Trane TSC060-120 manual Standardized Components, Easy Access Low Voltage Terminal Board

Page 5

Features and Benefits

Standardized Components

Components are placed in the same location on all Precedentunits. Familiarize yourself with one Precedent and you are familiar with every Precedent.

Easy Access Low Voltage Terminal Board

Precedent’s Low Voltage Terminal Board is external to the electrical control cabinet. It is extremely easy to locate and attach the thermostat wire. This is another cost and time saving installation feature.

Low Voltage Connections The wiring of the low voltage connections to the unit and the zone sensors is as simple as 1-1,2-2, and 3-3. This simplified system makes it easy for the installer to wire

Single-Side Service

Single-side service is standard on all Precedent units.

Flexible Applications

Only two roof curbs for the 5-10 ton Precedent line. . .simplifies curb selection.

ReliaTel microprocessor controls to meet either the simple or the more complex application.

Airflow is outstanding. The Precedent can replace an older machine with old ductwork and, in many cases, improve comfort through better air distribution.

Belt drive — standard or oversized supply fan motors meet a wide airflow range.

Precedent offers ultimate flexibility. Options and components are not pre- packaged at the factory. Units are built to order in our standard “shortest in the industry” ship cycle time.

RT-PRC016-EN

5

Image 5
Contents Packaged Cooling with Electric Heat Rooftop Units American Standard Inc. All rights reserved IntroductionContents Features and Benefits Flexible Applications Easy Access Low Voltage Terminal BoardStandardized Components ReliaTel Micro Micro ControlsPhase Monitor Hinged Access DoorsEconomizer Comm-3/4Trane Communication InterfaceVariTrac Quality And Reliability TestingWe test designs at our factory not on our customers Condensate Trap Barometric ReliefClearance Requirements Unit PitchCooling Capacity Step Accessory SelectionHeating Capacity Step Air Delivery SelectionSelection Procedure IP Units 060 11 12,13 Model Number DescriptionTable GD 1 General Data General DataTable PD-1a Gross Cooling Capacities MBH TSC060AD IP Performance DataTable PD-1 Gross Cooling Capacities kW -TSC060AD SI Table PD-2a Gross Cooling Capacities MBH -TSC072AD IP Table PD-2 Gross Cooling Capacities kW -TSC072AD SITable PD-3a Gross Cooling Capacities MBH -TSC090AD IP Table PD-3 Gross Cooling Capacities kW -TSC090AD SITable PD-4a Gross Cooling Capacities MBH -TSC102AD IP Table PD-4 Gross Cooling Capacities kW -TSC102AD SITable PD-5a Gross Cooling Capacities MBH -TSC120AD IP Table PD-5 Gross Cooling Capacities kW -TSC120AD SIHi Static Drive ← 1.12 Nom kW Standard Motor2 HP Standard Motor & Drive ← 1-1/2 HP Standard Motor2 HP Standard Motor Nom kW Standard Motor & Drive← 1.12 Nom kW Standard Motor & Hi Static Drive Nom kW Over-Sized Motor Hi Static Drive Nom kW Std Motor2 HP Standard Motor Hi Static Drive 2 HP Standard Mtr DriveNom kW Over-Sized Motor & Hi Static Drive Nom kW Standard Motor & Hi Static Drive2 HP Standard Motor & Low Static Drive 2 HP Std Motor & Hi Static DriveHP Standard Mtr HP Standard Motor Drive Hi Static Drive Motor & Hi Static Drive Nom kW Standard Motor & Drive Nom kW OSHP Std Motor & Low Static Drive HP Std Motor & Hi Static Drive HP Over-Sized MotorHP Standard Mtr & Drive HP Std Motor & Hi Static Drive Nom kW Over-Sized Motor & High Static DriveHP Standard Motor & Low Static Drive Nom kW Standard Motor & High Static Drive Nom kW Std Mtr Nom kW Over-Sized High Static DriveHP Std Mtr & Low Static Drive HP Over-Sized Mtr & DriveNom kW Standard Motor & Low Static Drive HP Standard Motor & High Static Drive 275 300 325 350 375 400 425 450 475 500Table PD-19 Oversized Motor & Drive Sheave/Fan Speed RPM Table PD-20 Sound Power Level dB ref -12WattsTable PD-16 Standard Motor & Sheave/Fan Speed RPM Unit Airflow Standard Pleated Filters OA/RA Dampers2 Economizer100% OA 100% RA Model No M3/h Downflow Horizontal 13-27Table PD-23A Auxiliary Electric Heat Capacity IP Table PD-23 Auxiliary Electric Heat Capacity SI10.9 13.0 07.5 09.011.3 13.5 14.4 17.2Automatic Changeover One Heat Zone ControlsZone Sensors Electrical Data Table ED-1 Unit WiringJobsite Connections Zone Sensors Typical Number Of WiresTSC060 DimensionalDataTSC060 DataTSC060 TSC072-090 TSC102-120 DataTSC072-120 ALL Flanges 1 1/4 31 MM TSC060 Swing Diameter for Hinged Doors Option Dimensional TSC060TSC060 Economizer , Manual or Motorized Fresh Air Damper Dimensional TSC072-120 Table W-2a Accessory Net Weights1 2 lbs WeightsTable W-2 Accessory Net Weights1 2 kg Mechanical Specifications Electric Heaters Clogged Filter/Fan Failure SwitchRoof Curb Remote PotentiometerComm-5 LonTalk Communication Interface Differential Pressure SwitchesZone Sensor ThermostatsFile Number PL-UN-000-RT-PRC016-EN-02-04 Literature Order NumberSupersedes PL-UN-000-RT-PRC016-EN-12-03 Stocking Location 03-03Webb/Mason 02-04 Electronic Only

