Napoleon Fireplaces BGD90NT, BGD90PT manual Venting, Care of GLASS, and Plated Parts

Page 5

CARE OF GLASS, AND PLATED PARTS

Do not use abrasive cleaners to clean glass. Buff lightly with a clean dry cloth. The glass is 3/16” tempered glass avail- able from your NAPOLEON® / Wolf Steel Ltd. dealer. DO NOT SUBSTITUTE MATERIALS. Clean the glass after the

rst 10 hours of operation with a recommended gas fi replace glass cleaner. Thereafter clean as required. DO NOT CLEAN GLASS WHEN HOT! If the glass is not kept clean permanent discolouration and / or blemishes may result.

5

We Suggest that our gas hearth products be installed and serviced by profession- als who are certified in the U.S. by the National Fire- place Institute (NFI) as NFI Gas Specialists.

VENTING

Note: If for any reason the vent air intake system is disas- sembled; reinstall per the instructions provided for the initial installations.

VENTING LENGTHS & AIR TERMINAL

LOCATIONS

For safe and proper operation of the fireplace follow the venting instuction exactly.

Deviation from the minimum vertical vent length can create diffi culty in burner start-up and/or carboning.

Provide a means for visually checking the vent connection to the fi replace after the fi replace is installed.

Vent lengths that pass through unheated spaces (attics, ga- rages, crawl spaces) should be insulated with the insulation wrapped in a protective sleeve to minimize condensation.

When using NAPOLEON® venting components, use only approved Wolf Steel Ltd. fl exible vent components with the following termination kits: WALL TERMINAL KIT GD622, or 1/12 TO 7/12 PITCH ROOF TERMINAL KIT GD610, 8/12 TO 12/12 ROOF TERMINAL KIT GD611, FLAT ROOF TERMINAL KIT GD612. With fl exible venting, in conjunction with the various terminations, use either the 5 foot vent kit GD620 or the 10 foot vent kit GD630. These vent kits allow for either horizontal or vertical venting of the fi replace.

The maximum allowable vertical vent length is 40 feet. The maximum number of allowable 8” vent connections is three horizontally or vertically (excluding the fi replace and the air terminal connections).

For optimum fl ame appearance and fi replace performance, keep the vent length and number of elbows to a minimum. The air terminal must remain unobstructed at all times. Ex- amine the air terminal at least once a year to verify that it is unobstructed and undamaged.

When venting, the horizontal run must be kept to a minimum of 16 inches or a maximum of 20 feet. If a 20 foot horizontal run is required, the fireplace must have a minimum vertical rise immediately off the fireplace of 57 inches. FIGURES 2a-c. When terminating vertically, the vertical rise is a minimum 34 inches and a maximum 40 feet above the fireplace. FIGURE 3.

FIGURES 2A-B

16"

24"

12"

FIGURE 3

For optimum performance, it is recommended that all horizontal runs have a minimum ¼ inch rise per foot. Provide a means for visually checking the vent connec- tion to the fireplace after the fireplace is installed.

Do not allow the inside liner to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight. A 3/4” air gap between the inner and outer liner all around is required for safe operation.

Use a firestop when penetrating interior walls, floor or ceiling.

For safe and proper operation of the fireplace follow the venting instruction exactly.

If vertical rises greater than 57 inches are necessary, the increased rise must be deducted from the horizontal run.

W415-0614 / A / 07.24.07

Image 5
Contents Installation Table of Contents Napoleon GAS Fireplace PRESIDENT’S Lifetime Limited Warranty General Information General InstructionsTo stand-offs top, rear and sides Vent pipe InchesVenting Lengths & AIR Terminal Locations VentingCare of GLASS, and Plated Parts Elbow Vent Length Values TOP Exit / Horizontal TerminationDefinitions = 1.5 ft = 4 ft= V1 + V2 = 4 + 1.5 = 5.5 ft = 2 ftTOP Vertical Termination TOP Exit Vertical TerminationAIR Terminal Installations Vertical Installation Installation Wall and Ceiling ProtectionHorizontal Installation See figure15Horizontal AIR Terminal Installation Using Flexible Vent ComponentsVertical AIR Terminal Installation Use only approved aluminum flexible liner kits markedRestricting Vertical Vents Mobile Home Installation22 3/8 to top of fireplace opening FramingClearance to Combustibles Access panel must be re-installed before operating the unit Hard Wiring ConnectionIt is necessary to hard wire this fireplace Electrical ConnectionFinishing GLASS/DOOR ReplacementDoor Removal LOG Shipping BracketInstall Panels in the Following Order Brick Panel InstallationLOG Placement Andiron PlacementCharcoal Embers Night Light ReplacementVermiculite Glowing EmbersRemote and Valve Access Time OUT Operation / MaintenanceFireplace Operation Hand Held Remote OperationsFAN Speed Setting Address Setting Procedure DIP Switch Number 0 = on / 1 = OFF Operating Instructions For Your Safety Read Before LightingLighting Instructions What to do if YOU Smell GASFuel Conversion AdjustmentsMaintenance Flame Characteristics Pilot Burner AdjustmentVenturi Adjustment Check Pressure Readings FigReplacements 000 Symptom Problem Test Solution Trouble Shooting GuideCheck that the wire is connected to the spark module Fireplace Service History W415-0614 / a
Related manuals
Manual 32 pages 38.75 Kb

BGD90PT, BGD90NT specifications

The Napoleon Fireplaces BGD90PT and BGD90NT represent the pinnacle of modern fireplace design, combining cutting-edge technology with timeless aesthetics. These models are specifically crafted for those who value both warmth and style in their living spaces.

One of the standout features of the BGD90PT and BGD90NT is their large viewing area, which allows an unobstructed view of the flames, creating a mesmerizing focal point in any room. The expansive glass front enhances the ambiance of the fire, making it feel more immersive and inviting. This sleek design not only provides aesthetic benefits but also improves heat distribution, contributing to the overall efficiency of the fireplace.

The BGD90PT (Propane) and BGD90NT (Natural Gas) models utilize a range of advanced technologies to enhance performance. The patented PHAZER® technology creates a beautiful and realistic flame effect, while the variable speed blower and adjustable heat output allow for customized comfort levels. This precise control ensures that users can maintain the perfect temperature, regardless of outside conditions.

Furthermore, these models are engineered with Napoleon's exclusive TOP-VENT technology, which provides flexible venting options for easy installation. This feature allows homeowners to maximize their living space and choose the venting configuration that best suits their home’s layout.

The BGD90PT and BGD90NT also prioritize safety and efficiency. Both models are equipped with an electronic ignition system that provides reliable start-up, eliminating the hassle of traditional pilot lights. Additionally, the fireplaces include a built-in safety barrier to prevent accidental contact with the glass, making them suitable for homes with children and pets.

With their impressive heat output, the BGD90PT and BGD90NT can efficiently warm larger spaces, contributing to the overall comfort of your home. Their Energy Star rating ensures that they meet the highest standards for energy efficiency, making them an eco-friendly choice.

In terms of design, both models feature a contemporary look that complements various interior styles. From rustic to modern aesthetics, the BGD90PT and BGD90NT can enhance any home décor while providing the warmth and ambiance of a traditional fireplace.

In conclusion, the Napoleon Fireplaces BGD90PT and BGD90NT are an exceptional fusion of design, technology, and efficiency. Their impressive features make them an ideal choice for anyone looking to add a touch of elegance and functionality to their space, all while enjoying the comforting warmth of a beautiful fire.