Waterpik Technologies pool/spa heater warranty For Your Safety Read Before Operating

Page 25

LX and LT Pool Heaters

Page 23

 

 

 

 

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury or loss of life.

A.This appliance does not have a pilot light. It is equipped with an ignition device which automatically lights the heater. Do NOT try to light the burners by hand.

B.BEFORE OPERATING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

OPERATING INSTRUCTIONS

1.STOP! Read the safety information above on this label.

2.Set the thermostat to lowest setting and turn appliance switch to "OFF".

3.Turn off all electric power to the appliance.

4.This appliance is equipped with an ignition device which automatically lights the heater. Do not try to light the burners by hand.

5.Remove the heater door.

6.Turn gas control knob clockwise to "OFF".

7.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to next step.

8.Turn gas control knob counterclockwise to "ON".

9.Replace control access panel

10.Turn on all electric power to appliance.

11.*Set thermostat to desired setting and switch appliance from "OFF" to either "POOL" or "SPA".

12.If the appliance will not operate, check that the filter pump is on, the filter is clean and water is flowing to the pool. Otherwise, follow the instructions "To Turn Off Gas To Appliance" and call your service technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

1.* Set the thermostat to lowest setting and switch appliance to "OFF".

2.Turn off all electric power to the appliance if service is to be performed.

3. Turn gas control knob clockwise

to

"OFF".

 

4. Replace control access panel.

Image 25
Contents Installation LX and LT Gas-Fired Pool Table of Contents 2A-1.Special Precautions 1C. Warranty2B. Heater Assembly and Preparation LX and LT Pool Heaters2C-3. Flooring Typical Installation 2C. Heater Location 2C-1. Installation Information2C-2. Installation Clearances 2E. Outdoor Shelter Installation Canada LX and LT Pool Heaters 2D. Outdoor Installation2F-3. Air For Combustion and Ventilation 2F-2. Special Location Requirement2G. Gas Supply and Piping 2G-1. General Instructions 2F-4b.Vent Pipe Sizing InstallationHigh altitude H 2,000 to 4,500 feet 610 to 1370 m ` ` ` ` 2H. Electrical Power 2H-1.General Information 2G-2. Special Precautions for Propane Gas2H-3. Auxiliary Time Clock Wiring 2H-2. BondingRemove Jumper from Terminal Block 2H-4. Remote Operation Model LX OnlyWater Connection as Shipped 2I. Water Piping 2I-1. Reversal of Heater Water ConnectionsLX and LT Pool Heaters Typical Water Piping Piping to Heater 2I-2. Pool/Spa Piping Systems2I-4. Pressure Relief Valve 2I-3. Connections at Heater2I-5. Automatic Chlorinators Chemical Feeders 2J. Start-up and Adjustment 2J-1. Normal Operation2J-2. Start-up 2J-4. Adjustment of Water Pressure Switch2J-3. Gas Pressure Adjustment of Pressure Switch 2J-5. Water Temperature RiseWire or remove the valve handle to prevent tampering 3A. Start-Up Procedure3B-1. Information Displayed 3B. Temperature Controls3B-2. Turning the Heater On or Off 3B-4. Error StatusLX/LT Heater Service Diagnostic Guide 3C. Lighting and Shutdown 3C-1. Lighting the Heater 3C-2. Shutdown3D. Water Chemistry 3D-1. PoolsFor Your Safety Read Before Operating 3E. Spa/Hot Tub Safety Rules 3D-2d. Testing3D-2a. Spa Water Chemistry 3D-2b. Water Changing3G-2. Winterizing 3G. Seasonal Care 3G-1. Spring and Fall Operation3H. Periodic Inspection 3H-1. Owner Inspection4A-2 Dimensions 4A. General Information 4A-1 Specifications3H-2. Professional Inspection 5B. Part Numbers 5A. General Information5C. Exploded View 5C-1 Overview LX and LT Pool Heaters 5C-2 Detail View Limited Warranty