Dutchwest
Installation
SAFETY NOTICE: IF YOUR DUTCHWEST CON- VECTION HEATER IS NOT PROPERLY INSTALLED, OPERATED AND MAINTAINED, A HOUSE FIRE MAY RESULT. FOR SAFETY, FOLLOW ALL INSTALLA- TION, OPERATION AND MAINTENANCE DIREC- TIONS. CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA.
Before you begin the installation, review your plans to confirm that:
•Your stove and chimney connector will be far enough from combustible material to meet all clearance requirements.
•The floor protector is large enough and is construct- ed properly to meet all requirements.
•You have obtained all necessary permits from local authorities.
Your local building official is the final authority for ap- proving your installation as safe and for determining that it meets local and state codes.
The metal label permanently attached to the back of every Dutchwest stove indicates the stove has been tested to current standards. The test standard is EN13240:2001 + A2:2004 for Europe. Clearance and installation information is printed on the metal label at- tached to the rear of the stove. Local authorities gen- erally will accept the label as evidence that, when the stove is installed according to the information on the label and in this manual, the installation meets codes and can be approved.
Codes vary in different areas. Before starting the instal- lation, review your plans with the local building author- ity. Your local dealer can provide any additional informa- tion needed.
IMPORTANT: FAILURE TO FOLLOW THESE IN- STALLATION INSTRUCTIONS MAY RESULT IN A DANGEROUS SITUATION, INCLUDING A CHIMNEY OR HOUSE FIRE. FOLLOW ALL INSTRUCTIONS EXACTLY, AND DO NOT ALLOW MAKESHIFT COM- PROMISES TO ENDANGER PROPERTY AND PER- SONAL SAFETY.
All local regulations, including those referring to national and European standards, need to be com- plied with when installing this stove.
Chimney Types
Your Dutchwest Convection Heater must be connected to a
Whatever kind you use, the chimney and chimney con- nector must be in good condition and kept clean.
Masonry Chimneys
If you use an existing masonry chimney, it must be inspected to ensure safe condition before the stove is installed. Your local professional chimney sweep, building inspector, or fire department official will be able either to make the inspection or to direct you to some- one who can.
An inspection of the chimney must confirm that it has a lining. Do not use an unlined chimney. The chim- ney should also be examined for cracks, loose mortar, other signs of deterioration, and blockage. Repair any defects before the chimney is used with your stove.
Unused openings in an existing masonry chimney must be sealed with masonry to the thickness of the chimney wall, and the chimney liner should be repaired. Open- ings sealed with pie plates or wallpaper are a hazard and should be sealed with mortar or refractory cement. In the event of a chimney fire, flames and smoke may be forced out of these unused thimbles.
The chimney should be thoroughly cleaned before use.
A
The flue and chimney design must meet requirement J2, Part J of the building regulations 2000 (Combustion Appliances and Fuel Storage Systems).
4 | 30003849 |