Vanguard Managed Solutions VYS24PWA Installing Logs, Pressure Testing Heater Gas Connections

Page 13

OWNER’S MANUAL

INSTALLATION

Continued

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Fig- ure 16).

2.Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve.

3.Check all joints from propane/LP sup- ply tank to equipment shutoff valve (see Figure 17). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Propane/LP Supply Tank

Equipment Shutoff

Control Valve Location

Valve

Pressure Testing Heater Gas Connections

Figure 17 - Checking Gas Joints

INSTALLING LOGS

One Piece Log Set

 

1.Open equipment shutoff valve (see Fig- ure 16).

2.Open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to control valve (see Figure 17). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 14 through 16). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 15).

Equipment

Shutoff Open

Valve

Closed

Figure 16 - Equipment Shutoff Valve

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, re- position logs according to the log installation instructions in this manual. Flames contacting logs will create soot.

It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place one-piece log set on grate to fit as illustrated in Figure 18. Make sure middle section at bottom of log set is seated into “U”-shaped cutout in cen- ter of chassis (see Figure 18). Log will fit securely on chassis. IMPORTANT: Make sure log does not cover any burner ports.

2.Place lava rock around base of heater.

 

Burner

Chassis

"U"-shaped

 

Cutout in

 

Chassis

Figure 18 - Installing Vintage Oak One- Piece Log Set

Burner

One Piece Log Set

Ports

 

Figure 19 - Installing Vintage Oak One- Piece Log set (Top View)

105190

13

Image 13
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSave this manual for future reference Vanguard Unvented PROPANE/LP GAS LOG Heater Safety InformationTo P Providing Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsInstallation InstallationCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsMaterial Clearances Minimum NoncombustibleFloor Clearances Mantel ClearancesInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Area of Various Standard Round FluesConnecting to GAS Supply Installing GWMS2 Optional Wall Mounted SwitchItems Included for Installation Connecting To Log SetChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Installing LogsOperating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Pilot Flame Pattern Inspecting BurnersBurner Primary AIR Holes Main BurnerObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement at Specifications Wiring DiagramReplacement Parts Service HintsCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Vintage OAK LOG Models VYS18PWA, VYS24PWA VYS30PWA Illustrated Parts BreakdownVintage OAK LOG Models VYS18PWA, VYS24PWA, VYS30PWA Parts ListAccessories 105190 Warranty Information

VYS30PWA, VYS24PWA specifications

Vanguard Managed Solutions, particularly the VYS30PWA and VYS24PWA models, represent advanced innovations in the field of managed solutions. These models cater to diverse industries, providing scalable and efficient operational frameworks.

The VYS30PWA model is characterized by its robust performance and adaptability. It is designed to handle complex workloads with ease, making it suitable for environments where efficiency and reliability are paramount. The backbone of this unit is its high-capacity processing power, which allows it to support multiple simultaneous operations without significant lag. This is particularly beneficial for organizations that require real-time data processing and analytics capabilities.

On the other hand, the VYS24PWA model offers a more compact solution without compromising on performance. This model is ideal for smaller enterprises or specific project setups where space is limited but functionality cannot be sacrificed. It ensures optimal resource usage while maintaining high-speed connectivity and data flow. Its design enables seamless integration with existing systems, reducing the need for extensive modifications.

Both models incorporate cutting-edge technologies such as cloud integration and advanced analytics. The cloud capability allows users to leverage a flexible workspace, where data and applications can be accessed from any location, fostering remote collaboration and improving productivity. Furthermore, by utilizing cloud-based analytics, organizations can gain actionable insights into their operations, driving informed decision-making.

Security is also a top priority for Vanguard Managed Solutions. Both the VYS30PWA and VYS24PWA feature advanced encryption protocols and are equipped with state-of-the-art security measures to safeguard sensitive information. This focus on security ensures that businesses can operate with peace of mind in an increasingly digital landscape.

In terms of characteristics, both models are built with user-friendliness in mind. Their interfaces are designed to facilitate easy navigation, ensuring that employees can quickly adapt and utilize the systems effectively. Additionally, support and maintenance options are built into the package, allowing organizations to benefit from ongoing assistance as needed.

Overall, Vanguard Managed Solutions VYS30PWA and VYS24PWA are tailored to meet the evolving needs of modern businesses. With a combination of power, versatility, and security, they stand out as essential tools for organizations looking to streamline their operations and enhance overall productivity.