TSC060-120 specifications

The Trane TSC060-120 is a prominent member of Trane's commercial HVAC (Heating, Ventilation, and Air Conditioning) systems, designed to meet the demands of various applications, from small offices to larger commercial venues. This model is part of Trane’s variable refrigerant flow (VRF) systems, which are known for their energy efficiency and flexibility.

One of the standout features of the TSC060-120 is its capacity range, which allows for cooling and heating capacities between 60,000 to 120,000 BTUs. This makes it suitable for diverse environments, adapting well to fluctuating load requirements. Additionally, the unit is designed with a modular approach, meaning that multiple units can be connected to meet larger capacity needs without sacrificing efficiency.

The Trane TSC060-120 incorporates advanced inverter technology, which helps optimize energy consumption by adjusting the compressor speed based on the real-time thermal load of the building. This results in a significant reduction in energy costs and improved comfort levels for occupants. The unit also features a high-efficiency multi-stage filtration system that not only ensures clean air circulation but also contributes to the overall indoor air quality.

The system utilizes a compact and versatile design, allowing for flexible installation options. Its lightweight structure and smaller footprint make it easier to install in tight spaces while still accommodating a powerful performance. The TSC060-120 is designed for quiet operation, which is crucial for noise-sensitive environments, delivering comfort without disruptive sound levels.

In terms of control and monitoring, the TSC060-120 is compatible with Trane's advanced building management systems. This integration allows facility managers to monitor energy usage, schedule maintenance, and control temperatures remotely, enhancing overall operational efficiency.

Moreover, the unit is built with sustainability in mind, using eco-friendly refrigerants that comply with the latest environmental regulations. This commitment to sustainability not only minimizes the ecological footprint but also positions the Trane TSC060-120 as a forward-thinking choice for businesses looking to enhance their energy strategy.

In summary, the Trane TSC060-120 stands out for its efficiency, flexibility, and advanced technology, making it a solid choice for commercial HVAC applications. With its combination of high performance, advanced control features, and commitment to sustainability, it provides an effective solution for modern climate control needs.