Vanguard Heating 18, 36" Flame Oak Log, 24, 30 installation manual Illustrated Parts Breakdown

Page 22

VANGUARD FLAME-MAX®

UNVENTED PROPANE/LP GAS LOG HEATER

ILLUSTRATED

PARTS

BREAKDOWN

FLAME-MAX™ GOLDEN OAK

LOG MODELS VYD18PR,

VYD24PR, VYD30PR, AND

VYD36PR

*Note: The Golden Oak Log (104254-01)

 

for the VYD36PR model differs slightly

 

from the log shown.

1

2

10 3

6

7

9

8

12 10

13

4

5

11

14

23

18

I

H

LO

 

O

NO

F

F

 

TOL P

17

15

16 19

24

19

 

IH

 

20

L

O

NO

FF

 

 

TO

2113

13

22

22

104309

Image 22
Contents 18, 24, 30, and 36 Remote Ready Model OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Save this manual for future referenceSafety Information Vanguard FLAME-MAX Unvented PROPANE/LP GAS LOG HeaterRemote Control Accessories Local Codes Unpacking Product FeaturesProduct Identification Unusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Building Ventilation AIRVentilation Air From Inside Ventilation Air From OutdoorsCheck GAS Type InstallationInstallation Clearances Minimum Fireplace Clearance to Combustible MaterialsIf Using Mantel If Not Using MantelMinimum Noncombustible Material Clearances Floor Clearances Determining Minimum Mantel Clear- ance When using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Chimney Minimum Permanent Height ft Flue Opening sq. insConnecting to GAS Supply Attaching Flexible Gas Hose to HeaterChecking GAS Connections Pressure Testing Heater Gas ConnectionsPressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PsigInstalling Logs Installing Golden Oak One-Piece Log SetOperating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Burner Primary AIR Holes Inspecting BurnersPilot Flame Pattern Main BurnerTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement at TopService Hints Wiring Diagram Replacement PartsSpecifications Technical ServiceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Illustrated Parts Breakdown Parts List VYD18PR, VYD24PR, VYD30PR, and VYD36PRAccessories 104309 Warranty Information