Step 7. Press the gasketed part firmly against its normal mating surface to seat the gasket evenly in its channel. Close and latch the door to do this; close the door on a piece of waxed paper to keep the cement from migrating onto the non-gasketed part, or mask other parts

Step 8. Clean excess cement from around the chan- nel. Let the cement that holds the new gasket dry thoroughly.

Adjust the Door

The door latch may need adjustment as the gasket material compresses over time. The latch engagement may be tightened by removing the shim washers that are under the Latch Plate. (Fig. 29) Remove only one pair at a time. When a tight engagement can no longer be achieved with no shim washers in place, the entire door gasket should be replaced. Use only Vermont Castings part no. 700-0910.

 

Shim Washers

 

Latch Plate

 

ST268

Fig. 29

Remove shim washers to tighten latch engagement.

22

 

The Chimney System

Creosote

Your Seville is designed to reduce creosote buildup significantly. However, regular chimney inspection and maintenance must still be performed. For safety, good stove performance, and to protect your chimney and chimney connector, inspect your chimney and chimney connector on a regular schedule. Clean the system if necessary. Failure to keep the chimney and connector system clean can result in a serious chimney fire.

When wood is burned slowly, it produces tar, organic vapors and moisture that combine to form creosote. The creosote vapors condense in the relatively cool chimney flue. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire within the flue system that can damage the chim- ney and overheat adjacent combustible material.

If you do have a chimney fire, promptly:

Close the thermostat lever.

Get everyone out of the house.

Call the Fire Department.

You should inspect the system every two weeks during the heating season as part of a regular maintenance schedule. To inspect the chimney, let the stove cool completely. Then, using a mirror and a strong light, sight up through the flue collar into the chimney flue. If it is not possible to inspect the flue system in this fashion, the stove must be disconnected to provide better viewing access.

If a significant layer of creosote has accumulated —1/ 8" (3 mm) or more — remove it to reduce the risk of a chimney fire.

Clean the chimney using a brush the same size and shape as the flue liner. Flexible fiberglass rods are used to run the brush up and down the liner, causing any deposits to fall to the bottom of the chimney where they can be removed through the clean-out door.

The chimney connector should be cleaned by disconnecting the sections, taking them outside, and removing any deposits with a stiff wire brush. Reinstall the connector sections after cleaning, being sure to secure the individual sections with sheet metal screws.

If you cannot inspect or clean the chimney yourself, contact your local Vermont Castings, Majestic Products Company Authorized Dealer or hire a professional chimney sweep.

30001490

Image 22
Contents Seville Installation Accessories Table of ContentsIntroduction Specifications Seville, ModelChimneys InstallationMasonry Chimneys Chimney Size Chimney Connector GuidelinesPrefabricated Chimneys Masonry Chimneys, contdSecuring the Single-wall Connector to a Masonry Chimney Double-wall Chimney ConnectorsSingle-wall Chimney Connectors Freestanding InstallationsWall Pass-throughs Connection Above the FireplaceAlternate methods approved by the Nfpa Wall Pass-through with ventilated steel thimble Floor Protection Fireplace Hearth ProtectionSafe Ways To Reduce Clearances Clearance to Surrounding Combustible MaterialsWall Shields Wall shields Seville 1635 Clearance Chart Stove ClearanceStove Installed Stove in Corner Parallel to Wall Alcove InstallationsUnprotected Protected Surfaces Hardware Bag contents AssemblyInstall the Snapstat Unpack the StoveInstall Stove Legs Install the FanInstall the Rheostat Switch Pedestal AssemblyInstall the Outside Air Adapter Attach the Chimney ConnectorHow the Seville Works Use the Air Control Setting that Works Best for YouOperation Burn Only High-Quality WoodStarting and Maintaining a Fire Conditioning Your Stove Burn Rate Primary Air Control Shutter PositionStart a fire with small, dry kindling Ash Disposal Refuel While the Embers Are Still HotSmoke Detectors Maintenance Adjust the Door CreosoteClean the Primary Air Outlet Annual MaintenanceDraft Management Flue Sizing Steel ChimneyInside/Outside Location Pipe & Chimney LayoutNegative Pressure BackpuffingConclusion Seville Woodburning Stove Seville Vermont Castings, Majestic Products