Napoleon Fireplaces BGD90NT, BGD90PT manual Installation / Framing Wall and Ceiling Protection

Page 11
FIGURE 16
#8X1/2”
SELF DRILLING SCREWS

11

INSTALLATION / FRAMING

WALL AND CEILING PROTECTION

HORIZONTAL VENT SECTIONS: A minimum clearance of 2” all around the vent pipe on all horizontal runs to combustibles is required except for clearances in fi replace enclosures**. Use fi restop spacer assembly W010-1797 (supplied).

VERTICAL VENT SECTIONS: A minimum of 1” all around the vent pipe on all vertical runs to combustibles is required except for clearances in fi replace enclosures**. Use fi restop spacer W615-0075 (not supplied).

**Horizontal and vertical sections require 5” and 9” clearance from combustibles, respectively. See minimum enclosure clearances sec- tion.

HORIZONTAL INSTALLATION

This application occurs when venting through an exterior wall. Having determined the correct height for the air terminal location, cut and frame a hole in the exterior wall 14 7/8” wide by 14 7/8” high to accommodate the firestop assembly. Dry fit the firestop assembly before proceeding to ensure the brackets on the rear surface fit to the inside surface of the horizontal framing.

NOTE: The firestop assembly must be installed with the vent shield to the top.

CAULKING

FIRESTOP ASSEMBLY

VENT

SHIELD

147/8

14 7/8

The length of the vent shield may be cut shorter for combustible walls that are less than 8 1/2" thick but the vent shield must extend the full depth of the combustible wall.

1.Apply a bead of caulking (not supplied) around the corner edge of the inside surface of the firestop assembly, fit the firestop assembly to the hole and secure using the 4 screws W415-0026 (supplied in your manual baggy).

2.Once the vent pipe is installed in its final position, apply high temperature sealant W573-0007 (not supplied) between the pipe and the firestop.

NOTE: Do not fill the cavity between the pipe and the framing with any type of material.

DETERMINE

THE

CORRECT

HEIGHT

FINISHING

MATERIAL

FIGURE 13

VERTICAL INSTALLATION

This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Authorized dealer. See Accessories to order the specific kit required.

1.Determine the air terminal location, cut and frame

141/2” x 141/2” openings in the ceiling and the roof to provide the minimum 2“ clearance between the fireplace pipe / liner and any combustible material. Try to centre the exhaust pipe location midway between two joist to prevent having to cut them. Use a plumb bob to line up the centre of the openings. Do not fill this space with any type of material.

FIGURE 14

141/2” 141/2

FIRESTOP

UNDERSIDE OF JOIST

A vent pipe shield will prevent any materials such as insulation, from filling up the 1” air space around the pipe. Nail headers between the joist for extra support.

2.Apply a bead of caulking (not supplied) to the framework or to the Wolf Steel vent pipe shield plate or equivalent (in the case of a finished ceiling), and secure over the opening in the ceiling. A firestop must be placed on the bottom of each framed opening in a roof or ceiling that the venting system passes through. Apply a bead of caulking all around and place a firestop spacer over the vent shield to restrict cold air from being drawn into the room or around the fireplace. Ensure that both spacer and shield maintain the required clearance to combustibles. Once the vent pipe is installed in its final position, apply sealant W573-0002 (not supplied) between the pipe and the firestop spacer.

FIGURE 15

CAULKING

VENT PIPE SHIELD

3.In the attic, after the pipe has been installed, slide the vent pipe collar down to cover up the

open end of the shield and tighten. This will prevent any materials, such as insulation, from

2” OVERLAP

filling up the 1” air space around the pipe.

 

 

HI-TEMP

 

SEALANT

W415-0580 / C / 04.07.08

Image 11
Contents Installation Operation Instructions Introduction Table of ContentsNapoleon GAS Fireplace PRESIDENT’S Lifetime Limited Warranty Fireplace Dimensions Installation Overview General Instructions Venting Lengths and AIR Terminal Locations VentingElbow Vent Length Values Horizontal TerminationDefinitions H1 H2 Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Vertical TerminationMinimum AIR Terminal Location Clearances Horizontal Installation Installation / Framing Wall and Ceiling ProtectionElbow Spacers Using Flexible Vent ComponentsFraming Restricting Vertical VentsMIN 23 3 60 3 Minimum Mantel and Enclosure Clearances Hard Wiring ConnectionSchematic Electrical ConnectionLOG Shipping Bracket FinishingDoor Removal Retainer Brick Panel InstallationLOG Placement Andiron PlacementRemote and Valve Access Valve Removal Auto Spark Battery RemovalRemote Receiver Removal Control Module RemovalHand Held Remote Operations Operation / MaintenanceTemperature Display General Transmitter Layout Fireplace OperationFAN Speed Room ThermostatSmart Thermostat Flame HeightNight Light LOW Battery / Manual BypassEvent of a Power Failure Child Proof FunctionLighting Instructions For Your Safety Read Before LightingOperating Instructions What to do if YOU Smell GASVenturi Adjustment AdjustmentsPilot Burner Adjustment Flame CharacteristicsReplacements W415-0580 / C Symptom Problem Test Solution Trouble Shooting GuideCheck that the wire is connected to the spark module Fireplace Service History W415-0580 / C
Related manuals
Manual 32 pages 7.27 Kb

BGD90PT, BGD90NT specifications

The Napoleon Fireplaces BGD90PT and BGD90NT represent the pinnacle of modern fireplace design, combining cutting-edge technology with timeless aesthetics. These models are specifically crafted for those who value both warmth and style in their living spaces.

One of the standout features of the BGD90PT and BGD90NT is their large viewing area, which allows an unobstructed view of the flames, creating a mesmerizing focal point in any room. The expansive glass front enhances the ambiance of the fire, making it feel more immersive and inviting. This sleek design not only provides aesthetic benefits but also improves heat distribution, contributing to the overall efficiency of the fireplace.

The BGD90PT (Propane) and BGD90NT (Natural Gas) models utilize a range of advanced technologies to enhance performance. The patented PHAZER® technology creates a beautiful and realistic flame effect, while the variable speed blower and adjustable heat output allow for customized comfort levels. This precise control ensures that users can maintain the perfect temperature, regardless of outside conditions.

Furthermore, these models are engineered with Napoleon's exclusive TOP-VENT technology, which provides flexible venting options for easy installation. This feature allows homeowners to maximize their living space and choose the venting configuration that best suits their home’s layout.

The BGD90PT and BGD90NT also prioritize safety and efficiency. Both models are equipped with an electronic ignition system that provides reliable start-up, eliminating the hassle of traditional pilot lights. Additionally, the fireplaces include a built-in safety barrier to prevent accidental contact with the glass, making them suitable for homes with children and pets.

With their impressive heat output, the BGD90PT and BGD90NT can efficiently warm larger spaces, contributing to the overall comfort of your home. Their Energy Star rating ensures that they meet the highest standards for energy efficiency, making them an eco-friendly choice.

In terms of design, both models feature a contemporary look that complements various interior styles. From rustic to modern aesthetics, the BGD90PT and BGD90NT can enhance any home décor while providing the warmth and ambiance of a traditional fireplace.

In conclusion, the Napoleon Fireplaces BGD90PT and BGD90NT are an exceptional fusion of design, technology, and efficiency. Their impressive features make them an ideal choice for anyone looking to add a touch of elegance and functionality to their space, all while enjoying the comforting warmth of a beautiful fire.