Trane TSC060-120 manual Nom kW Standard Motor & Low Static Drive

Page 27

Performance

Data

Table PD-14 — Belt Drive Evaporator Fan Performance -TSC120AD - Downflow Configuration (SI)

 

 

 

 

 

 

 

 

 

 

 

External Static Pressure (Pascals)

 

 

 

 

 

 

 

 

 

25

 

 

50

 

 

75

 

100

125

150

175

200

225

250

m3/h

RPM

kW

RPM

kW

 

RPM

kW

RPM

kW

 

 

RPM

kW

 

RPM

kW

RPM

kW

RPM

kW

RPM

kW

RPM

kW

 

 

 

2.24 Nom kW Standard Motor & Low Static Drive

 

 

 

 

2.24 Nom kW Standard Motor & Drive

 

 

5440

-

-

-

-

-

-

 

-

-

718

0.72

 

754

0.82

789

0.93

822

1.03

856

1.14

887

1.25

6120

-

-

-

-

-

-

 

731

0.81

764

0.90

 

797

0.99

829

1.10

860

1.22

892

1.34

922

1.46

6800

-

-

715

0.81

747

0.90

 

782

1.01

814

1.11

844

1.21

874

1.32

903

1.44

932

1.56

960

1.69

7480

741

0.95

773

1.04

 

803

1.14

 

834

1.24

864

1.36

894

1.48

922

1.59

948

1.70

975

1.82

1001

1.95

8160

803

1.21

833

1.31

861

1.42

 

887

1.52

916

1.64

945

1.77

972

1.90

997

2.02

1022

2.14

1046

2.27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External Static Pressure (Pascals)

 

 

 

 

 

 

 

 

 

275

 

300

325

 

350

375

400

425

450

475

500

m3/h

RPM

kW

RPM

kW

 

RPM

kW

RPM

kW

 

 

RPM

kW

 

RPM

kW

RPM

kW

RPM

kW

RPM

kW

RPM

kW

 

 

2.24 Nom kW Standard Motor & Drive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5440

917

1.36

945

1.47

973

1.60

 

999

1.72

1024

1.84

1048

1.97

1072

2.10

1095

2.23

1117

2.37

1140

3.36

6120

951

1.57

979

1.69

1007

1.82

 

1033

1.94

 

1059

2.07

1082

2.20

1107

2.34

1130

2.49

1152

2.63

1173

3.71

6800

988

1.82

1015

1.95

1042

2.08

 

1068

2.21

 

 

1093

2.35

1117

2.48

1142

2.63

1164

2.76

1187

2.91

1209

4.11

7480

1028

2.09

1053

2.23

1078

2.38

 

1103

2.52

1128

2.66

1152

2.81

1176

2.95

1198

3.10

1221

3.25

-

-

8160

1071

2.41

1095

2.55

1119

2.70

 

1142

2.86

1166

3.02

1189

3.17

1212

3.33

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

2.24 Nom kW Standard Motor & High Static Drive

 

 

 

 

 

 

Notes:

Data Includes Pressure Drop Due To Wet Coils And Filters.

Factory Supplied Motors, In Commercial Equipment, Are Definite Purpose Motors, Specifically Designed And Tested To

Operate Reliably And Continuously At All Cataloged Conditions. Using The Full Horsepower Range Of Our Fan Motors

2.24 kW - Fan Motor Heat (kW) = 1.138 x Fan kW + 0.139

As Shown In Our Tabular Data Will Not Result In Nuisance Tripping Or Premature Motor Failure. Our Product’s Warranty

 

 

Will Not Be Affected.

Table PD-14a — Belt Drive Evaporator Fan Performance -TSC120AD - Downflow Configuration (IP)

 

 

 

 

 

 

 

 

 

 

External Static Pressure (Inches of Water)

 

 

 

 

 

 

 

 

 

 

.10

 

.20

 

 

 

.30

.40

.50

 

 

 

.60

 

 

.70

.80

 

.90

 

1.00

CFM

RPM

BHP

RPM

BHP

 

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

 

 

 

 

3 HP Standard Motor & Low Static Drive

 

 

 

 

 

 

 

3 HP Standard Motor & Drive

 

 

3200

 

-

-

-

-

-

-

-

-

718

0.97

 

754

1.10

 

789

1.25

822

1.38

856

1.53

887

1.67

3600

 

-

-

-

-

-

-

731

1.08

764

1.20

 

797

1.33

 

829

1.48

860

1.63

892

1.79

922

1.95

4000

 

