Napoleon Fireplaces BGD90PT, BGD90NT manual Venting Lengths and AIR Terminal Locations

Page 6

6

VENTING

VENTING LENGTHS AND AIR TERMINAL

LOCATIONS

For safe and proper operation of the fireplace follow the venting instructions exactly.

Deviation from the minimum vertical vent length can create diffi culty in burner start-up and/or carboning.

Provide a means for visually checking the vent connection to the fi replace after the fi replace is installed.

Vent lengths that pass through unheated spaces (attics, garages, crawl spaces) should be insulated with the insulation wrapped in a protective sleeve to minimize condensation.

When using Wolf Steel Ltd.venting components, use only approved Wolf Steel Ltd. fl exible vent components with the following termina- tion kits: WALL TERMINAL KIT GD622, or 1/12 TO 7/12 PITCH ROOF TERMINAL KIT GD610, 8/12 TO 12/12 ROOF TERMINAL KIT GD611, FLAT ROOF TERMINAL KIT GD612. With flexible venting, in conjunction with the various terminations, use either the 5 foot vent kit GD620 or the 10 foot vent kit GD630. These vent kits allow for either horizontal or vertical venting of the fi replace.

The maximum allowable vertical vent length is 40 feet. The maximum number of allowable 8” vent connections is three hori- zontally or vertically (excluding the fi replace and the air terminal connections).

For optimum flame appearance and fi replace performance, keep the vent length and number of elbows to a minimum. The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that it is unobstructed and undamaged.

When venting, the horizontal run must be kept to a maximum of 20 feet. If a 20 foot horizontal run is required, the fireplace must have a minimum vertical rise immediately off the fire- place of 57“. When terminating vertically, the vertical rise is a minimum 3 feet and a maximum 40 feet above the fireplace. FIGURES 3a-b.

FIGURE 3a

24” MAXIMUM

131/2

MINIMUM

71 3/4

MINIMUM

PLUS RISE*

16”

MINIMUM

*

3FEET MINIMUM

FIGURE 3b

40FEET MAXIMUM

*For optimum performance, it is recommended that all hori- zontal runs have a minimum ¼“ rise per foot.

Provide a means for visually checking the vent connection to the fireplace after the fireplace is installed.

Do not allow the inside liner to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight. A 3/4” air gap between the inner and outer liner all around is required for safe operation. Use a firestop when penetrating interior walls, floor or ceil- ing.

For safe and proper operation of the fireplace follow the venting instruction exactly.

If vertical rises greater than 57“ are necessary, the increased rise must be deducted from the horizontal run.

HORIZONTAL VENT SECTIONS: A minimum clearance of 2” all around the vent pipe on all horizontal runs to combustibles is required except for clearances in fi replace enclosures**. Use fi restop spacer assembly W010-1797 (supplied).

VERTICAL VENT SECTIONS: A minimum of 1” all around the vent pipe on all vertical runs to combustibles is required except for clear- ances in fi replace enclosures**. Use fi restop spacer W615-0075 (not supplied).

**Horizontal and vertical sections require 5” and 9” clearance from combustibles, respectively. See minimum enclosure clearances section.

W415-0580 / C / 04.07.08

Image 6
Contents Installation Operation Instructions Table of Contents IntroductionNapoleon GAS Fireplace PRESIDENT’S Lifetime Limited Warranty Fireplace Dimensions Installation Overview General Instructions Venting Venting Lengths and AIR Terminal LocationsHorizontal Termination DefinitionsElbow Vent Length Values H1 H2 Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet ExampleMinimum AIR Terminal Location Clearances Installation / Framing Wall and Ceiling Protection Horizontal InstallationUsing Flexible Vent Components Elbow SpacersRestricting Vertical Vents FramingMIN 23 3 60 3 Electrical Connection Hard Wiring ConnectionSchematic Minimum Mantel and Enclosure ClearancesFinishing Door RemovalLOG Shipping Bracket Brick Panel Installation RetainerAndiron Placement LOG PlacementRemote and Valve Access Control Module Removal Auto Spark Battery RemovalRemote Receiver Removal Valve RemovalGeneral Transmitter Layout Fireplace Operation Operation / MaintenanceTemperature Display Hand Held Remote OperationsFlame Height Room ThermostatSmart Thermostat FAN SpeedChild Proof Function LOW Battery / Manual BypassEvent of a Power Failure Night LightWhat to do if YOU Smell GAS For Your Safety Read Before LightingOperating Instructions Lighting InstructionsFlame Characteristics AdjustmentsPilot Burner Adjustment Venturi AdjustmentReplacements W415-0580 / C Trouble Shooting Guide Symptom Problem Test SolutionCheck that the wire is connected to the spark module Fireplace Service History W415-0580 / C
Related manuals
Manual 32 pages 7.27 Kb

BGD90PT, BGD90NT specifications

The Napoleon Fireplaces BGD90PT and BGD90NT represent the pinnacle of modern fireplace design, combining cutting-edge technology with timeless aesthetics. These models are specifically crafted for those who value both warmth and style in their living spaces.

One of the standout features of the BGD90PT and BGD90NT is their large viewing area, which allows an unobstructed view of the flames, creating a mesmerizing focal point in any room. The expansive glass front enhances the ambiance of the fire, making it feel more immersive and inviting. This sleek design not only provides aesthetic benefits but also improves heat distribution, contributing to the overall efficiency of the fireplace.

The BGD90PT (Propane) and BGD90NT (Natural Gas) models utilize a range of advanced technologies to enhance performance. The patented PHAZER® technology creates a beautiful and realistic flame effect, while the variable speed blower and adjustable heat output allow for customized comfort levels. This precise control ensures that users can maintain the perfect temperature, regardless of outside conditions.

Furthermore, these models are engineered with Napoleon's exclusive TOP-VENT technology, which provides flexible venting options for easy installation. This feature allows homeowners to maximize their living space and choose the venting configuration that best suits their home’s layout.

The BGD90PT and BGD90NT also prioritize safety and efficiency. Both models are equipped with an electronic ignition system that provides reliable start-up, eliminating the hassle of traditional pilot lights. Additionally, the fireplaces include a built-in safety barrier to prevent accidental contact with the glass, making them suitable for homes with children and pets.

With their impressive heat output, the BGD90PT and BGD90NT can efficiently warm larger spaces, contributing to the overall comfort of your home. Their Energy Star rating ensures that they meet the highest standards for energy efficiency, making them an eco-friendly choice.

In terms of design, both models feature a contemporary look that complements various interior styles. From rustic to modern aesthetics, the BGD90PT and BGD90NT can enhance any home décor while providing the warmth and ambiance of a traditional fireplace.

In conclusion, the Napoleon Fireplaces BGD90PT and BGD90NT are an exceptional fusion of design, technology, and efficiency. Their impressive features make them an ideal choice for anyone looking to add a touch of elegance and functionality to their space, all while enjoying the comforting warmth of a beautiful fire.