Graco 308149P important safety instructions Model 222940 Premier Pump, Technical Data

Models: 308149P

1 38
Download 38 pages 47.39 Kb
Page 34
Image 34
(Model 222940 Premier Pump)

Technical Data

(Model 222940 Premier Pump)

Ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39:1 (Premier Air Motor) Maximum fluid working pressure . . . . . . . . . . . . . . . . . . . . . . . . . . 26.9 MPa, 269 bar (3900 psi) Maximum air input pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.7 MPa, 7 bar (100 psi) Pump cycles per 3.8 liters (1 gal.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Recommended pump speed for continuous operation . . . . . . . . . . . . . . . . . . 50 cycles per min Maximum flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23.75 liters/min (6.25 gpm) at 50 cycles/min Air motor piston effective area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800 cm@ (38.5 in.@) Stroke length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 mm (4.75 in.) Displacement pump effective area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 cm@ (3.255 in.@) Maximum pump operating temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65.5_C (150_F) Air inlet size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/4 npsm(f) Fluid outlet size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–1/2” npt(m) Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approx. 113 kg (248 lb) Displacement Pump Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approx. 37 kg (81 lb) Wetted parts . . . . . . . . . . . . . . . . Carbon Steel; Chrome, Zinc, and Electroless Nickel Plating;

304 and 17–4 PH Grades of Stainless Steel; E52100 Alloy Steel; Ductile Iron; Acetal; PTFE; Ultra-High Molecular Weight Polyethylene

KEY: Fluid Outlet Pressure – Black Curves

Air Consumption – Gray Curves

NOTE: Recommended pump speed for continuous operation (to shaded area): 50 cpm

A0.7 MPa, 7 bar (100 psi) Air Pressure

B0.49 MPa, 4.9 bar (70 psi) Air Pressure

C0.28 MPa, 2.8 bar (40 psi) Air Pressure

psi

 

 

 

 

 

 

psi

 

 

 

 

 

 

bar

 

cycles/min

 

 

 

bar

 

 

cycles/min

 

 

MPa

16

32

48

50

64

80

MPa

 

8

16

24

32

40

4000

4000

 

 

 

 

 

 

 

 

 

 

 

 

 

280

 

 

 

 

 

 

280

 

 

 

 

 

 

28.0

 

 

 

 

 

scfm

28.0

 

 

 

 

 

scfm

3500

 

 

 

 

 

3500

 

 

 

 

 

 

 

 

 

 

m#/min

 

 

 

 

 

m#/min

245

 

 

 

 

 

245

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

24.5

A

 

 

 

 

300

24.5

 

 

 

 

300

3000

 

 

 

 

3000

 

 

 

 

 

 

 

 

 

 

8.40

 

 

 

 

 

8.40

210

 

 

 

 

A

210

 

 

 

 

 

21.0

 

 

 

 

250

21.0

 

 

 

 

 

250

2500

 

 

 

 

 

2500

 

 

 

 

 

 

 

 

 

 

7.00

 

 

 

 

 

7.00

175

 

 

 

 

 

175

 

B

 

 

 

17.5

B

 

 

 

B

200

17.5

 

 

 

 

200

2000

 

 

 

 

5.60

2000

 

 

 

 

 

5.60

140

 

 

 

 

 

140

 

 

 

 

 

14.0

 

 

 

 

 

150

14.0

 

 

 

 

 

150

1500

 

 

 

 

 

1500

 

 

 

 

 

 

 

 

 

 

4.20

 

 

 

 

 

4.20

105

 

 

 

 

C

105

 

C

 

 

A

10.5

C

 

 

 

100

10.5

 

 

 

100

 

 

 

 

 

 

 

 

 

 

1000

 

 

 

 

1000

 

 

 

 

 

2.80

 

 

 

 

B

2.80

70

 

 

 

 

 

70

 

 

 

 

7.0

 

 

 

 

 

50

7.0

 

 

 

 

 

50

500

 

 

 

 

 

500

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

35

 

 

 

 

 

1.40

35

 

 

 

 

 

1.40

3.5

 

 

 

 

 

 

3.5

 

 

 

 

 

 

0

 

 

 

 

 

 

0

 

 

 

 

 

 

gpm 0

2

4

6

 

8

10

gpm

0

1

2

3

4

5

liters/min

7.6

15.2

22.8

30.4

38.0

liters/min

3.8

7.6

11.4

15.2

19.0

 

 

FLUID FLOW

 

 

 

 

 

FLUID FLOW

 

 

 

(TEST FLUID: 100,000 CENTIPOISE SEALANT)

 

 

(TEST FLUID: 4,000,000 CENTIPOISE SILICON)

To find Fluid Outlet Pressure (MPa/bar/psi) at a specific fluid flow

To find Pump Air Consumption (m#/min or scfm) at a specific fluid

(lpm/gpm) and operating air pressure (MPa/bar/psi):

flow (lpm/gpm) and air pressure (MPa/bar/psi):

1.

Locate desired flow along bottom of chart.

1.

Locate desired flow along bottom of chart.

2.

Follow vertical line up to intersection with selected fluid outlet

 

 

 

pressure curve (black). Follow left to scale to read fluid outlet

2.

Read vertical line up to intersection with selected air consumption

 

pressure.

 

curve (gray). Follow right to scale to read air consumption.

34 308149

Page 34
Image 34
Graco 308149P important safety instructions Model 222940 Premier Pump, Technical Data