(Model 222901 Quiet King Pump)

Technical Data

(Model 222901 Quiet King Pump)

Ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24:1 (Quiet King Air Motor) Maximum fluid working pressure . . . . . . . . . . . . . . . . . . . . . . . . . . 16.6 MPa, 166 bar (2400 psi) Maximum air input pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.7 MPa, 7 bar (100 psi) Pump cycles per 3.8 liters (1 gal.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Recommended pump speed for continuous operation . . . . . . . . . . . . . . . . . . 50 cycles per min Maximum flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23.75 liters/min (7.5 gpm) at 50 cycles/min Air motor piston effective area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 506 cm@ (78.5 in.@) Stroke length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 mm (4.75 in.) Displacement pump effective area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 cm@ (3.255 in.@) Maximum pump operating temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65.5_C (150_F) Air inlet size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/4 npsm(f) Fluid outlet size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–1/2” npt(m) Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approx. 73 kg (160 lb) Displacement Pump Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approx. 37 kg (81 lb) Wetted parts . . . . . . . . . . . . . . . . Carbon Steel; Chrome, Zinc, and Electroless Nickel Plating;

304 and 17–4 PH Grades of Stainless Steel; E52100 Alloy Steel; Ductile Iron; Acetal; PTFE; Ultra-High Molecular Weight Polyethylene

KEY: Fluid Outlet Pressure – Black Curves

A

0.63 MPa, 6.3 bar (90 psi) Air Pressure

Air Consumption – Gray Curves

B

0.49 MPa, 4.9 bar (70 psi) Air Pressure

 

C

0.28 MPa, 2.8 bar (40 psi) Air Pressure

NOTE: Recommended pump speed for continuous operation (to shaded area): 50 cpm

psi

 

 

 

 

 

 

psi

 

 

 

 

 

 

bar

 

cycles/min

 

 

scfm

bar

 

cycles/min

 

 

scfm

MPa

16

32

48 50

64

80

m#/min

MPa

8

16

24

32

40

m#/min

 

 

2000

 

 

 

 

 

300

2000

 

 

 

 

 

300

140

A

 

 

 

 

8.40

140

 

 

 

 

 

8.40

14.0

 

 

 

 

 

 

14.0

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1600

 

 

 

A

 

240

1600

 

 

 

 

 

240

112

B

 

 

 

 

6.72

112

 

 

 

 

 

6.72

11.2

 

 

 

 

 

11.2

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1200

 

 

 

 

 

180

1200

 

 

 

 

 

180

 

 

 

 

 

5.04

 

 

 

 

 

5.04

84

 

 

 

B

 

84

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8.4

 

 

 

 

 

 

8.4

 

 

 

 

 

 

800

C

 

 

 

 

120

800

C

 

 

 

 

120

 

 

 

 

 

 

 

 

3.36

56

 

 

 

C

 

3.36

56

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

5.6

 

 

 

 

 

 

5.6

 

 

 

 

 

400

 

 

 

 

 

60

400

 

 

 

 

 

60

 

 

 

 

 

1.68

 

 

 

C

 

1.68

28

 

 

 

 

 

28

 

 

 

 

2.8

 

 

 

 

 

 

2.8

 

 

 

 

 

 

0

 

 

 

 

 

 

0

 

 

 

 

 

 

gpm 0

2

4

6

8

10

gpm 0

1

2

3

4

5

 

liters/min

7.6

15.2

22.8

30.4

38.0

liters/min

3.8

7.6

11.4

15.2

19.0

 

 

 

FLUID FLOW

 

 

 

 

 

FLUID FLOW

 

 

 

 

(TEST FLUID: 100,000 CENTIPOISE SEALANT)

 

 

(TEST FLUID: 4,000,000 CENTIPOISE SILICON)

 

To find Fluid Outlet Pressure (MPa/bar/psi) at a specific fluid flow

To find Pump Air Consumption (m#/min or scfm) at a specific fluid

(lpm/gpm) and operating air pressure (MPa/bar/psi):

flow (lpm/gpm) and air pressure (MPa/bar/psi):

1.

Locate desired flow along bottom of chart.

1.

Locate desired flow along bottom of chart.

2.

Follow vertical line up to intersection with selected fluid outlet

 

 

 

pressure curve (black). Follow left to scale to read fluid outlet

2.

Read vertical line up to intersection with selected air consumption

 

pressure.

 

curve (gray). Follow right to scale to read air consumption.

308149 33

Page 33
Image 33