Vanguard Managed Solutions VYS24PWA, VYS30PWA installation manual Parts List

Page 23

OWNER’S MANUAL

PARTS LIST

VINTAGE OAK LOG MODELS VYS18PWA, VYS24PWA, VYS30PWA

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual.

 

KEY

PART NUMBER FOR

 

 

 

NO.

VYS18PWA

VYS24PWA

VYS30PWA

DESCRIPTION

QTY.

1

105185-01

105185-02

105185-03

Log, 1 Piece

1

2

103778-01

103778-01

103778-01

ODS Pilot (LP)

1

3

098249-01

098249-01

098249-01

ODS Nut

2

4

105197-02

105197-02

105197-02

Burner Outlet Tube

1

5

098265-02

098265-02

098265-02

Elbow Connector

1

6

102843-01

102843-01

102843-01

Burner Clip

1

7

099056-21

099056-19

099056-19

Burner Orifice Injector

1

8

102966-01

102966-01

Upper Bracket

1

9

102963-01

102773-01

102773-01

Burner

1

10

099387-13

099387-09

099387-09

Pilot Tube

1

11

103781-02

103781-02

103781-02

Gas Control Valve

1

12

103345-02

103345-01

103345-01

Lower Bracket

1

13

M11084-38

M11084-38

M11084-38

Screw, #8 x .38

7

14

102775-10CK

102775-06CK

102775-06CK

Painted Base Assy

1

15

098271-07

098271-07

098271-07

Ignitor Cable

1

16

102445-01

102445-01

102445-01

Piezo Ignitor

1

17

103587-02CK

103587-02CK

103587-02CK

Plate, Switch

1

18

104099-01

104099-01

104099-01

Heat Shield

1

19

098304-01

098304-01

098304-01

Screw

2

20

103784-02

103784-02

103784-02

Flame Adjustment Knob

1

21

103784-01

103784-01

103784-01

Off-Pilot-On Knob

1

22

M12461-26

M12461-26

M12461-26

Screw, Hex Slt Wsr

 

 

 

 

 

 

10-32 x .38

4

23

103284-02

103284-02

103284-02

Wiring Harness

 

24

099998-01

099998-01

099998-01

Switch

1

 

 

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

 

100563-01

100563-01

100563-01

Warning Plate

1

 

103877-01

103877-01

103877-01

Lighting Instructions

 

 

 

 

 

Plate

1

 

100565-01

100565-01

100565-01

Warning Plate Fastener

1

 

100693-01

100639-01

100639-01

Caution Decal

1

 

101137-02

101137-02

101137-02

Hardware Kit

1

 

104310-08

104310-08

104310-08

Information Video

1

 

GA6060

GA6060

GA6060

Lava Rock

1

 

 

 

 

 

 

105190

23

Image 23
Contents Save this manual for future reference OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Vanguard Unvented PROPANE/LP GAS LOG Heater Safety InformationTo P Confined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingMinimum Fireplace Clearance to Combustible Materials InstallationInstallation Check GAS TypeMaterial Clearances Minimum NoncombustibleFloor Clearances Mantel ClearancesArea of Various Standard Round Flues Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededConnecting To Log Set Installing GWMS2 Optional Wall Mounted SwitchConnecting to GAS Supply Items Included for InstallationChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Installing LogsLighting Instructions For Your Safety Read Before LightingOperating Heater Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Main Burner Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement at Service Hints Wiring DiagramSpecifications Replacement PartsLogs Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Vintage OAK LOG Models VYS18PWA, VYS24PWA VYS30PWA Illustrated Parts BreakdownVintage OAK LOG Models VYS18PWA, VYS24PWA, VYS30PWA Parts ListAccessories 105190 Warranty Information

VYS30PWA, VYS24PWA specifications

Vanguard Managed Solutions, particularly the VYS30PWA and VYS24PWA models, represent advanced innovations in the field of managed solutions. These models cater to diverse industries, providing scalable and efficient operational frameworks.

The VYS30PWA model is characterized by its robust performance and adaptability. It is designed to handle complex workloads with ease, making it suitable for environments where efficiency and reliability are paramount. The backbone of this unit is its high-capacity processing power, which allows it to support multiple simultaneous operations without significant lag. This is particularly beneficial for organizations that require real-time data processing and analytics capabilities.

On the other hand, the VYS24PWA model offers a more compact solution without compromising on performance. This model is ideal for smaller enterprises or specific project setups where space is limited but functionality cannot be sacrificed. It ensures optimal resource usage while maintaining high-speed connectivity and data flow. Its design enables seamless integration with existing systems, reducing the need for extensive modifications.

Both models incorporate cutting-edge technologies such as cloud integration and advanced analytics. The cloud capability allows users to leverage a flexible workspace, where data and applications can be accessed from any location, fostering remote collaboration and improving productivity. Furthermore, by utilizing cloud-based analytics, organizations can gain actionable insights into their operations, driving informed decision-making.

Security is also a top priority for Vanguard Managed Solutions. Both the VYS30PWA and VYS24PWA feature advanced encryption protocols and are equipped with state-of-the-art security measures to safeguard sensitive information. This focus on security ensures that businesses can operate with peace of mind in an increasingly digital landscape.

In terms of characteristics, both models are built with user-friendliness in mind. Their interfaces are designed to facilitate easy navigation, ensuring that employees can quickly adapt and utilize the systems effectively. Additionally, support and maintenance options are built into the package, allowing organizations to benefit from ongoing assistance as needed.

Overall, Vanguard Managed Solutions VYS30PWA and VYS24PWA are tailored to meet the evolving needs of modern businesses. With a combination of power, versatility, and security, they stand out as essential tools for organizations looking to streamline their operations and enhance overall productivity.