INSTALLING LOGS

One Piece Log Set

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, re- position logs according to the log installation instructions in this manual. Flames contacting logs will create soot.

Chassis

Middle

Section at

Bottom of Log

Set

Burner

"U"-shaped Cutout in Chassis

It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place one-piece log set on grate to fit as illustrated in Figure 17. Make sure middle section at bottom of log set is seated into “U”-shaped cutout in cen- ter of chassis (see Figure 17). Note: 36” model has more features but fits on the chassis the same. Log will fit securely on chassis. IMPORTANT: Make sure log does not cover any burner ports.

2.Place lava rock around base of heater.

Figure 17 - Installing Golden Oak One-Piece Log Set

Burner

 

Ports

One Piece Log Set

Figure 18 - Installing Golden Oak One-Piece Log set (Top View)

104309

13

Image 13
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation Manual18, 24, 30, and 36 Remote Ready Model Save this manual for future referenceVanguard FLAME-MAX Unvented PROPANE/LP GAS LOG Heater Safety InformationRemote Control Accessories Local Codes Unpacking Product FeaturesProduct Identification Providing Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsInstallation Clearances InstallationCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsIf Using Mantel If Not Using MantelMinimum Noncombustible Material Clearances Mantel Clearances Determining Minimum Mantel Clear- ance When using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Chimney Minimum Permanent Height ft Flue Opening sq. insAttaching Flexible Gas Hose to Heater Connecting to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections Test Pressures In Excess Of 1/2 PsigInstalling Golden Oak One-Piece Log Set Installing LogsOperating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Pilot Flame Pattern Inspecting BurnersBurner Primary AIR Holes Main BurnerObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Top Gas leak. See Warning statement atSpecifications Wiring Diagram Replacement PartsService Hints Technical ServiceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Illustrated Parts Breakdown VYD18PR, VYD24PR, VYD30PR, and VYD36PR Parts ListAccessories 104309 Warranty Information