Graco 308149P important safety instructions Hydraulic-Poweredpumps, Installation

Models: 308149P

1 38
Download 38 pages 47.39 Kb
Page 10
Image 10
(HYDRAULIC-POWERED PUMPS)

Installation

(HYDRAULIC-POWERED PUMPS)

NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing.

Accessories are available from your Graco . If you supply your own accessories, be sure they are ade- quately sized and pressure-rated to meet the system’s requirements.

The Typical Installation shown in Fig. 4 is only a guide for selecting and installing system components and accessories. Contact your Graco distributor for assis- tance in designing a system to suit your particular needs.

Fig. 4 CAUTION

It is very important to keep the hydraulic supply system clean at all times. Be sure that all hydraulic fluid lines are absolutely clean. Blow out the lines with air and flush thoroughly with solvent before connecting to the hydraulic motor, to avoid introduc- ing harmful contaminants into the motor. Plug the hydraulic lines immediately when they are discon- nected.

Do not exceed 37.8 liter/min (10 gpm) hydraulic oil volume to the motor, to avoid pump stalling.

For optimum pump performance, keep the tempera- ture of the hydraulic oil below 54_ C (130_ F)

KEY

APump

B200 Liter (55 Gallon) Air-Powered Ram

CHydraulic Supply Line

DHydraulic Return Line

EDrain Line (from pressure reducing valve)

FPressure Gauge

GFlow Control Valve

HPressure Reducing Valve

JAccumulator

KDrain Line (from motor drip pan)

LFluid Regulator

MFluid Drain Valve (required)

NElectrically Conductive Fluid

Supply Hose

H

PFluid Shutoff Valve

R Gun/Valve Swivel

J

SAirless Spray Gun or Dispensing Valve

TRam Air Regulator

UHydraulic Supply Line Shutoff Valve

VHydraulic Return Line Shutoff Valve

YGround Wire (required, see page 7 for installation instructions)

AAHydraulic Return Line Filter

AIR FILTER FOR RAM

AIR SHUTOFF VALVE FOR RAM

MAIN AIR LINE

FLUID HEADER PIPE

 

 

(3 in. Diameter)

F U V

 

 

A

 

 

B

 

 

Y

L P

L P

 

G

T

 

 

 

C

 

 

HYDRAULIC

 

 

 

D

 

 

 

POWER SUPPLY

 

 

 

 

 

 

 

 

E

S R

M

M

 

 

 

 

 

N

N

 

 

M

S

R

 

 

 

 

 

AA

 

 

 

DRAINAGE

K

01178

CONTAINER

 

 

Fig. 4

10 308149