Vanguard Managed Solutions FLAME-MAX installation manual Product Identification, Local Codes

Page 3

OWNER’S MANUAL

PRODUCT IDENTIFICATION

Flame-Max®

Vintage Oak Logs

Burner

One Piece Log Set

 

Piezo Ignitor

Base Assembly

Control Knob

Flame-Max®

Golden Oak Logs

One Piece

Log Set

Piezo Ignitor

Base Assembly

Control Knob

Figure 1 - Product Identification

LOCAL CODES

Flame-Max®

Birch Logs

One Piece

Log Set

Piezo Ignitor

Base Assembly

Control Knob

Flame-Max®

Golden Oak Logs T-Stat

One Piece

Log Set

Piezo Ignitor

Base Assembly

Control Knob

UNPACKING

PRODUCT

FEATURES

OPERATION

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic, dancing yellow flames. This heater is designed for vent-free operation with flue damper closed. It has been tested and ap- proved to ANS Z21.11.2 standard for unvented heaters. State and local codes in some areas prohibit the use of vent-free heaters. Non-thermostat models may also be operated as a vented decorative (ANS Z21.60) product by opening flue damper.

SAFETY PILOT

This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1, also known as NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note: Where listed vented decorative logs are required, thermostat models are not per- mitted.

CAUTION: Do not remove the metal data plates from the grate assembly. The data plates contain important product information.

1.Remove logs and heater base assem- bly from carton. Note: Do not pick up heater base assembly by the burner. This could damage heater. Always handle base assembly by grate.

2.Remove all protective packaging ap- plied to logs and heater for shipment.

3.Check all items for any shipping dam- age. If damaged, promptly inform dealer where you bought heater.

105187

3

Image 3
Contents Patent Pending What to do if YOU Smell GASVanguard FLAME-MAX Unvented Natural GAS LOG Heater Safety InformationUnpacking Product Features Product IdentificationLocal Codes Confined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingInstallation Check GAS TypeMinimum Wall and Ceiling Clearances see Figure Eration, If Using MantelIf Not Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Connecting to GAS Supply Vintage Oak Log ChassisGolden Oak Birch Model Chassis Test Pressures In Excess Of 1/2 Psig Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Checking GAS ConnectionsInstalling Vintage Oak One Installing LogsFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Shutting Off Heater Manual Lighting ProcedureVariable Control Operation To Turn OFF GAS To ApplianceBurner Primary AIR Holes Inspecting BurnersThermostat Control Operation Pilot Flame PatternReplacement Parts Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at TopFor Masonry and FACTORY-BUILT Metal Fireplace Optional Positioning of Thermostat Sensing BulbFLAME-MAXVINTAGE OAK LOG Models VYS18NA, VYS24NA VYS30NA Illustrated Parts BreakdownVYS18NA VYS24NA VYS30NA Parts ListODS Pilot VYD18NA, VYBD18N VYD24NA, VYBD24N VYD30NA, VYBD30N VYD36N 511 Part Number for VYD18NTA VYD24NTA VYD30NTA VYD18NTA VYD24NTA VYD30NTASpecifications Accessories Service HintsTechnical Service Warranty Information