Waterpik Technologies pool/spa heater warranty 5A. General Information, 5B. Part Numbers

Page 29

LX and LT Pool Heaters

Page 27

 

 

 

 

SECTION 5.

Parts List

5A. General Information

To order or purchase parts for the Waterpik Technologies LX or LT pool/spa heater, contact your nearest Waterpik Technologies dealer or distributor. If they cannot supply you with what you need, contact the Customer Service Manager at Waterpik Technologies.

5B. Part Numbers

Key

 

Model

ORDER

No.

Description

No.

PART NO:

 

Water Components

 

 

1

Complete Heat Exchanger (Copper)

250,400

R0326303,05

2

Tube Assy.(Cu), w/ Hdwr & Gaskets

250,400

R0326603,05

3Heat Exchanger Baffles

 

(Set of ten including end baffles)

250,400

R0334403,05

4

Front Header, w/ Hardware & Gaskets

All

R0326900

5

Rear Header, w/ Hardware & Gaskets

All

R0327000

6

By-Pass Assy, w/ Hardware & Gaskets All

R0327100

7

Gasket, Bypass Assy

All

R0336700

8

Spring, Bypass

All

R0327200

9Coupling Nut Kit, w/Compression Ring and Gasket,

 

(Set of two)

All

R0327300

10

Compression Ring w/ Gasket, I/O Header,

 

 

(Set of two)

All

R0327400

11

Gasket, Header (front or rear)

All

R0327500

12

Header Drain Plug w/gasket (Set of 3)

All

R0335900

13*

Heat Exch. Hardware Kit & Gaskets

All

R0327600

 

Gas Components

 

 

14

Burner Tray Weldment

250,400

R0327703,05

15

Burners (Ea.)

All

L0052300

16

Manifold, Gas

250,400

R0327803,05

17

Nat. Orifice (0-3K ft) (Set of 20)

All

R0327900

17

Nat. Orifice (3K-6K ft) (Set of 20)

All

R0328000

17

Nat. Orifice (6K-9K ft) (Set of 20)

All

R0328100

17

LP Orifice (0-5K ft) (Set of 20)

All

R0328200

17

LP Orifice (5K-10K ft) (Set of 20)

All

R0328300

18

Anti-Rotation Bracket

All

R0331800

19

Gas Valve Nat w/ Street Ell

All

R0336800

19

Gas Valve LP w/ Street Ell

All

R0336900

 

Exhaust System

 

 

20

Flue Collector

250,400

R0331703,05

21

Blower Assy.

All

R0329800

22

Gasket w/ Blower Mounting Hardware

All

R0329900

23

Flue Vent

All

R0331500

24

Indoor Vent Collar

250,400

R0331403,05

25

Outdoor Grill

All

R0328500

26*

Vent Hardware Kit

All

R0331600

 

Electrical

 

 

27

Transformer

All

R0328700

28*

Fuse Assy, In-line

All

R0337100

29

Blower Pressure Switch

All

R0302000

30

Temperature Sensor

All

R0011800

Key

 

 

Model

ORDER

 

 

No.

Description

No.

PART NO:

 

Electrical (continued)

 

31

Gasket, Temperature Sensor

All

E0116400

32

Plastic Sleeve, Temperature Sensor

All

10444900

33

Retainer Bracket, Temp. Sensor

All

10447300

34

Screw, Retainer Bracket

All

F0009100

35

Ignition Control

All

R0328800

36

Pressure Switch Assy

All

R0334500

37

Pressure Switch, 2 psi

All

R0013200

38

Siphon Loop

All

R0334600

39

High Limits Set

All

R0023200

40

High Limit 135°F

All

R0022700

41

High Limits 150°F

All

R0023000

42

Harness, High Limit Switch

All

R0334700

43

Retainer Plates, High Limit (Set of 2)

All

R0336500

44

Hot Surface Ignitor

All

R0337000

45

Exhaust Temp. Limit Switch

All

R0329400

46*

Wire Harnesses Complete

All

R0329500

47*

Wire Harness, Power Transformer

All

R0330900

48*

Wire Harness, Ignition Control

All

R0331000

49*

Wire Harness, Gas Valve

All

R0331100

50*

Wire Harness, Safety Loop

All

R0331200

51

Wire Harness, 120 Volt Power Plug

All

R0336200

51

Wire Harness, 240 Volt Power Plug

All

R0336300

52

Wire Harness, 15 Pin Connector

All

R0336400

53

Terminal Block for Fireman’s Switch

All

R0097800

54

Temperature Control W/ Bezel -LX

All

R0329600

54

Temperature Control W/ Bezel -LT

All

R0350500

55

Flame Sense Rod

All

R0334800

56

Fusible Link

All

R0012200

 

Jacket Assy.

