AIR FOR COMBUSTION AND VENTILATION

Continued

WARNING

WARNING ICON

G 001

If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide adequate combus- tion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3 or appli- cable local codes.

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 4). You can also remove door into adjoining room (see option 3, Figure 4). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

WARNING

WARNING ICON

G 001

 

 

Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

Ventilation

 

Grills

Or

into Adjoining

Remove

Room,

Door into

Option 1

Adjoining

 

Room,

 

Option 3

12"

Ventilation Grills

Into Adjoining Room,

Option 2

8

12"

Figure 4 - Ventilation Air from Inside Building Shown with Optional Mantel

102885

Image 8
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information 001 Local Codes Product Features Unpacking Safety PilotPiezo Ignition System Thermostatic Heat ControlAssembly Installing LogAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Fireplace Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Ventilation Air from Outdoors Shown with Optional MantelInstallation Installation ItemsCheck GAS Type Locating FireplaceCeiling Installing BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Side Firebox Mantel ShelfOptional Mantel Installation Attaching Brass Trim to FireplaceAssembling Brass Trim Brass trim shipped with mantel Attaching Wood Base to Solid FloorConnecting to GAS Supply Gas ConnectionConnecting Fireplace to GAS Supply Installation Items NeededChecking GAS Connections Pressure Testing GAS Supply Piping SystemPressure Testing Fireplace GAS Connections Operating Fireplace Pilot Shutting Off Burner Only pilot stays lit Operating FireplaceShutting Off Fireplace Inspecting Burner Pilot Flame PatternBurner Flame Pattern Correct Burner Flame PatternCabinet Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner See Cleaning TROUBLE- ShootingCleaning and Mainte Ing statement at TopTechnical Service Service HintsParts Under Warranty Parts Not Under WarrantyAccessories Valve GA5010GA3400T Unfinished GM921U Finished GM920FVMH26TN Parts List Model VMH26TNWarranty Information Keep this Warranty

VMH26TN specifications

The Vanguard Heating VMH26TN is a cutting-edge heating unit designed to provide efficient and consistent warmth for residential and commercial spaces. With its sleek design and advanced technology, this model has garnered attention for its reliability and performance.

One of the standout features of the VMH26TN is its powerful heating capability. It boasts a maximum output of 26,000 BTUs, making it suitable for heating medium to large rooms with ease. This makes it an ideal choice for living spaces, offices, and even workshops that require a dependable source of heat during the colder months.

The unit incorporates innovative heating technologies that enhance its efficiency. It utilizes a high-efficiency burner system that maximizes fuel consumption, thereby reducing energy costs. The VMH26TN is designed to operate with minimal emissions, making it an environmentally friendly option for those conscious of their carbon footprint.

The VMH26TN features a user-friendly digital thermostat that allows users to easily set their desired temperature. The thermostat ensures precise temperature control, helping to maintain a consistent and comfortable environment. Additionally, the unit includes programmable settings that enable users to schedule heating times according to their lifestyle, optimizing energy use and comfort.

Another critical characteristic of the VMH26TN is its robust construction. Built from high-quality materials, this heating unit is designed for durability and longevity, providing peace of mind for users. Its compact design ensures that it can fit into various spaces without compromising on performance.

Safety features are also a priority in the VMH26TN design. It includes an automatic shut-off function that activates in case of overheating or other malfunctions, protecting both the unit and your space. The built-in safety sensors monitor the operation continuously to ensure optimal functionality while minimizing risks.

In summary, the Vanguard Heating VMH26TN combines powerful heating capacity, advanced efficiency technology, and user-friendly features in a robust and safe design. Whether for a home or commercial setting, this heating unit stands out as a reliable choice for anyone looking to achieve warmth and comfort efficiently.