Vermont Casting manual Specifications, Dutchwest NC Model 2477CE

Page 3

Dutchwest Non-Catalytic Convection Heater

Specifications

Dutchwest NC Model 2477CE

Nominal heat output

11.1 kW (37,800 BTU/hr)1

Minimum flue draught

12 Pa (0.048” WG)

Mean flue gas temp

457° C (855° F)

Efficiency (space heating)

72.0%

Area heated

65-130 sq. m (700-1400 sq. ft.)1

Fuel size/type

483 mm (19”) wood

Flue mass gas flow

7.7 g/s

CO Emissions (@ 13% O2)

900 ppm

Loading

Side and front

Chimney connector

152 mm (6”) diameter

Chimney flue size

152 mm (6”) diameter

Flue exit position

Top or rear

Air control

One

Ash handling system

Removable ash pan

Glass panels

High temperature ceramic

Weight

181 kg (400 lbs.)

Width (leg-to-leg)

622 mm (24¹⁄”)

Depth (leg-to-leg)

445 mm (19¹⁄”)

Height to top of flue collar

775 mm (30¹⁄”)

1.This value can vary depending on how the stove is operated, the type and moisture content of the fuel used, as well as the design, construction and climatic location of your home. Figures shown are based on nominal fuel consumption obtained under laboratory conditions and on average efficiencies.

D

G

F

A

C

E

Model 2477CE

B

A610 mm (24”) B 622 mm (24¹⁄”) C 756 mm (29³⁄”) D 438 mm (17¹⁄”) E 445 mm (17¹⁄”)

F 686 mm

(27”) Center of Flue Collar, Rear Exit

G 775 mm

(30¹⁄”)

Fig. 1 Dutchwest Convection Heater specifications.

30003849

3

Image 3
Contents Non-Catalytic Convection Heater Model 2477CE Accessories Table of ContentsDutchwest NC Model 2477CE SpecificationsInstallation Chimney TypesMasonry Chimneys Chimney Size Guidelines for Installing the Chimney ConnectorTwo Types of Connector Prefabricated ChimneysSecuring the Connector to a Prefabricated Chimney Single-Wall ConnectorDouble-Wall Connector Assembling Single-Wall Chimney ConnectorFireplace Installations Through the Fireplace Securing the Connector to a Masonry ChimneyFreestanding Installations Fireplace Installations Above the FireplaceHearths Wall Pass-ThroughsFireplace Installations Floor Protection for Fireplace InstallationsKeep the Stove a Safe Distance From Surrounding Materials Clearances Connecting Flue Pipe ClearancesAssembly Unpack the PartsAttach the Legs and Heat Shield Fan Kit Installation Operation Heater Controls and Features Air ControlDamper Function Successful Wood Burning Burn Only High-Quality FuelLoad Doors Use the Air Control Settings That Work Best for You How to Build and Maintain a Wood Fire Loading WoodBreak-in Fires Reloading and Reviving the Fire Lighting the FireSafe Ash Handling Remove Ashes FrequentlyTest and Repair the Door Gaskets MaintenanceCleaning the Glass Adjust the Door LatchDamper Adjustment Primary Air Control AdjustmentAvoid Damaging the Glass Door Panel Stove Cleaning the Chimney SystemInspect Regularly, Clean As Required Maintenance ScheduleMasonry Chimney Draft ManagementPipe & Chimney Layout Steel ChimneyIndoor/ Outdoor Location Flue SizingNegative Pressure Draft TestingCreosote BackpuffingDutchwest Convection Heater Dutchwest Convection Heater Dutchwest Non-Catalytic Convection Heater Limited Lifetime Warranty Mhsc