 

 

57

Door w/ Latch

250,400

R0330003,05

58

Door Latch Assembly w/ Handle

All

R0334900

59

Cover Panel, Raceway

250,400

R0335103,05

60

Panel, Side, Lower (fits left or right)

All

R0330100

61

Panel, Right Side, Upper

All

R0330200

62

Cover Panel, Exhaust Switch

All

R0336600

63

Panel, Left Side, Upper

All

R0335200

64

Cover Plate, I/O Header Side

All

R0335300

65

Cover Plate, Return Header Side

All

R0335400

66

Cover Panel, Left Side

All

R0335500

67

Rear Panel

250,400

R0330303,05

68

Corner Posts

All

R0330400

69

Top Assy.

250,400

R0330503,05

70

Cover, Temperature Control

All

R0330600

71

Combustion Chamber Assy.

250,400

R0330703,05

72

Base Panel

250,400

R0335603,05

73

Igniter Box Assembly

All

R0335700

74

Bracket, Fusible Link

All

R0337200

 

Optional

 

 

74*

Non Comb. Base

250,400

R0330803,05

75*

Touch-up Paint

All

R0335800

76*

Temperature Rise Measurement Kit

All

R0336000

77

Pressure Relief Valve

All

R0336100

* PARTS NOT SHOWN ON KEY VIEW

NOTES:

1.When ordering a kit for a model 250 specify as R#####-03, When ordering a kit for a model 400 specify as R#####-05,

2.All hardware sets contain all pieces necessary for assembly, including gaskets. Not shown.

3.Gaskets and hardware are included in all kits that involve the removal of a gasket as part of the procedure to replace a part.

Image 29
Contents Installation LX and LT Gas-Fired Pool Table of Contents 2A-1.Special Precautions 1C. Warranty2B. Heater Assembly and Preparation LX and LT Pool Heaters2C-2. Installation Clearances 2C. Heater Location 2C-1. Installation Information2C-3. Flooring Typical Installation 2E. Outdoor Shelter Installation Canada LX and LT Pool Heaters 2D. Outdoor Installation2F-3. Air For Combustion and Ventilation 2F-2. Special Location Requirement2G. Gas Supply and Piping 2G-1. General Instructions 2F-4b.Vent Pipe Sizing InstallationHigh altitude H 2,000 to 4,500 feet 610 to 1370 m ` ` ` ` 2H. Electrical Power 2H-1.General Information 2G-2. Special Precautions for Propane Gas2H-3. Auxiliary Time Clock Wiring 2H-2. BondingRemove Jumper from Terminal Block 2H-4. Remote Operation Model LX OnlyWater Connection as Shipped 2I. Water Piping 2I-1. Reversal of Heater Water ConnectionsLX and LT Pool Heaters Typical Water Piping Piping to Heater 2I-2. Pool/Spa Piping Systems2I-4. Pressure Relief Valve 2I-3. Connections at Heater2I-5. Automatic Chlorinators Chemical Feeders 2J. Start-up and Adjustment 2J-1. Normal Operation2J-3. Gas Pressure 2J-4. Adjustment of Water Pressure Switch2J-2. Start-up Adjustment of Pressure Switch 2J-5. Water Temperature RiseWire or remove the valve handle to prevent tampering 3A. Start-Up Procedure3B-1. Information Displayed 3B. Temperature Controls3B-2. Turning the Heater On or Off 3B-4. Error StatusLX/LT Heater Service Diagnostic Guide 3C. Lighting and Shutdown 3C-1. Lighting the Heater 3C-2. Shutdown3D. Water Chemistry 3D-1. PoolsFor Your Safety Read Before Operating 3E. Spa/Hot Tub Safety Rules 3D-2d. Testing3D-2a. Spa Water Chemistry 3D-2b. Water Changing3G-2. Winterizing 3G. Seasonal Care 3G-1. Spring and Fall Operation3H. Periodic Inspection 3H-1. Owner Inspection3H-2. Professional Inspection 4A. General Information 4A-1 Specifications4A-2 Dimensions 5B. Part Numbers 5A. General Information5C. Exploded View 5C-1 Overview LX and LT Pool Heaters 5C-2 Detail View Limited Warranty