Vanguard Managed Solutions FLAME-MAX installation manual Specifications

Page 28

VANGUARD FLAME-MAX®

UNVENTED NATURAL GAS LOG HEATER

SPECIFICATIONS

 

Vintage Oak

Vintage Oak

Golden Oak and Birch

 

18" Variable

24" and 30"

18" Variable

 

Manually-

Variable Manually-

Manually-

 

Controlled

Controlled

Controlled

Btu (Variable)

16,000/27,000

16,000/31,500

16,000/30,000

Type Gas

Natural Gas Only

Natural Gas Only

Natural Gas Only

Ignition Piezo

Piezo

Piezo

Piezo

Pressure Manifold

3.5" W.C.

3.5" W.C.

3.5" W.C. .

Inlet Gas Pressure (in. of water)

 

 

 

Maximum

10.5"

10.5"

10.5"

Minimum*

5"

5"

5"

Shipping Weight

36 lbs.

38 lbs.

26 lbs.

 

Golden Oak and Birch

 

 

 

24", 30", and 36"

Golden Oak

Golden Oak

 

Variable

18" Thermostat-

24" and 30"

 

Manually-Controlled

Controlled

Thermostat-Controlled

Btu (Variable)

20,000/39,000

16,000/30,000

20,000/39,000

Type Gas

Natural Gas Only

Natural Gas Only

Natural Gas Only

Ignition Piezo

Piezo

Piezo

Piezo

Pressure Manifold

3.5" W.C.

3.5" W.C.

3.5" W.C

Inlet Gas Pressure (in. of water)

 

 

 

Maximum

10.5"

10.5"

10.5"

Minimum*

5"

5"

5"

Shipping Weight

28 lbs. (24"), 30 lbs. (30")

26 lbs.

28 lbs. (24"), 30 lbs. (30")

 

32 lbs. (36")

 

 

* For input adjustment

 

 

 

28

105187

Image 28
Contents What to do if YOU Smell GAS Patent PendingSafety Information Vanguard FLAME-MAX Unvented Natural GAS LOG HeaterProduct Identification Unpacking Product FeaturesLocal Codes AIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsCheck GAS Type InstallationMinimum Wall and Ceiling Clearances see Figure If Using Mantel If Not Using MantelMinimum Noncombustible Material Clearances Eration,Determining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Vintage Oak Log Chassis Connecting to GAS SupplyGolden Oak Birch Model Chassis Pressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections Test Pressures In Excess Of 1/2 PsigInstalling Logs Installing Vintage Oak OneOperating Heater For Your Safety Read Before LightingLighting Instructions Manual Lighting Procedure Variable Control OperationTo Turn OFF GAS To Appliance Shutting Off HeaterInspecting Burners Thermostat Control OperationPilot Flame Pattern Burner Primary AIR HolesCleaning and Maintenance Replacement PartsTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Top Gas leak. See Warning statement atOptional Positioning of Thermostat Sensing Bulb For Masonry and FACTORY-BUILT Metal FireplaceIllustrated Parts Breakdown FLAME-MAXVINTAGE OAK LOG Models VYS18NA, VYS24NA VYS30NAParts List VYS18NA VYS24NA VYS30NAODS Pilot VYD18NA, VYBD18N VYD24NA, VYBD24N VYD30NA, VYBD30N VYD36N 511 VYD18NTA VYD24NTA VYD30NTA Part Number for VYD18NTA VYD24NTA VYD30NTASpecifications Service Hints AccessoriesTechnical Service Warranty Information