Vanguard Managed Solutions FLAME-MAX VYD18NA, VYBD18N VYD24NA, VYBD24N VYD30NA, VYBD30N VYD36N

Page 25

OWNER’S MANUAL

PARTS LIST

VYD18NA, VYBD18N VYD24NA, VYBD24N VYD30NA, VYBD30N VYD36N

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual.

KEY

 

 

PART NUMBER FOR

 

 

 

 

 

NO.

VYD18NA

VYBD18N

VYD24NA

VYBD24N

VYD30NA

VYBD30N

VYD36N

DESCRIPTION

QTY.

1A

105268-01

105268-02

105268-03

104254-01

Log, Golden Oak

1

1B

103520-01

103336-01

103522-01

Log, Birch

1

2

098276-01

098276-01

098276-01

098276-01

098276-01

098276-01

098276-01

Hex Head Plug,

 

 

 

 

 

 

 

 

 

1/8" NPT

1

3

098249-01

098249-01

098249-01

098249-01

098249-01

098249-01

098249-01

Nut, M5

2

4

102775-04CK

102775-04CK

102775-01CK

102775-01CK

102775-03CK

102775-03CK

102775-03CK

Painted Base

 

 

 

 

 

 

 

 

 

Assembly

1

5

102844-02

102844-02

102844-01

102844-01

102844-01

102844-01

102844-01

Lower Bracket

1

6

102966-02

102966-02

102966-01

102966-01

102966-01

102966-01

102966-01

Upper Bracket

1

7

098867-11

098867-11

098867-11

098867-11

098867-11

098867-11

098867-11

Gas Regulator

1

8

102798-01

102798-01

102798-01

102798-01

102798-01

102798-01

102798-01

Inlet Tube

1

9

102779-03

102779-03

102779-01

102779-01

102779-01

102779-01

102779-01

Outlet Burner Tube

1

10

099056-26

099056-26

099056-16

099056-16

099056-16

099056-16

099056-16

Burner Orifice

 

 

 

 

 

 

 

 

 

Injector

1

11

102843-01

102843-01

102843-01

102843-01

102843-01

102843-01

102843-01

Burner Clip

1

12

102980-01

102980-01

102772-01

102772-01

102772-01

102772-01

102772-01

Burner

1

13

102568-07

102568-07

102568-05

102568-05

102568-05

102568-05

102568-05

Control Valve

1

14

098508-01

098508-01

098508-01

098508-01

098508-01

098508-01

098508-01

Valve Retainer Nut

1

15

098354-01

098354-01

098354-01

098354-01

098354-01

098354-01

098354-01

Control Knob

1

16

102445-01

102445-01

102445-01

102445-01

102445-01

102445-01

102445-01

Piezo Ignitor

1

17

099387-08

099387-08

099387-08

099387-08

099387-08

099387-08

099387-08

Pilot Tube

1

18

098271-07

098271-07

098271-07

098271-07

098271-07

098271-07

098271-07

Ignitor Cable

1

19

104285-01

104285-01

104285-01

104285-01

104285-01

104285-01

104285-01

ODS Pilot

1

20

M11084-38

M11084-38

M11084-38

M11084-38

M11084-38

M11084-38

M11084-38

Screw, Hex Head

11

 

 

 

 

 

 

 

 

(#8-18 x .38)

 

 

 

 

 

 

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

100563-01 100563-01 100563-01

101055-02 101055-02 101055-02

100565-01

100565-01

100565-01

100639-01 100639-01 100639-01

101449-04 101449-04 101449-04

101137-02 101137-02 101137-02

104310-08 104310-08 104310-08

GA6060 GA6060 GA6060

100563-01

101055-02

100565-01

100639-01

101449-04

101137-02

104310-08 GA6060

100563-01

101055-02

100565-01

100639-01

101449-04

101137-02

104310-08 GA6060

100563-01

101055-02

100565-01

100639-01

101449-04

101137-02

104310-08 GA6060

100563-01

101055-02

100565-01

100639-01

101449-04

101137-02

104310-08 GA6060

Warning Plate

Lighting Instructions

Plate

Warning Plate

Fastener

Caution Decal

Control Position

Decal

Hardware Kit

Information Video

Lava Rock

1

1

1

1

1

1

1

1

105187

25

Image 25
Contents Patent Pending What to do if YOU Smell GASVanguard FLAME-MAX Unvented Natural GAS LOG Heater Safety InformationProduct Identification Unpacking Product FeaturesLocal Codes Providing Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsCheck GAS Type InstallationMinimum Wall and Ceiling Clearances see Figure If Not Using Mantel If Using MantelMinimum Noncombustible Material Clearances Eration,Mantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Vintage Oak Log Chassis Connecting to GAS SupplyGolden Oak Birch Model Chassis Pressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Test Pressures In Excess Of 1/2 PsigInstalling Vintage Oak One Installing LogsOperating Heater For Your Safety Read Before LightingLighting Instructions Variable Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterThermostat Control Operation Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesReplacement Parts Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at TopFor Masonry and FACTORY-BUILT Metal Fireplace Optional Positioning of Thermostat Sensing BulbFLAME-MAXVINTAGE OAK LOG Models VYS18NA, VYS24NA VYS30NA Illustrated Parts BreakdownVYS18NA VYS24NA VYS30NA Parts ListODS Pilot VYD18NA, VYBD18N VYD24NA, VYBD24N VYD30NA, VYBD30N VYD36N 511 Part Number for VYD18NTA VYD24NTA VYD30NTA VYD18NTA VYD24NTA VYD30NTASpecifications Service Hints AccessoriesTechnical Service Warranty Information