Vanguard Heating VYS30PWA, VYS24PWA Installing Logs, Pressure Testing Heater Gas Connections

Page 13

OWNER’S MANUAL

INSTALLATION

Continued

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 16).

2.Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve.

3.Check all joints from propane/LP sup- ply tank to equipment shutoff valve (see Figure 17). Apply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Propane/LP Supply Tank

Equipment Shutoff

Control Valve Location

Valve

Pressure Testing Heater Gas Connections

Figure 17 - Checking Gas Joints

INSTALLING LOGS

One Piece Log Set

 

1.Open equipment shutoff valve (see Fig- ure 16).

2.Open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to control valve (see Figure 17). Apply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 14 through 16). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 15).

Equipment

Shutoff Open

Valve

Closed

Figure 16 - Equipment Shutoff Valve

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, re- position logs according to the log installation instructions in this manual. Flames contacting logs will create soot.

It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place one-piece log set on grate to fit as illustrated in Figure 18. Make sure middle section at bottom of log set is seated into “U”-shaped cutout in cen- ter of chassis (see Figure 18). Log will fit securely on chassis. IMPORTANT: Make sure log does not cover any burner ports.

2.Place lava rock around base of heater.

 

Burner

Chassis

"U"-shaped

 

Cutout in

 

Chassis

Figure 18 - Installing Vintage Oak One- Piece Log Set

Burner

One Piece Log Set

Ports

 

Figure 19 - Installing Vintage Oak One- Piece Log set (Top View)

105190

13

Image 13
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSave this manual for future reference Vanguard Unvented PROPANE/LP GAS LOG Heater Safety InformationRemote Control Accessories Product FeaturesProduct Identification Local CodesProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsInstallation InstallationCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsMaterial Clearances Minimum NoncombustibleFloor Clearances Mantel ClearancesInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Area of Various Standard Round FluesConnecting to GAS Supply Installing GWMS2 Optional Wall Mounted SwitchItems Included for Installation Connecting To Log SetChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Installing LogsOperating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Pilot Flame Pattern Inspecting BurnersBurner Primary AIR Holes Main BurnerObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement at Specifications Wiring DiagramReplacement Parts Service HintsCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Vintage OAK LOG Models VYS18PWA, VYS24PWA VYS30PWA Illustrated Parts BreakdownVintage OAK LOG Models VYS18PWA, VYS24PWA, VYS30PWA Parts ListAccessories 105190 Warranty Information