LX and LT Pool Heaters

Page 19

 

 

 

 

CAUTION

Keep all objects off the top of the heater, and do not obstruct louvre openings in heater sides. Blocking ventilation air flow may damage the heater and void the warranty.

LAARS

 

 

 

LAARS

 

 

 

 

 

 

 

POOL

POOL/OFF/SPA

 

 

 

 

* SERVICE

Heating

OFF

 

SPA

 

 

 

 

 

Low Pressure

188 °C°F

188 °C°F

 

 

Hi Lim Sw

 

 

 

 

Ext Sw 1

 

 

 

BACKLIGHT

Air Flo Sw

 

 

 

 

AGS

 

 

 

 

Ext Sw 2

 

 

 

 

Temp

 

 

RS Online

 

 

 

 

 

Sensor

 

 

 

RS SERVICE

 

 

 

 

 

Thermostat

Water

 

ON LINE FOR

 

Setting

Temp

 

OPERATION

Pool Spa

 

 

F° C°

WITH

 

 

AquaLinkTM RS

 

 

 

 

CONTROLLER

SELECT

 

 

F°/C°

 

THERMOSTAT SETTINGS

 

 

*SERVICE DIAGNOSTICS-SEE INSIDE FRONT DOOR

a) The LX Control Panel Display

 

b) The LT Control Panel Display

 

Figure 21. Temperature Control Panel

3B. Temperature Controls

The LX and LT heaters have temperature controls that can be set to heat the pool and spa with independent temperature settings. The controls display information to indicate that the heater needs service, and diagnostic information for the service person (see Figure 21). The LX utilizes a liquid crystal display (LCD) screen to display the information while the LT uses indicator lights. The LX Temperature Control also displays pool/spa water temperature and allows for precise temperature settings of the heater.

The controls allow the heater to directly interface with all Waterpik Technologies/Jandy remote control units. The LX offers full remote control capabilities while the LT controls offer limited remote control.

3B-1. Information Displayed

The Model LX displays information on a Liquid Crystal Display (LCD) screen. The temperature control displays the water temperature of the pool or spa as well as the desired temperature (thermostat setting) in either Fahrenheit or Celsius. When there is water flowing through the heater (the filter pump is on), the water temperature is displayed in the right-most of two bar graphs in the center of the screen. This bar graph is labeled as ‘Water Temperature’. The selected thermostatic setting (either Pool or Spa) is displayed as a bar graph directly to the left of the water temperature bar graph. This bar graph is labeled as ‘Thermostat Setting’. Note that when neither thermostat is selected (the heater is in off mode) only the water temperature is displayed.

If there is no water flowing through the heater (the filter pump is off), then only the thermostat setting for the mode selected will be displayed.

The Model LT heater does not display water temperatures or thermostatic settings.

When the heater is unable to operate due to a problem, the temperature control will identify which limit is not satisfied. The Model LX displays this information on the left side of the LCD under the LAARS LX logo. When the gas heater is firing, the LCD displays ‘Heating’ under the LAARS LX logo toward the center of the upper portion of the screen.

The Model LT displays this information by lighting a set of indicator lights located on the front of the control panel.

On the upper right-hand portion of the LCD screen on the Model LX is a selector arrow. Directly to the left of the selector arrow are three positions. They are ‘POOL’, ‘OFF’, and ‘SPA’. This part of the display indicates the mode of operation in which the heater is set.

The mode of operation of the Model LT is shown by two indicator lights labeled "SPA" and "POOL"

Underneath the mode selector on the Model LX display screen is a Backlight indicator. To turn the backlight on, press the middle button to the right of the screen, labeled "Backlight".

Image 21
Contents Installation LX and LT Gas-Fired Pool Table of Contents 2A-1.Special Precautions 1C. Warranty2B. Heater Assembly and Preparation LX and LT Pool Heaters2C. Heater Location 2C-1. Installation Information 2C-3. Flooring Typical Installation2C-2. Installation Clearances 2E. Outdoor Shelter Installation Canada LX and LT Pool Heaters 2D. Outdoor Installation2F-3. Air For Combustion and Ventilation 2F-2. Special Location Requirement2G. Gas Supply and Piping 2G-1. General Instructions 2F-4b.Vent Pipe Sizing InstallationHigh altitude H 2,000 to 4,500 feet 610 to 1370 m ` ` ` ` 2H. Electrical Power 2H-1.General Information 2G-2. Special Precautions for Propane Gas2H-3. Auxiliary Time Clock Wiring 2H-2. BondingRemove Jumper from Terminal Block 2H-4. Remote Operation Model LX OnlyWater Connection as Shipped 2I. Water Piping 2I-1. Reversal of Heater Water ConnectionsLX and LT Pool Heaters Typical Water Piping Piping to Heater 2I-2. Pool/Spa Piping Systems2I-4. Pressure Relief Valve 2I-3. Connections at Heater2I-5. Automatic Chlorinators Chemical Feeders 2J. Start-up and Adjustment 2J-1. Normal Operation2J-4. Adjustment of Water Pressure Switch 2J-2. Start-up2J-3. Gas Pressure Adjustment of Pressure Switch 2J-5. Water Temperature RiseWire or remove the valve handle to prevent tampering 3A. Start-Up Procedure3B-1. Information Displayed 3B. Temperature Controls3B-2. Turning the Heater On or Off 3B-4. Error StatusLX/LT Heater Service Diagnostic Guide 3C. Lighting and Shutdown 3C-1. Lighting the Heater 3C-2. Shutdown3D. Water Chemistry 3D-1. PoolsFor Your Safety Read Before Operating 3E. Spa/Hot Tub Safety Rules 3D-2d. Testing3D-2a. Spa Water Chemistry 3D-2b. Water Changing3G-2. Winterizing 3G. Seasonal Care 3G-1. Spring and Fall Operation3H. Periodic Inspection 3H-1. Owner Inspection4A. General Information 4A-1 Specifications 4A-2 Dimensions3H-2. Professional Inspection 5B. Part Numbers 5A. General Information5C. Exploded View 5C-1 Overview LX and LT Pool Heaters 5C-2 Detail View Limited Warranty