Vanguard Heating VYS30PWA Inspecting Burners, Pilot Flame Pattern, Burner Primary AIR Holes

Page 16

VANGUARD

UNVENTED PROPANE/LP GAS LOG HEATER

OPERATING

HEATER

Continued

IMPORTANT: This remote control has been specially engineered to take an air temperature sample ev- ery 5.5 minutes in the auto mode. It will not respond immediately to the temperature setting being turned up or down.

IMPORTANT: The hand-held re- mote control unit must be near the heater. Do not keep the hand-held remote control unit too close to the heater. The thermostat on the hand-held remote control unit will heat up too quickly and turn the heater off.

3.To turn the burner off, press the AUTO/ON/OFF button until OFF lights. The pilot will remain lit.

IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position.

INSPECTING

BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 24 shows a correct pilot flame pat- tern. Figure 25 shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly heating the thermocouple. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 25

turn heater off (see To Turn Off Gas to Appliance, page 15)

see Troubleshooting, pages 17 through 19

Pilot Burner

Thermocouple

Figure 24 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 25 - Incorrect Pilot Flame Pattern

BURNER PRIMARY AIR HOLES

Air is drawn into the burner through the holes in the fitting at the burner entrance. These holes may become blocked with dust or lint. Periodically inspect these holes for any blockage and clean if needed. Blocked air holes will create soot.

Flame Adjustment Knob

 

 

 

Control Knob in

IH

 

 

On Position

 

F

PIL

ON

 

O

 

O

 

T

OFF

 

O

 

 

 

 

N

REMOTE

 

 

 

 

 

LO

 

 

 

Selector Switch in Remote Position

(Optional Remote Control)

Figure 22 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may be- come blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage. Blocked burner flame holes will create soot.

Shows Temperature Setting

The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected

Increases Room

Temperature in

AUTO Mode

Decreases Room

Temperature in

AUTO Mode

Turns Burners On or Off and Allows You to Choose the Auto Setting

Figure 23 - Thermostat Hand-Held Remote Control Unit Selections (GHRCTA Series only)

16

105190

Image 16
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSave this manual for future reference Safety Information Vanguard Unvented PROPANE/LP GAS LOG HeaterProduct Features Remote Control AccessoriesProduct Identification Local CodesAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation InstallationCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsMinimum Noncombustible Material ClearancesMantel Clearances Floor ClearancesInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Area of Various Standard Round FluesInstalling GWMS2 Optional Wall Mounted Switch Connecting to GAS SupplyItems Included for Installation Connecting To Log SetPressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Logs Pressure Testing Heater Gas ConnectionsOperating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Inspecting Burners Pilot Flame PatternBurner Primary AIR Holes Main BurnerTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement at Wiring Diagram SpecificationsReplacement Parts Service HintsCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Illustrated Parts Breakdown Vintage OAK LOG Models VYS18PWA, VYS24PWA VYS30PWAParts List Vintage OAK LOG Models VYS18PWA, VYS24PWA, VYS30PWAAccessories 105190 Warranty Information