TECHNICAL

SERVICE

SPECIFICATIONS

SERVICE

HINTS

REPLACEMENT PARTS

28

You may have further questions about installation, operation, or troubleshooting.

If so, contact DESA International’s Technical Service Department at 1-800-323-5190.

Btu (Variable)

14,000/26,000

Type Gas

Natural Only

Ignition

Piezo

Pressure Regulator Setting

3" W.C.

Inlet Gas Pressure (in. of water) *

 

Maximum

10.5"

Minimum

5"

Dimensions, Inches (H x W x D)

 

Fireplace (including hood and screws) 257/8 x 2613/16 x 93/8

Carton

325/8 x 273/16 x 115/8

Weight, pounds

441/2 lbs.

Fireplace

Shipping

48 lbs.

* For purposes of input adjustment

When gas pressure is too low

pilot will not stay lit

burner will have delayed ignition

fireplace will not produce specified heat

When gas quality is bad

pilot will not stay lit

burner will produce flames and soot

fireplace will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

Parts Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International’s Technical Service Department at 1-800-323-5190 for referral information.

When calling DESA International, have ready

your name

your address

model number of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the defective part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International’s Parts Department at 1-800-972-7879 for referral information.

When calling DESA International, have ready

model number of your fireplace

the replacement part number

102885

Image 28
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information 001 Local Codes Product Features Unpacking Safety PilotPiezo Ignition System Thermostatic Heat ControlAssembly Installing LogAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Fireplace Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Ventilation Air from Outdoors Shown with Optional MantelInstallation Installation ItemsCheck GAS Type Locating FireplaceCeiling Installing BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Side Firebox Mantel ShelfOptional Mantel Installation Attaching Brass Trim to FireplaceAssembling Brass Trim Brass trim shipped with mantel Attaching Wood Base to Solid FloorConnecting to GAS Supply Gas ConnectionConnecting Fireplace to GAS Supply Installation Items NeededPressure Testing Fireplace GAS Connections Pressure Testing GAS Supply Piping SystemChecking GAS Connections Operating Fireplace Pilot Shutting Off Fireplace Operating FireplaceShutting Off Burner Only pilot stays lit Inspecting Burner Pilot Flame PatternBurner Flame Pattern Correct Burner Flame PatternODS/PILOT and Burner Cleaning and Maintenance Trouble ShootingCabinet See Cleaning TROUBLE- ShootingCleaning and Mainte Ing statement at TopTechnical Service Service HintsParts Under Warranty Parts Not Under WarrantyAccessories Valve GA5010GA3400T Unfinished GM921U Finished GM920FVMH26TN Parts List Model VMH26TNWarranty Information Keep this Warranty

VMH26TN specifications

The Vanguard Heating VMH26TN is a cutting-edge heating unit designed to provide efficient and consistent warmth for residential and commercial spaces. With its sleek design and advanced technology, this model has garnered attention for its reliability and performance.

One of the standout features of the VMH26TN is its powerful heating capability. It boasts a maximum output of 26,000 BTUs, making it suitable for heating medium to large rooms with ease. This makes it an ideal choice for living spaces, offices, and even workshops that require a dependable source of heat during the colder months.

The unit incorporates innovative heating technologies that enhance its efficiency. It utilizes a high-efficiency burner system that maximizes fuel consumption, thereby reducing energy costs. The VMH26TN is designed to operate with minimal emissions, making it an environmentally friendly option for those conscious of their carbon footprint.

The VMH26TN features a user-friendly digital thermostat that allows users to easily set their desired temperature. The thermostat ensures precise temperature control, helping to maintain a consistent and comfortable environment. Additionally, the unit includes programmable settings that enable users to schedule heating times according to their lifestyle, optimizing energy use and comfort.

Another critical characteristic of the VMH26TN is its robust construction. Built from high-quality materials, this heating unit is designed for durability and longevity, providing peace of mind for users. Its compact design ensures that it can fit into various spaces without compromising on performance.

Safety features are also a priority in the VMH26TN design. It includes an automatic shut-off function that activates in case of overheating or other malfunctions, protecting both the unit and your space. The built-in safety sensors monitor the operation continuously to ensure optimal functionality while minimizing risks.

In summary, the Vanguard Heating VMH26TN combines powerful heating capacity, advanced efficiency technology, and user-friendly features in a robust and safe design. Whether for a home or commercial setting, this heating unit stands out as a reliable choice for anyone looking to achieve warmth and comfort efficiently.