Vanguard Heating Gas Log Heater AIR for Combustion and Ventilation, Unusually Tight Construction

Page 6

AIR FOR COMBUSTION AND VENTILATION

Continued

6

PROVIDING ADEQUATE VENTILATION

The following is exerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications:

1. Unusually Tight Contruction; 2. Unconfined Space; 3. Confined Space.

The information on pages 5 through 8 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construc- tion, you must provide additional fresh air.

Unusually tight construction is defined as construction where:

a.walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6x10-11per pa•sec•m2) or less with openings gasketed or sealed and

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide addi- tional fresh air. See Ventilation Air From Outdoors, page 8.

If your home does not meet all of the three criteria above, proceed to page 7.

Confined and Unconfined Space

The National Fuel Gas Code (ANSIZ223.1, 1992 Section 5.3) defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.

*Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.

103515

Image 6
Contents Design OWNER’S Operation and Installation ManualFLAME-MAX Log DesignContents Safety Information Safety InformationProduct Identification Unpacking FeaturesLocal Codes ProductUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installing Check GAS TypeMinimum Fireplace Clearance To Combustible Materials LOG Sizing RequirementsMinimum Wall and Ceiling Clearances see Figure Minimum Non Combustible Material Clearances If Using Mantel Installing Installing Damper Clamp Accessory for Vented Operation Attaching Damper ClampInstalling Heater Base Assembly Installation Items NeededAttaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS Supply Installation Items NeededChecking GAS Connections Gas ConnectionPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than 1/2 PsigInstalling Logs For Vintage Oak Log ModelInstalling Golden Oak or Birch One-Piece Log Set For Golden Oak or Birch ModelsFor Your Safety Read Before Lighting Operating HeaterVariable Control Operation Operating Heater Inspecting Burners Pilot Flame PatternODS/PILOT and Burner Trouble ShootingQualified service person should service and repair heater LogsMaintenance, TROUBLE- ShootingRefer to Air for Com Technical Service Statement at topService Replacement PartsHints Illustrated Parts Breakdown Parts List KEY Part Number for VYS18N VYS24N Description QTYFlame-Max  Golden Oak Birch Log Models VYD24N and VYBD24N Parts List Hood GA6050 AccessoriesValve GA5010 Hood GA6052103515 Warranty Information Keep this Warranty