Vanguard Heating Gas Log Heater installation manual Technical Service, Statement at top

Page 28

TROUBLE- SHOOTING

Continued

WARNING

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED

POSSIBLE

 

PROBLEM

CAUSE

REMEDY

 

 

 

Heater produces a

1. Metal expanding while

1. This is common with

clicking/ticking noise

heating or contracting

most heaters. If noise is

just after burner is lit or

while cooling

excessive, contact

shut off

 

qualified service person

Heater produces

1.

Heater burning

vapors

unwanted odors

 

from

paint, hair

spray,

 

 

glues,

cleaners,

chemi-

 

 

cals, new carpet, etc. (See

 

 

IMPORTANT statement

 

 

above)

 

 

2.

Gas leak. See Warning

 

 

statement at top of

 

 

page

 

 

1.Open window and ventilate room. Stop using odor causing products while heater is running

2.Locate and correct all leaks (see Checking Gas Connections, page 18)

28

TECHNICAL SERVICE

Heater shuts off in use

1.

Not enough fresh air is

1.

Open window and/or

 

(ODS operates)

 

available

 

door for ventilation

 

 

2.

Low line pressure

2.

Contact local natural

 

 

 

 

 

gas company

 

 

3.

ODS/pilot is partially

3.

Clean ODS/pilot (see

 

 

 

clogged

 

Cleaning and Mainte-

 

 

 

 

 

nance, page 25)

 

 

 

 

 

 

 

Gas odor even when

1.

Gas leak. See Warning

1.

Locate and correct all

 

control knob is in OFF

 

statement at top of

 

leaks (see Checking Gas

 

position

 

page

 

Connections, page 18)

 

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

 

Gas odor during

1.

Foreign matter between

1. Take apart gas tubing and

 

combustion

 

control valve and burner

 

remove foreign matter

 

 

2.

Gas leak. See Warning

2.

Locate and correct all

 

 

 

statement at top of

 

leaks (see Checking Gas

 

 

 

page

 

Connections, page 18)

 

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).

103515

Image 28
Contents OWNER’S Operation and Installation Manual FLAME-MAXDesign Log DesignContents Safety Information Safety InformationProduct Identification Features Local CodesUnpacking ProductAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installing Check GAS TypeLOG Sizing Requirements Minimum Fireplace Clearance To Combustible MaterialsMinimum Wall and Ceiling Clearances see Figure Minimum Non Combustible Material Clearances If Using Mantel Installing Installing Damper Clamp Accessory for Vented Operation Attaching Damper ClampInstalling Heater Base Assembly Installation Items NeededAttaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS Supply Installation Items NeededChecking GAS Connections Gas ConnectionPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than 1/2 PsigInstalling Logs For Vintage Oak Log ModelInstalling Golden Oak or Birch One-Piece Log Set For Golden Oak or Birch ModelsFor Your Safety Read Before Lighting Operating HeaterVariable Control Operation Operating Heater Inspecting Burners Pilot Flame PatternTrouble Shooting Qualified service person should service and repair heaterODS/PILOT and Burner LogsMaintenance, TROUBLE- ShootingRefer to Air for Com Technical Service Statement at topReplacement Parts ServiceHints Illustrated Parts Breakdown Parts List KEY Part Number for VYS18N VYS24N Description QTYFlame-Max  Golden Oak Birch Log Models VYD24N and VYBD24N Parts List Accessories Valve GA5010Hood GA6050 Hood GA6052103515 Warranty Information Keep this Warranty