label. If you don't smell gas go the next step.

5.Turn gas knob counter-clockwise to pilot.

6.Depress slightly and hold gas knob while lighting the pilot with the push button ignitor. Keep knob depressed for one minute, then release. If pilot does not continue to burn, repeat steps 3 through 5.

7.With pilot lit, depress and turn gas knob counter-clock-

wise to on.

8.If equipped with remote on-off switch/thermostat, main burner may not come on when you turn valve to on. Remote switch must be in the on position to ignite burner.

9.Turn on all electric power to the fireplace.

TO TURN OFF GAS

1.Turn off all electric power to the fireplace if service is 2. Push in gas control knob slightly and turn clock-

to be performed.

wise

to off. Do not force.

MAINTENANCE

Turn off the gas and electrical power before servicing the fireplace.

CAUTION: Label all wires prior to disconnection when serv- icing controls. Wiring errors can cause improper and dan- gerous operation. Verify proper operation after servicing. This fireplace and its venting system should be inspected before use and at least annually by a qualified service person. The fireplace area must be kept clear and free of combustible materials, gasoline or other flammable va- pours and liquids. The flow of combustion and ventilation air must not be obstructed.

1.In order to properly clean the burner and pilot assembly, remove the logs to expose both assemblies.

2.Keep the control compartment, logs, burner, air shutter opening and the area surrounding the logs clean by vacu- uming or brushing, at least once a year.

3.Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burn- ing properly.

4.Check to see that the pilot flame is large enough to engulf the thermocouple and thermopile and reaches to- ward the burner with the third jet.

5.Replace the cleaned logs.

6.Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5 to

10second total light-up period is satisfactory. If ignition takes longer, consult your Napoleon dealer / distributor.

7.Check that the gasketing on the sides, top and bottom of the door is not broken or missing. Replace if necessary.

W415-0381 / C / 05.13.04

Image 23
Contents Direct Vent Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Care of GLASS, and Plated Parts General InstructionsGeneral Information Venting Lengths VentingAIR Terminal Installations Special Vent Installations Typical Vent InstallationsHorizontal Termination Vertical Venting Application Flow ChartElbow Vent Length Values Horizontal TerminationDefinitions Formula 1 HT 4.2 VT Formula 2 HT + VT 24.75 feet Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Vertical Installation Horizontal Installation Installation Wall and Ceiling ProtectionVertical AIR Terminal Installation Using Flexible Vent ComponentsFireplace Vent Connection Using Rigid Vent ComponentsRestricting Vertical Vents Vertical Venting InstallationGAS Installation Framing Mobile Home InstallationMantle Installation Nailing TAB InstallationPorcelain Reflective Panels GDL42 Louvre Installation Logo PlacementL42 Louvre Installation FinishingCharcoal Lumps Charcoal EmbersVermiculite Optional Blower Installation GD36 Thermostatic Sensor Control Optional FAN InstallationOperating Instructions Operation / MaintenanceMaintenance Venturi Adjustment AdjustmentsPilot Burner Adjustment Accessories ReplacementsReplacement Parts W415-0381 / C Symptom Problem Test Solution Trouble Shooting GuideDo not Clean Glass When HOT

BGDV42P, BGDV42N specifications

Napoleon Fireplaces has long been synonymous with quality and innovation in the heating and home comfort space. Among their impressive lineup, the BGDV42N and BGDV42P gas fireplaces stand out as exceptional options that combine aesthetic appeal with advanced technology. Designed to meet various needs, these models enhance any living space while providing efficient warmth.

The BGDV42N and BGDV42P feature a large, realistic flame pattern that creates a comforting ambiance. With a viewing area that significantly improves the overall visual impact, users can enjoy a spectacular fire display, making these models perfect for both modern and traditional homes. The glass front design ensures optimal heat retention and efficiency, allowing homeowners to relish in both style and functionality.

Both models operate with unrivaled efficiency, employing innovative technologies such as the advanced variable speed blower. This feature enhances heat distribution throughout the room, ensuring that warmth reaches every corner. Furthermore, their electronic ignition with battery backup ensures dependable performance even during power outages, making them practical choices for any season.

The BGDV42N and BGDV42P come equipped with Napoleon's patented NIGHT LIGHT technology, providing ambient illumination even when the fireplace is turned off. This feature adds versatility, allowing homeowners to create a welcoming atmosphere at any time. The fireplaces also include a choice of decorative media options such as modern crystals or traditional logs, enabling users to customize the appearance to match their personal style.

Safety and ease of use are paramount, and both models offer a range of convenient controls. The remote control allows homeowners to adjust the flame height and temperature with ease, while the built-in safety features, including a glass front that remains cool to the touch, ensure peace of mind during use.

With their combination of beautiful design, advanced technology, and reliable performance, the Napoleon BGDV42N and BGDV42P gas fireplaces represent the pinnacle of modern heating solutions. Whether you seek to upgrade an existing space or create an inviting new focal point, these models provide an ideal solution for comfort and style. Embrace the warmth and elegance that Napoleon Fireplaces offers and transform your living area into a cozy retreat.