SYMPTOM

PROBLEM

TEST SOLUTION

 

 

 

Pilot burning; no gas to main burner; Flame height is on ‘HI’; Remote and transmitter ON

Remote receiver

- disconnect switch wires &connect a jumper wire across terminals

 

 

1 & 3; if the main burner lights, check the wires for defects and / or

 

 

replace wires.

Main burner orifi ce is

- remove stoppage in orifi ce.

plugged.

 

 

Faulty thermopile.

- test and replace if required.

Pilot goes out while

Gas piping is undersized.

- turn on all gas appliances and see if pilot fl ame fl utters, diminishes or

standing; Main

 

extinguishes, especially when main burner ignites. Monitor appliance

burner is in ‘OFF’

 

supply working pressure.

position.

 

-

check if supply piping size is to code. Correct all undersized piping.

Pilot will not light.

No spark at pilot burner

-

check if pilot can be lit by a match

PILOT

 

-

check that the wire is connected to the spark module.

BURNER THERMOPILE

-

check batteries.

THERMOCOUPLE

 

-

replace the wire if the wire insulation is broken or frayed.

 

-

replace the electrode if the ceramic insulator is cracked or broken.

 

 

 

 

-

replace spark module.

 

Out of propane gas

-

fi ll the tank.

 

Spark gap is incorrect

-

spark gap should be 0.150” to 0.175” (5/32” to 11/64” approx.) from

 

 

the electrode tip and the pilot burner. To ensure proper electrode loca-

 

 

tion, tighten securing nut (fi nger tight plus 1/4 turn).

 

No gas at the pilot burner

-

check that the manual valve is turned on.

 

 

-

check the pilot orifi ce for blockage.

 

 

-

call the gas distributor.

Main burner goes

Pilot flame is not large enough

-

turn up pilot fl ame.

out; pilot stays on.

or not engulfi ng the thermo-

- replace pilot assembly.

 

pile

 

 

 

Thermopile shorting

- clean thermopile connection to the valve. Reconnect.

 

 

- test and replace thermopile if required.

 

Temperature setting on trans-

-

turn up temperature setting.

 

mitter is satisfi ed

 

 

Main burner goes out; pilot goes out.

Refer to “MAIN BURNER GOES OUT; PILOT STAYS ON”

Vent is blocked

-

check for vent blockage.

Vent is re-circulating

-

check joint seals and installation.

 

 

 

8” fl exible vent has become

-

re-attach to fi replace.

disconnected from fi replace.

 

 

Flames are consis- tently too large or too small. Carbon- ing occurs.

Unit is over-fi red or under- fi red.

BA

- check pressure readings:

Inlet pressure can be checked by turning screw (A) counter-clock-wise 2 or 3 turns and then placing pressure gauge tubing over the test point. Gauge should read 7” (minimum 4.5”) water column for natural gas or 13” (11” minimum) water column for propane. Check that main burner is operating on “HI”.

Outlet pressure can be checked the same as above using screw (B). Gauge should read 3.5” water column for natural gas or 10” water column for propane. Check that main burner is operating on “HI”.

AFTER TAKING PRESSURE READINGS, BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL. DO NOT OVER- TORQUE.

Leak test with a soap and water solution.

W415-0580 / C / 04.07.08

Image 30
Contents Installation Operation Instructions Table of Contents IntroductionNapoleon GAS Fireplace PRESIDENT’S Lifetime Limited Warranty Fireplace Dimensions Installation Overview General Instructions Venting Venting Lengths and AIR Terminal LocationsHorizontal Termination DefinitionsElbow Vent Length Values H1 H2 Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet ExampleMinimum AIR Terminal Location Clearances Installation / Framing Wall and Ceiling Protection Horizontal InstallationUsing Flexible Vent Components Elbow SpacersRestricting Vertical Vents FramingMIN 23 3 60 3 Electrical Connection Hard Wiring ConnectionSchematic Minimum Mantel and Enclosure ClearancesFinishing Door RemovalLOG Shipping Bracket Brick Panel Installation RetainerAndiron Placement LOG PlacementRemote and Valve Access Control Module Removal Auto Spark Battery RemovalRemote Receiver Removal Valve RemovalGeneral Transmitter Layout Fireplace Operation Operation / MaintenanceTemperature Display Hand Held Remote OperationsFlame Height Room ThermostatSmart Thermostat FAN SpeedChild Proof Function LOW Battery / Manual BypassEvent of a Power Failure Night LightWhat to do if YOU Smell GAS For Your Safety Read Before LightingOperating Instructions Lighting InstructionsFlame Characteristics AdjustmentsPilot Burner Adjustment Venturi AdjustmentReplacements W415-0580 / C Trouble Shooting Guide Symptom Problem Test SolutionCheck that the wire is connected to the spark module Fireplace Service History W415-0580 / C
Related manuals
Manual 32 pages 7.27 Kb

BGD90PT, BGD90NT specifications

The Napoleon Fireplaces BGD90PT and BGD90NT represent the pinnacle of modern fireplace design, combining cutting-edge technology with timeless aesthetics. These models are specifically crafted for those who value both warmth and style in their living spaces.

One of the standout features of the BGD90PT and BGD90NT is their large viewing area, which allows an unobstructed view of the flames, creating a mesmerizing focal point in any room. The expansive glass front enhances the ambiance of the fire, making it feel more immersive and inviting. This sleek design not only provides aesthetic benefits but also improves heat distribution, contributing to the overall efficiency of the fireplace.

The BGD90PT (Propane) and BGD90NT (Natural Gas) models utilize a range of advanced technologies to enhance performance. The patented PHAZER® technology creates a beautiful and realistic flame effect, while the variable speed blower and adjustable heat output allow for customized comfort levels. This precise control ensures that users can maintain the perfect temperature, regardless of outside conditions.

Furthermore, these models are engineered with Napoleon's exclusive TOP-VENT technology, which provides flexible venting options for easy installation. This feature allows homeowners to maximize their living space and choose the venting configuration that best suits their home’s layout.

The BGD90PT and BGD90NT also prioritize safety and efficiency. Both models are equipped with an electronic ignition system that provides reliable start-up, eliminating the hassle of traditional pilot lights. Additionally, the fireplaces include a built-in safety barrier to prevent accidental contact with the glass, making them suitable for homes with children and pets.

With their impressive heat output, the BGD90PT and BGD90NT can efficiently warm larger spaces, contributing to the overall comfort of your home. Their Energy Star rating ensures that they meet the highest standards for energy efficiency, making them an eco-friendly choice.

In terms of design, both models feature a contemporary look that complements various interior styles. From rustic to modern aesthetics, the BGD90PT and BGD90NT can enhance any home décor while providing the warmth and ambiance of a traditional fireplace.

In conclusion, the Napoleon Fireplaces BGD90PT and BGD90NT are an exceptional fusion of design, technology, and efficiency. Their impressive features make them an ideal choice for anyone looking to add a touch of elegance and functionality to their space, all while enjoying the comforting warmth of a beautiful fire.