Vermont Casting 3370, 3358 Gas Specifications, Gas Inlet and Manifold Pressures, High Elevations

Page 6

Radiance Vent-Free Gas Heater

Gas Specifications

 

 

 

Max.

Min.

 

 

 

Input

Input

 

 

 

Model

Fuel

Gas Control

BTU/h

BTU/h

RUVSODRN

Nat.

Millivolt

35,000

26,000

RUVSODRP

Prop

Millivolt

35,000

26,000

 

 

 

 

 

Firebox weight / shipping

175 lbs.

 

 

 

Gas Inlet and Manifold Pressures

 

 

 

 

Natural

LP (Propane)

Inlet Minimum

 

5.5” w.c.

11” w.c.

Inlet Maximum

 

14” w.c.

14” w.c.

Manifold Pressure

 

3.5” w.c.

10” w.c. (MP)

 

 

 

11” w.c. (RP)

 

 

 

 

Radiance RUVSODRN/RP Vent-Free

Certified to:

ANSI Z21.11.2a-2001

Unvented Heaters

The installation of your Radiance stove must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition. (EXCEPTION: Do not derate this appliance for altitude up to 4,500 feet (1,370m). Maintain the manifold pressure at 3.5” w.c. for Natural Gas and 11.0” w.c. for LP Gas.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohib- ited by state or local codes.

This appliance is to be used only with the type of gas specified on the rating plate which is at- tached to the rear panel. This appliance is not convertible for use with other gases.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.

High Elevations

Input ratings are shown in BTU per hour and are certified without deration from elevations up to 4,500 feet (1,370m) above sea level.

Nuisance outages may occur at altitudes above 4,500 feet (1,370m) if dirt, dust, lint and/or cob- webs are allowed to accumulate on burner and/ or ODS pilot. Monthly inspection and cleaning is recommended for altitudes above 4,500 feet (1,370m)

For elevations above 4,500 feet (1,370m), instal- lations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.

WARNING: Improper installation, adjust- ment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.

Odor During Operation

Neither natural gas nor propane gas give off an odor when burned. The nature of a vent free combustion system, however, is such that odors may occasional- ly be produced during heater operation when impuri- ties exist in the immediate area. Cleaning solutions, paint, solvents, cigarette smoke, candles, adhesives, new carpet or textiles, etc., all can create fumes. These fumes may mix with combustion air and can create odor. Such odors will disappear over time, however the condition can be alleviated by opening a window or otherwise providing additional ventilation to the area.

6

20004555

Image 6
Contents Radiance Table Of Contents Installation & Operating Instructions Carbon Monoxide Poisoning MAY Lead to DeathRadiance Vent Free Gas Heater Dimensions Radiance Vent Free dimensionsHearth Requirements Do not install this heater in a bathroom or bed- roomMinimum Clearances to Combustible Materials Mantel fromHigh Elevations Gas SpecificationsGas Inlet and Manifold Pressures Odor During OperationProvide For Adequate Ventilation Vent Free FeaturesFresh Air Requirements for Combustion Ventilation Unusually Tight ConstructionR N I N G Tools Required Assembly ProceduresHardware Bag Contents Unpacking the RadianceInstall Optional Fan Kit ContentsAssemble the Legs Attach the fan assembly to the fan bracket Install ON/OFF Switch Thermostat Connection OptionalGlass & Catalyst Installation Be sure injector orifices remain at 90 to the baseInstall Log Set Connect the Gas Supply LineAged Logs Complete the Installation Install the left and right rear logs and the right logOperation Flame CharacteristicsFlame & Temperature Adjustment Your First FireTo Turn Off Gas To Heater What to do if YOU Smell GASTroubleshooting No spark at pilot when Ignitor is operatedIgnitor Electrode sparks, but Pilot does not light Pilot lights but Main Burner does not Main Burner shuts off and Pilotflame goes out while in operation Cleaning Procedure MaintenanceFirebox Cleaning and Inspection Glass ReplacementRemove the Combustor Module Clean the Combustor ModuleCatalytic Combustor Replace the Combustor ModuleDescription RuvsodRadiance Vent Free Gas Heater Ruvsod Shell Enamel Part Numbers Radiance Vent Free Gas HeaterOptional Accessories Radiance Vent-Free Gas Heater Radiance Vent-Free Gas Heater Limited Lifetime Warranty If Warranty Service is NEEDED…CFM Specialty Home Products

3358, RUVSOD: 3357, 3370, thru 3379 specifications

Vermont Casting's RUVSOD series, comprising models 3357, 3358, 3370, and 3379, is widely recognized for its exceptional performance and timeless design. These wood stoves are crafted from durable cast iron, ensuring longevity and optimal heat retention. Each model in the RUVSOD line showcases Vermont Casting's commitment to quality, efficiency, and aesthetic appeal.

One of the key features of the RUVSOD series is its remarkable efficiency. With an EPA-certified efficiency rating, these stoves are designed to maximize heat output while minimizing emissions. Users can enjoy a clean-burning fire that not only warms their space but also meets environmental standards. This efficiency is complemented by advanced technologies such as secondary combustion and catalytic converters, which enhance combustion processes and further reduce smoke and particulate emissions.

The RUVSOD models also come equipped with Vermont Casting's unique AirWash system. This innovative feature helps keep the glass door clean, allowing users to enjoy an unobstructed view of the flames. Additionally, the stoves in this series feature a customizable design, allowing consumers to choose from an array of colors and finishes that suit their interior decor. The stylish look of each stove adds a touch of elegance to any living space.

Another standout characteristic of the RUVSOD models is their user-friendly controls. An easy-to-use draft control system makes it simple to adjust the heat output and burn rate according to individual preferences. This ensures that users can maintain a comfortable and cozy atmosphere in their homes throughout the colder months.

In terms of heating capacity, these models can efficiently warm homes of various sizes, which makes them versatile for both small and large spaces. Their high heat output combined with long burn times ensures that users can enjoy hours of continuous heat without the need for frequent refueling.

In summary, the Vermont Casting RUVSOD series—models 3357, 3358, 3370, and 3379—represents the perfect blend of performance, style, and efficiency. With features such as advanced combustion technology, a customizable aesthetic, user-friendly controls, and impressive heating capabilities, these wood stoves stand as a premier choice for those looking to enhance their living space with an effective and attractive heating solution.