-

-

715

1.09

747

1.21

782

1.35

814

1.49

 

844

1.63

 

874

1.77

903

1.93

932

2.09

960

2.27

4400

 

741

1.27

773

1.40

803

1.53

834

1.67

864

1.82

 

894

1.98

 

922

2.13

948

2.28

975

2.44

1001

2.62

4800

 

803

1.62

833

1.76

861

1.90

887

2.04

916

2.20

 

945

2.38

 

972

2.55

997

2.71

1022

2.87

1046

3.04

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External Static Pressure (Inches of Water)

 

 

 

 

 

 

 

 

 

 

1.10

1.20

1.30

1.40

1.50

 

1.60

 

1.70

1.80

1.90

2.00

CFM

RPM

BHP

RPM

BHP

 

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

 

 

 

 

 

3 HP Standard Motor & Drive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3200

 

917

1.82

945

1.97

973

2.14

999

2.30

1024

2.47

 

1048

2.65

 

1072

2.82

1095

3.00

1117

3.17

1140

3.36

3600

 

951

2.11

979

2.27

1007

2.43

1033

2.60

1059

2.78

 

1082

2.95

 

1107

3.14

1130

3.33

1152

3.52

1173

3.71

4000

 

988

2.44

1015

2.62

1042

2.79

1068

2.97

1093

3.15

 

1117

3.33

 

1142

3.52

1164

3.70

1187

3.91

1209

4.11

4400

 

1028

2.81

1053

3.00

 

1078

3.19

1103

3.38

1128

3.57

 

1152

3.77

 

1176

3.96

1198

4.15

1221

4.36

-

-

4800

 

1071

3.23

1095

3.42

 

1119

3.62

1142

3.83

1166

4.04

 

1189

4.25

 

1212

4.46

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

3 HP Standard Motor & High Static Drive

 

 

 

 

 

 

 

Notes:

Data Includes Pressure Drop Due To Wet Coils And Filters.

Factory Supplied Motors, In Commercial Equipment, Are Definite Purpose Motors, Specifically Designed And Tested To

Operate Reliably And Continuously At All Cataloged Conditions. Using The Full Horsepower Range Of Our Fan Motors

3 HP - Fan Motor Heat (MBH) = 2.900 x Fan BHP + 0.475

As Shown In Our Tabular Data Will Not Result In Nuisance Tripping Or Premature Motor Failure. Our Product’s Warranty

 

 

Will Not Be Affected.

