Vanguard Managed Solutions VYS30PWA, VYS24PWA Wiring Diagram, Specifications, Replacement Parts

Page 20

VANGUARD

UNVENTED PROPANE/LP GAS LOG HEATER

WIRING DIAGRAM

Note: For proper operation of optional ac- cessories, the wires from the switch to the control must be connected exactly as shown.

OFF

ON

Thermopile

SPECIFICATIONS

Vintage Oak

Vintage Oak

18"

24” and 30”

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Techni- cal Service Department at 1-800-323-5190. When calling DESA International, have ready

your name and address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the defec- tive part to the factory.

Btu (Variable)

17,500/27,000

19,000/31,500

Type Gas

Propane/LP Only

Propane/LP Only

Ignition

Piezo

Piezo

Pressure Manifold

8.0" W.C.

8.0" W.C.

Inlet Gas Pressure (in. of water)

 

 

Maximum

14"

14"

Minimum*

11"

11"

Shipping Weight

28 lbs.

30 lbs. (24")/32 lbs. (30")/

* For input adjustment

 

 

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information. When calling DESA Interna- tional, have ready

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni- cal Service Department at 1-800-DESA LOG (1-800-337-2564).

model number of your heater

the replacement part number

When Gas Quality Is Bad

pilot will not stay lit

burners will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.

You can also visit DESA International’s technical services web site at www.desatech.com.

20

105190

Image 20
Contents Save this manual for future reference OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Safety Information Vanguard Unvented PROPANE/LP GAS LOG HeaterTo P AIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation InstallationCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsMinimum Noncombustible Material ClearancesMantel Clearances Floor ClearancesInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Area of Various Standard Round FluesInstalling GWMS2 Optional Wall Mounted Switch Connecting to GAS SupplyItems Included for Installation Connecting To Log SetPressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Logs Pressure Testing Heater Gas ConnectionsLighting Instructions For Your Safety Read Before LightingOperating Heater Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Inspecting Burners Pilot Flame PatternBurner Primary AIR Holes Main BurnerTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement at Wiring Diagram SpecificationsReplacement Parts Service HintsLogs Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Illustrated Parts Breakdown Vintage OAK LOG Models VYS18PWA, VYS24PWA VYS30PWAParts List Vintage OAK LOG Models VYS18PWA, VYS24PWA, VYS30PWAAccessories 105190 Warranty Information

VYS30PWA, VYS24PWA specifications

Vanguard Managed Solutions, particularly the VYS30PWA and VYS24PWA models, represent advanced innovations in the field of managed solutions. These models cater to diverse industries, providing scalable and efficient operational frameworks.

The VYS30PWA model is characterized by its robust performance and adaptability. It is designed to handle complex workloads with ease, making it suitable for environments where efficiency and reliability are paramount. The backbone of this unit is its high-capacity processing power, which allows it to support multiple simultaneous operations without significant lag. This is particularly beneficial for organizations that require real-time data processing and analytics capabilities.

On the other hand, the VYS24PWA model offers a more compact solution without compromising on performance. This model is ideal for smaller enterprises or specific project setups where space is limited but functionality cannot be sacrificed. It ensures optimal resource usage while maintaining high-speed connectivity and data flow. Its design enables seamless integration with existing systems, reducing the need for extensive modifications.

Both models incorporate cutting-edge technologies such as cloud integration and advanced analytics. The cloud capability allows users to leverage a flexible workspace, where data and applications can be accessed from any location, fostering remote collaboration and improving productivity. Furthermore, by utilizing cloud-based analytics, organizations can gain actionable insights into their operations, driving informed decision-making.

Security is also a top priority for Vanguard Managed Solutions. Both the VYS30PWA and VYS24PWA feature advanced encryption protocols and are equipped with state-of-the-art security measures to safeguard sensitive information. This focus on security ensures that businesses can operate with peace of mind in an increasingly digital landscape.

In terms of characteristics, both models are built with user-friendliness in mind. Their interfaces are designed to facilitate easy navigation, ensuring that employees can quickly adapt and utilize the systems effectively. Additionally, support and maintenance options are built into the package, allowing organizations to benefit from ongoing assistance as needed.

Overall, Vanguard Managed Solutions VYS30PWA and VYS24PWA are tailored to meet the evolving needs of modern businesses. With a combination of power, versatility, and security, they stand out as essential tools for organizations looking to streamline their operations and enhance overall productivity.