Napoleon Fireplaces BGDV42P, BGDV42N manual Using Rigid Vent Components, Fireplace Vent Connection

Page 15
W415-0381 / C / 05.13.04
FIGURE 27

5.Remove nails from the shingles, above and to the sides of the chimney. Place the flashing over the air termi- nal and slide it underneath the sides and upper edge of the shingles. Ensure that the air terminal is properly cen- tred within the flashing, giving a 3/4" margin all around. Fasten to the roof. Do not nail through the lower portion of the flashing. Make weather-tight by sealing with caulking. Where possible, cover the sides and top edges of the flash- ing with roofing material.

6.Apply a heavy bead of weatherproof caulking 2 inches above the flashing. Slide the storm collar around the air terminal and down to the caulking. Tighten to ensure that a weather-tight seal between the air terminal and the collar is achieved. Attach the other storm collar centred between the air intake and the air exhaust slots onto the air termi- nal. Tighten securely. Attach the vertical rain cap.

Spacers are at- tached to the 5" in- ner flex liner at pre- determined intervals to maintain a 1-1/4" air gap to the 8" outer liner. These spacers

must not be re- FIGURE 23 moved.

15

7.If more liner needs to be used to reach the fireplace, couple them together as illustrated. The vent system must be supported approximately every 3 feet for both vertical and hori- zontal runs. Use noncombustible strapping to maintain a clearance to combustibles of 1".

FIREPLACE VENT CONNECTION

1.Install the 5 inch diameter aluminium flexible liner to the fireplace. Secure with 3 screws and flat washers. Seal the joint and screw holes using the high temperature seal- ant provided.

2.Install the 8 inch diameter aluminium flexible liner to the fireplace. Attach and seal the joints.

FIGURE 24

USING RIGID VENT COMPONENTS

The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Wolf Steel vent spacers every 3 feet and either side of each elbow to maintain the minimum 1¼" clearance between the outer and inner vent pipes. Use Wolf Steel support ring assem- bly or equivalent noncombustible strapping to maintain the minimum clearance to combustibles for both vertical and horizontal runs.

HORIZONTAL AIR TERMINAL INSTALLATION

FIGURE 25

1.Move the fireplace into po- sition. Measure the vent length required between terminal and fireplace taking into account the additional length needed for the

finished wall surface and any 1¼" overlaps between venting components.

2.Apply high temperature sealant to the outer edge of the 5" inner collar of the fireplace. Attach the first vent component and secure using 3 self tapping screws. Repeat using 8" piping.

3. The heat shield must be

FIGURE 26

installed only when terminat-

 

ing horizontally with no verti-

 

cal rise. Remove the two

 

screws nearest the vent col-

 

lars on the top of the fireplace.

 

Align the vent shield (sup-

 

plied) and secure.

 

4.Holding the air terminal (with the air deflectors to the top), insert into both vent pipes with a twisting motion to ensure that both the terminal sleeves engage into the vent pipes and sealant. Secure the terminal to the exterior wall and make weather tight by sealing with caulking (not supplied).

The air terminal mounting plate may be recessed into the exterior wall or siding by 1½", the depth of the return flange.

EXTENDED HORIZONTAL AIR TERMINAL

INSTALLATION

1.Follow the instructions for "Horizontal Air Terminal In-

stallations", items 1 to 3.

2.Continue adding compo- nents alternating inner and outer venting. Ensure that all 5" venting and elbows have suffi- cient vent spacers attached and each component is securely

fastened to the one prior. Attach the 5" telescopic sleeve to the vent run.

Repeat using a 8" telescopic sleeve. Secure and seal as before. To facilitate completion, attach 5" and 8" couplers to the air terminal.

3.Install the air terminal. See item 3 of the

Horizontal Air Terminal Installation. Extend the 5" telescopic sleeve; connect to the air terminal assembly. Fasten with self tapping screws and seal. Repeat using the 8" tel- escopic sleeve.

Image 15
Contents Direct Vent Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Instructions General InformationCare of GLASS, and Plated Parts Venting Lengths VentingAIR Terminal Installations Special Vent Installations Typical Vent InstallationsHorizontal Termination Vertical Venting Application Flow ChartHorizontal Termination DefinitionsElbow Vent Length Values Formula 1 HT 4.2 VT Formula 2 HT + VT 24.75 feet Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Vertical Installation Horizontal Installation Installation Wall and Ceiling ProtectionVertical AIR Terminal Installation Using Flexible Vent ComponentsFireplace Vent Connection Using Rigid Vent ComponentsVertical Venting Installation GAS InstallationRestricting Vertical Vents Framing Mobile Home InstallationMantle Installation Nailing TAB InstallationPorcelain Reflective Panels GDL42 Louvre Installation Logo PlacementL42 Louvre Installation FinishingCharcoal Embers VermiculiteCharcoal Lumps Optional Blower Installation GD36 Thermostatic Sensor Control Optional FAN InstallationOperation / Maintenance MaintenanceOperating Instructions Adjustments Pilot Burner AdjustmentVenturi Adjustment Replacements Replacement PartsAccessories W415-0381 / C Symptom Problem Test Solution Trouble Shooting GuideDo not Clean Glass When HOT

BGDV42P, BGDV42N specifications

Napoleon Fireplaces has long been synonymous with quality and innovation in the heating and home comfort space. Among their impressive lineup, the BGDV42N and BGDV42P gas fireplaces stand out as exceptional options that combine aesthetic appeal with advanced technology. Designed to meet various needs, these models enhance any living space while providing efficient warmth.

The BGDV42N and BGDV42P feature a large, realistic flame pattern that creates a comforting ambiance. With a viewing area that significantly improves the overall visual impact, users can enjoy a spectacular fire display, making these models perfect for both modern and traditional homes. The glass front design ensures optimal heat retention and efficiency, allowing homeowners to relish in both style and functionality.

Both models operate with unrivaled efficiency, employing innovative technologies such as the advanced variable speed blower. This feature enhances heat distribution throughout the room, ensuring that warmth reaches every corner. Furthermore, their electronic ignition with battery backup ensures dependable performance even during power outages, making them practical choices for any season.

The BGDV42N and BGDV42P come equipped with Napoleon's patented NIGHT LIGHT technology, providing ambient illumination even when the fireplace is turned off. This feature adds versatility, allowing homeowners to create a welcoming atmosphere at any time. The fireplaces also include a choice of decorative media options such as modern crystals or traditional logs, enabling users to customize the appearance to match their personal style.

Safety and ease of use are paramount, and both models offer a range of convenient controls. The remote control allows homeowners to adjust the flame height and temperature with ease, while the built-in safety features, including a glass front that remains cool to the touch, ensure peace of mind during use.

With their combination of beautiful design, advanced technology, and reliable performance, the Napoleon BGDV42N and BGDV42P gas fireplaces represent the pinnacle of modern heating solutions. Whether you seek to upgrade an existing space or create an inviting new focal point, these models provide an ideal solution for comfort and style. Embrace the warmth and elegance that Napoleon Fireplaces offers and transform your living area into a cozy retreat.