VANGUARD
UNVENTED PROPANE/LP GAS LOG HEATER
OPERATING
HEATER
Continued
IMPORTANT: This remote control has been specially engineered to take an air temperature sample ev- ery 5.5 minutes in the auto mode. It will not respond immediately to the temperature setting being turned up or down.
IMPORTANT: The
3.To turn the burner off, press the AUTO/ON/OFF button until OFF lights. The pilot will remain lit.
IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position.
INSPECTING
BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 24 shows a correct pilot flame pat- tern. Figure 25 shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly heating the thermocouple. When the thermocouple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in Figure 25
•turn heater off (see To Turn Off Gas to Appliance, page 15)
•see Troubleshooting, pages 17 through 19
Pilot Burner
Thermocouple
Figure 24 - Correct Pilot Flame Pattern
Pilot Burner
Thermocouple
Figure 25 - Incorrect Pilot Flame Pattern
BURNER PRIMARY AIR HOLES
Air is drawn into the burner through the holes in the fitting at the burner entrance. These holes may become blocked with dust or lint. Periodically inspect these holes for any blockage and clean if needed. Blocked air holes will create soot.
Flame Adjustment Knob
|
|
| Control Knob in |
IH |
|
| On Position |
| F | PIL | |
ON |
| O | |
| O |
| T |
OFF |
| O | |
|
| ||
|
| N | |
REMOTE |
|
| |
|
|
| |
LO |
|
|
|
Selector Switch in Remote Position
(Optional Remote Control)
Figure 22 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation
MAIN BURNER
Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may be- come blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage. Blocked burner flame holes will create soot.
Shows Temperature Setting
The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected
Increases Room
Temperature in
AUTO Mode
Decreases Room
Temperature in
AUTO Mode
Turns Burners On or Off and Allows You to Choose the Auto Setting
Figure 23 - Thermostat Hand-Held Remote Control Unit Selections (GHRCTA Series only)
16 | 105190 |