Napoleon Fireplaces BGD90PT, BGD90NT manual Restricting Vertical Vents, Mobile Home Installation

Page 12
BLACK
FIGURE 24
ADAPTER
FITTING
SHUT OFF VALVE
FLEXIBLE CONNECTOR
FIGURE 23
Proceed once the vent installation is complete.
Note : All gas connections must be contained within
the fireplace when complete.
1. The fi replace is designed to accept a ½” gas supply line. The fireplace is equipped with a ½” manual shut-off valve, and an 18” listed fl exible
gas connector.
12
FIREPLACE VENT CONNECTION
1. Install the 8” diameter fl exible aluminium liner to the fi replace. Secure with 3 screws. Seal the joint and screw holes using the high temperature sealant (W573-0007 not provided).
2. Install the 10” diameter fl exible aluminium liner to the fi replace. Attach and seal the joints.
GAS INSTALLATION

This appliance is certifi ed to be installed in an aftermarket permanently located manufactured (mobile) home, where not prohibited by local codes.

RESTRICTING VERTICAL VENTS

 

2. The access to the gas inlet

 

is located on the right side of

 

the outer shell.

 

3. To ease the connection,

 

the shut off can be fl exed out

 

through the side of the fireplace

6"

where the connection can be

made.

 

4. When fl exing any gas line, support the gas valve so that

the lines are not bent. (see Access Pg. 20).

5.Check for gas leaks by brushing on a soap and water solu- tion. Do not use open flame.

MOBILE HOME INSTALLATION

This appliance is certifi ed to be installed as an OEM (Origi- nal Equipment Manufacturer) installation in a manufactured home or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufac- tured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada. This ap- pliance is only for use with the type(s) of gas indicated on the rating plate. A conversion kit is supplied with the mobile home appliance.

This Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit.

The fi replace is equipped with two 1/4” diameter holes located in the fron left and right corners of the base. For mobile home installations, the fi replace must be fastened in place. Use #10 hex head screws, inserted through the holes in the base to secure.

Always turn off the pilot and the fuel supply at the source, prior to moving the mobile home.

After moving the mobile home and prior to lighting the fireplace, ensure that the logs are positioned correctly.

FLUE COLLAR

RESTRICTOR

PLATE

FIGURE 25

Vertical terminations may display a very active fl ame. If this appearance is not desirable, the vent exit must be restricted using restrictor plate, W500-0321. This reduces the velocity of the exhaust gases, slowing down the fl ame pattern and creating a more traditional appearance.

The plate has a series of holes to allow for adjustment. Remove the two screws on either side of the exhaust collar inside the fi rebox. Install the plate in the desired set of holes, then replace the screws.

It is recommended to secure in the third set of holes which causes the greatest amount of restriction for vent lengths between 15 and 30 feet.

W415-0614 / A / 07.24.07

Image 12
Contents Installation Table of Contents Napoleon GAS Fireplace PRESIDENT’S Lifetime Limited Warranty General Instructions General InformationTo stand-offs top, rear and sides Vent pipe InchesVenting Care of GLASS, and Plated PartsVenting Lengths & AIR Terminal Locations TOP Exit / Horizontal Termination DefinitionsElbow Vent Length Values = 4 ft = 1.5 ft= V1 + V2 = 4 + 1.5 = 5.5 ft = 2 ftTOP Exit Vertical Termination TOP Vertical TerminationAIR Terminal Installations Installation Wall and Ceiling Protection Vertical InstallationHorizontal Installation See figure15Using Flexible Vent Components Horizontal AIR Terminal InstallationVertical AIR Terminal Installation Use only approved aluminum flexible liner kits markedMobile Home Installation Restricting Vertical VentsFraming Clearance to Combustibles22 3/8 to top of fireplace opening Hard Wiring Connection Access panel must be re-installed before operating the unitIt is necessary to hard wire this fireplace Electrical ConnectionGLASS/DOOR Replacement FinishingDoor Removal LOG Shipping BracketBrick Panel Installation Install Panels in the Following OrderAndiron Placement LOG PlacementNight Light Replacement Charcoal EmbersVermiculite Glowing EmbersRemote and Valve Access Operation / Maintenance Time OUTFireplace Operation Hand Held Remote OperationsFAN Speed Setting Address Setting Procedure DIP Switch Number 0 = on / 1 = OFF For Your Safety Read Before Lighting Operating InstructionsLighting Instructions What to do if YOU Smell GASAdjustments MaintenanceFuel Conversion Pilot Burner Adjustment Flame CharacteristicsVenturi Adjustment Check Pressure Readings FigReplacements 000 Trouble Shooting Guide Symptom Problem Test SolutionCheck that the wire is connected to the spark module Fireplace Service History W415-0614 / a
Related manuals
Manual 32 pages 38.75 Kb

BGD90PT, BGD90NT specifications

The Napoleon Fireplaces BGD90PT and BGD90NT represent the pinnacle of modern fireplace design, combining cutting-edge technology with timeless aesthetics. These models are specifically crafted for those who value both warmth and style in their living spaces.

One of the standout features of the BGD90PT and BGD90NT is their large viewing area, which allows an unobstructed view of the flames, creating a mesmerizing focal point in any room. The expansive glass front enhances the ambiance of the fire, making it feel more immersive and inviting. This sleek design not only provides aesthetic benefits but also improves heat distribution, contributing to the overall efficiency of the fireplace.

The BGD90PT (Propane) and BGD90NT (Natural Gas) models utilize a range of advanced technologies to enhance performance. The patented PHAZER® technology creates a beautiful and realistic flame effect, while the variable speed blower and adjustable heat output allow for customized comfort levels. This precise control ensures that users can maintain the perfect temperature, regardless of outside conditions.

Furthermore, these models are engineered with Napoleon's exclusive TOP-VENT technology, which provides flexible venting options for easy installation. This feature allows homeowners to maximize their living space and choose the venting configuration that best suits their home’s layout.

The BGD90PT and BGD90NT also prioritize safety and efficiency. Both models are equipped with an electronic ignition system that provides reliable start-up, eliminating the hassle of traditional pilot lights. Additionally, the fireplaces include a built-in safety barrier to prevent accidental contact with the glass, making them suitable for homes with children and pets.

With their impressive heat output, the BGD90PT and BGD90NT can efficiently warm larger spaces, contributing to the overall comfort of your home. Their Energy Star rating ensures that they meet the highest standards for energy efficiency, making them an eco-friendly choice.

In terms of design, both models feature a contemporary look that complements various interior styles. From rustic to modern aesthetics, the BGD90PT and BGD90NT can enhance any home décor while providing the warmth and ambiance of a traditional fireplace.

In conclusion, the Napoleon Fireplaces BGD90PT and BGD90NT are an exceptional fusion of design, technology, and efficiency. Their impressive features make them an ideal choice for anyone looking to add a touch of elegance and functionality to their space, all while enjoying the comforting warmth of a beautiful fire.