OWNER’S MANUAL
INSTALLATION
Continued
9.Drill holes at marked locations using 3/16" drill bit.
10.Attach base assembly to fireplace floor using two masonry screws (in hardware package).
INSTALLING GWMS2 (OPTIONAL) WALL MOUNTED SWITCH
Items Included for Installation
•Switch
•Switch Cover (With Screws)
•25 Ft. Wire
CONNECTING TO GAS SUPPLY
WARNING: This appliance re- quires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator.
Flexible Gas Hose (if allowed by local codes)
Fitting
Figure 11 - Attaching Flexible Gas Hose to Heater
Masonry Screw
I
H
I
H
| O |
NO | FF |
Mounting
Flanges
Figure 12 - Attaching Base Assembly to Fireplace Floor
Connecting To Log Set
1.Connect one terminal of 25 ft. wire to bottom contact of switch located on heater front control panel (see Figure 13).
2.Connect remaining wire terminal to the “TH” terminal on the control valve (see Figure 13).
3.Route the 25 ft. wire to a convenient location.
WARNING: Do not connect the switch to a power source. Electrical shock and/or fire haz- ard will occur.
IMPORTANT: The wire may be shortened but must not be lengthened.
4.Connect one bare wire end to each of the terminals of the provided wall switch.
5.Install the wall switch and cover in the wall.
Switch
AUTO
OFF
ON
One |
| |
terminal | To Wall | |
of 25 ft. | ||
Switch | ||
wire | ||
|
To Wall
Switch
Wall Switch
Figure 13 - Connecting Wire Terminals
WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.
CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator be- tween the heater and propane/LP supply.
Installation Items Needed
Before installing heater, make sure you have the items listed below.
•external regulator (supplied by installer, see above)
•piping (check local codes)
•sealant (resistant to propane/LP gas)
•equipment shutoff valve *
•test gauge connection *
•sediment trap
•tee joint
•pipe wrench
*A CSA
The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 14, page 12. Pointing the vent down protects it from freezing rain or sleet.
Continued
105190 | 11 |