RT-PRC016-EN

27

Image 27
Contents Packaged Cooling with Electric Heat Rooftop Units American Standard Inc. All rights reserved IntroductionContents Features and Benefits Easy Access Low Voltage Terminal Board Standardized ComponentsFlexible Applications ReliaTel Micro Micro ControlsComm-3/4Trane Communication Interface Hinged Access DoorsPhase Monitor EconomizerQuality And Reliability Testing We test designs at our factory not on our customersVariTrac Unit Pitch Barometric ReliefCondensate Trap Clearance RequirementsAir Delivery Selection Accessory SelectionCooling Capacity Step Heating Capacity StepSelection Procedure IP Units 060 11 12,13 Model Number DescriptionTable GD 1 General Data General DataPerformance Data Table PD-1 Gross Cooling Capacities kW -TSC060AD SITable PD-1a Gross Cooling Capacities MBH TSC060AD IP Table PD-2a Gross Cooling Capacities MBH -TSC072AD IP Table PD-2 Gross Cooling Capacities kW -TSC072AD SITable PD-3a Gross Cooling Capacities MBH -TSC090AD IP Table PD-3 Gross Cooling Capacities kW -TSC090AD SITable PD-4a Gross Cooling Capacities MBH -TSC102AD IP Table PD-4 Gross Cooling Capacities kW -TSC102AD SITable PD-5a Gross Cooling Capacities MBH -TSC120AD IP Table PD-5 Gross Cooling Capacities kW -TSC120AD SI← 1-1/2 HP Standard Motor ← 1.12 Nom kW Standard MotorHi Static Drive 2 HP Standard Motor & DriveNom kW Standard Motor & Drive ← 1.12 Nom kW Standard Motor & Hi Static Drive2 HP Standard Motor 2 HP Standard Mtr Drive Nom kW Std MotorNom kW Over-Sized Motor Hi Static Drive 2 HP Standard Motor Hi Static Drive2 HP Std Motor & Hi Static Drive Nom kW Standard Motor & Hi Static DriveNom kW Over-Sized Motor & Hi Static Drive 2 HP Standard Motor & Low Static DriveHP Standard Mtr HP Standard Motor Drive Hi Static Drive HP Std Motor & Hi Static Drive HP Over-Sized Motor Nom kW Standard Motor & Drive Nom kW OSMotor & Hi Static Drive HP Std Motor & Low Static DriveNom kW Over-Sized Motor & High Static Drive HP Standard Motor & Low Static DriveHP Standard Mtr & Drive HP Std Motor & Hi Static Drive HP Over-Sized Mtr & Drive Nom kW Std Mtr Nom kW Over-Sized High Static DriveNom kW Standard Motor & High Static Drive HP Std Mtr & Low Static DriveNom kW Standard Motor & Low Static Drive HP Standard Motor & High Static Drive 275 300 325 350 375 400 425 450 475 500Table PD-20 Sound Power Level dB ref -12Watts Table PD-16 Standard Motor & Sheave/Fan Speed RPMTable PD-19 Oversized Motor & Drive Sheave/Fan Speed RPM Downflow Horizontal 13-27 EconomizerUnit Airflow Standard Pleated Filters OA/RA Dampers2 100% OA 100% RA Model No M3/hTable PD-23A Auxiliary Electric Heat Capacity IP Table PD-23 Auxiliary Electric Heat Capacity SI14.4 17.2 07.5 09.010.9 13.0 11.3 13.5Zone Controls Zone SensorsAutomatic Changeover One Heat Electrical Data Table ED-1 Unit WiringJobsite Connections Zone Sensors Typical Number Of WiresTSC060 DimensionalDataTSC060 DataTSC060 TSC072-090 TSC102-120 DataTSC072-120 ALL Flanges 1 1/4 31 MM Dimensional TSC060 TSC060 Economizer , Manual or Motorized Fresh Air DamperTSC060 Swing Diameter for Hinged Doors Option Dimensional TSC072-120 Weights Table W-2 Accessory Net Weights1 2 kgTable W-2a Accessory Net Weights1 2 lbs Mechanical Specifications Remote Potentiometer Clogged Filter/Fan Failure SwitchElectric Heaters Roof CurbThermostats Differential Pressure SwitchesComm-5 LonTalk Communication Interface Zone SensorStocking Location 03-03Webb/Mason 02-04 Electronic Only Literature Order NumberFile Number PL-UN-000-RT-PRC016-EN-02-04 Supersedes PL-UN-000-RT-PRC016-EN-12-03

TSC060-120 specifications

The Trane TSC060-120 is a prominent member of Trane's commercial HVAC (Heating, Ventilation, and Air Conditioning) systems, designed to meet the demands of various applications, from small offices to larger commercial venues. This model is part of Trane’s variable refrigerant flow (VRF) systems, which are known for their energy efficiency and flexibility.

One of the standout features of the TSC060-120 is its capacity range, which allows for cooling and heating capacities between 60,000 to 120,000 BTUs. This makes it suitable for diverse environments, adapting well to fluctuating load requirements. Additionally, the unit is designed with a modular approach, meaning that multiple units can be connected to meet larger capacity needs without sacrificing efficiency.

The Trane TSC060-120 incorporates advanced inverter technology, which helps optimize energy consumption by adjusting the compressor speed based on the real-time thermal load of the building. This results in a significant reduction in energy costs and improved comfort levels for occupants. The unit also features a high-efficiency multi-stage filtration system that not only ensures clean air circulation but also contributes to the overall indoor air quality.

The system utilizes a compact and versatile design, allowing for flexible installation options. Its lightweight structure and smaller footprint make it easier to install in tight spaces while still accommodating a powerful performance. The TSC060-120 is designed for quiet operation, which is crucial for noise-sensitive environments, delivering comfort without disruptive sound levels.

In terms of control and monitoring, the TSC060-120 is compatible with Trane's advanced building management systems. This integration allows facility managers to monitor energy usage, schedule maintenance, and control temperatures remotely, enhancing overall operational efficiency.

Moreover, the unit is built with sustainability in mind, using eco-friendly refrigerants that comply with the latest environmental regulations. This commitment to sustainability not only minimizes the ecological footprint but also positions the Trane TSC060-120 as a forward-thinking choice for businesses looking to enhance their energy strategy.

In summary, the Trane TSC060-120 stands out for its efficiency, flexibility, and advanced technology, making it a solid choice for commercial HVAC applications. With its combination of high performance, advanced control features, and commitment to sustainability, it provides an effective solution for modern climate control needs.