Vermont Casting 2477CE Cleaning the Chimney System, Inspect Regularly, Clean As Required, Stove

Page 20

Dutchwest Non-Catalytic Convection Heater

Cleaning the Chimney System

The chimney system is composed of the chimney and the pipe that connects the stove to the chimney. Inspect the chimney and chimney connector at least twice monthly, and clean if necessary.

When you first begin using the stove, check daily for creosote — a substance that can look like either thick tar or black, crisp flakes. Experience will show how often you need to clean to be safe. The frequency may even vary during the year. In the colder months when the hottest fires producing the least creosote are burned, you may need to clean only every couple of months. During the warmer months when creosote is more likely to result from cooler-burning fires, weekly cleaning may be necessary.

At the very least, inspect the chimney connector and chimney at least once every two months during the heating season to determine if a buildup of creosote or soot has occurred. If a significant layer of creosote has accumulated (3 mm [1/8”] or more), or if soot has accumulated, either should be removed to reduce the risk of a chimney fire. Failure to keep the chimney and connector system clean can result in a serious chimney fire.

The conditions for a chimney fire develop as follows: When wood is burned slowly, it produces tar and other organic vapors which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. Creosote is flammable and, when ignited, makes an extremely hot fire within the flue system which can damage the chimney and overheat adjacent combus- tible material.

To reduce the amount of creosote that may form, re- member to provide adequate air for combustion and to strive for small, intense fires rather than large, smolder- ing ones.

You can never be too safe. Contact your local fire authority for information on what to do in the event of a chimney fire, and have a clearly understood plan on how to handle one.

Inspect Regularly, Clean As Required

Inspect the chimney and chimney connector twice monthly and clean if necessary. Let the stove cool completely before you inspect the chimney. Use a flash- light and mirror to sight up the flue through the chimney clean-out door or chimney connector inspection tee. If no inspection access is available, disconnect the pipe from the stove.

Clean the chimney using a specially designed chimney cleaning brush, the same size and shape as the flue liner, attached to flexible fiberglass rods designed for this purpose. Run the brush up and down the liner so that any deposits fall to the bottom of the chimney where they can be removed through the clean-out door.

Clean the chimney connector by disconnecting the sec- tions, taking them outside, and removing any deposits with a stiff wire brush. You can use a chimney brush of correct size to clean chimney connector pipe. Reinstall the connector sections after cleaning, being sure to secure the individual sections with three sheet metal screws per section.

If you are unable to inspect and/or clean the chimney system yourself, contact your local Dutchwest dealer or hire a qualified chimney sweep in your area to do the job.

Maintenance Schedule

The stove and chimney system should be inspected and maintained by a qualified engineer and include the

following:

The Stove

DAILY:

Clear any ash build-up from around the air holes and combustion flow path in the lower fireback.

Ashes should be removed before they reach the top of the ash pan. Check accumulation at least once a day.

Keep the area around the stove clear of any com- bustible materials such as wood, furniture or cloth- ing.

TWO MONTHS:

Check door handle to be sure it is working properly. Gasketing becomes compressed after a period of time. Adjust handle tightness if necessary.

Check leg bolts and heat shield screws; tighten if necessary.

ANNUAL SPRING CLEANING:

Check gasketing for wear, and replace if necessary.

Remove ashes from the ash pan and replace with a moisture absorbing material (such as kitty litter) to keep the interior of the stove dry.

Clean the dust from the inner sides of bottom, rear or pipe heat shields if your stove is equipped with them. Clean surfaces are better heat reflectors than dirty surfaces.

Touch up the black paint.

20

30003849

Image 20
Contents Non-Catalytic Convection Heater Model 2477CE Table of Contents AccessoriesSpecifications Dutchwest NC Model 2477CEMasonry Chimneys InstallationChimney Types Guidelines for Installing the Chimney Connector Two Types of ConnectorPrefabricated Chimneys Chimney SizeSingle-Wall Connector Double-Wall ConnectorAssembling Single-Wall Chimney Connector Securing the Connector to a Prefabricated ChimneySecuring the Connector to a Masonry Chimney Freestanding InstallationsFireplace Installations Above the Fireplace Fireplace Installations Through the FireplaceWall Pass-Throughs HearthsKeep the Stove a Safe Distance From Surrounding Materials Fireplace InstallationsFloor Protection for Fireplace Installations Connecting Flue Pipe Clearances ClearancesAttach the Legs and Heat Shield AssemblyUnpack the Parts Fan Kit Installation Heater Controls and Features Air Control OperationLoad Doors Damper Function Successful Wood BurningBurn Only High-Quality Fuel Break-in Fires Use the Air Control Settings That Work Best for YouHow to Build and Maintain a Wood Fire Loading Wood Lighting the Fire Reloading and Reviving the FireRemove Ashes Frequently Safe Ash HandlingMaintenance Cleaning the GlassAdjust the Door Latch Test and Repair the Door GasketsAvoid Damaging the Glass Door Panel Damper AdjustmentPrimary Air Control Adjustment Cleaning the Chimney System Inspect Regularly, Clean As RequiredMaintenance Schedule StoveDraft Management Masonry ChimneySteel Chimney Indoor/ Outdoor LocationFlue Sizing Pipe & Chimney LayoutDraft Testing CreosoteBackpuffing Negative PressureDutchwest Convection Heater Dutchwest Convection Heater Dutchwest Non-Catalytic Convection Heater Limited Lifetime Warranty Mhsc