Vanguard Heating VMH3000TP Mounting Heater to Optional Mantel, Securing Hearth Base to Floor

Page 11

OWNER’S MANUAL

INSTALLATION

Continued

Mounting Heater to Optional Hearth Base

1.

Lay heater on its back on a table with

 

the bottom of heater overhanging the

 

edge of the table.

2.

Remove 2 shipping screws in bottom

 

of heater. Discard shipping screws.

3.

Line up mounting holes on top of hearth

 

base with holes in bottom of heater (see

 

Figure 18).

4.

Using a Phillips screwdriver, secure

 

hearth base to heater with four sheet

 

metal screws (see Figure 18).

5.

Stand heater up on base.

6.

Place hearth insert in hearth base as

 

shown in Figure 19.

7.

Assemble brass trim (see steps 1

 

through 7 under Assembling and At-

 

taching Brass Trim, page 4).

8.

Slide base trim on heater base. Attach

Securing Hearth Base to Floor

1.Position hearth base in desired location. Mark holes for drilling (See Figure 18). Remove hearth base.

2.For carpeted floor, make a small cut with a sharp knife at marked locations before drilling.

If securing to a wood floor, drill a 3/4" deep hole using a 1/8" diameter drill bit. Do not use anchors in wood floors. If securing to a concrete floor, drill a 1 3/8" deep hole using a 1/4" diameter concrete drill bit. Completely insert anchors into each hole.

3.Mount heater to hearth base following steps under Mounting Heater to Op- tional Hearth Base. After mounting heater, position heater and hearth base over drilled holes. With slotted screw- driver, secure hearth base to floor with four wood screws.

C. MOUNTING HEATER TO OPTIONAL MANTEL.

See Instructions Included With Mantel Kit.

IMPORTANT: Only use the optional man- tels specified in this manual. See Accesso- ries, page 23 for proper mantel kits. This heater is only approved for use with models GMF800/GMU801 series, GM900F/ GM901U series, GM902F/GM903U series, GM700F/GM701U, and GM702F/ GM703U series mantel kits. Using any other mantel will void the CSA/AGA approval for this heater. Only use models GMF800/ GMU801 series, GM900F/GM901U series, GM902F/GM903U series, GM700F/ GM701U, and GM702F/GM703U series mantels with this heater. Do not use these mantels with any other product.

brass trim to base with two brass screws

included as shown in Figure 19.

Shipping Screw

Bottom of Heater

Base

 

Mounting

 

Holes

Holes for Securing

Sheet Metal

Heater to Floor

Screw

Figure 18 - Attaching Heater to Hearth Base

Hearth

Insert

Screw

Brass Base

Trim

Figure 19 - Placing Hearth Insert on Heater

Base and Attaching Brass Base Trim

Continued

104432

11

Image 11
Contents What to do if YOU Smell GAS VENT-FREE PROPANE/LP GAS MINI-HEARTHHEATERLocal Codes Safety InformationUnpacking AssemblyProduct Features Product IdentificationLocate brass front trim in brass trim package Attaching Brass Front Trim to Front PanelAssembling and Attaching Brass Trim Confined and Unconfined Space Fresh AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors AIR for Combustion and VentilationVentilation AIR Ventilation Air From Inside BuildingLocating Heater InstallationInstallation Items Check GAS TypeMounting Heater to Wall Installation OptionsThermostat Sensing Bulb Placing Heater On Mounting Bracket Installing Bottom Mounting ScrewsMounting Heater on Optional Hearth Base Securing Hearth Base to Floor Mounting Heater to Optional MantelMounting Heater to Optional Hearth Base External Regulator with Vent Pointing Down Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections To Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Heater Lighting InstructionsPilot Flame Pattern Manual Lighting ProcedureInspecting Burner Thermostat Control OperationAfter ODS/pilot lights, keep control TroubleshootingPilot assembly Safety interlock system has been trigPane/LP company Maintenance,Top Gas odor even when control knob is in OFFReplacement Parts Cleaning and MaintenanceVMH3000TP Illustrated Parts BREAKDOWN21KEY VMH3000TP Description QTY Parts ListWhen Gas Pressure Is Too Low SpecificationsTechnical Service Service HintsAccessories Warranty Information

VMH3000TP specifications

The Vanguard Heating VMH3000TP is a state-of-the-art heating solution designed to provide efficient and powerful warmth for residential and commercial spaces. This unit stands out in the market due to its robust performance, advanced technology, and user-friendly features.

One of the key features of the VMH3000TP is its impressive heating capacity, which can efficiently warm large areas up to 3,000 square feet, making it an ideal choice for homes, warehouses, and workshops. Its powerful heating mechanism ensures rapid temperature rise, ensuring comfort even in the coldest conditions.

The VMH3000TP utilizes cutting-edge technologies, including an intelligent thermostat that allows users to program specific heating schedules according to their needs. This feature not only enhances user convenience but also contributes to energy efficiency, helping to reduce heating costs and minimize environmental impact.

Additionally, the unit is equipped with a multi-stage filtration system that helps maintain indoor air quality. This filters out dust, allergens, and other airborne particles, ensuring a healthier living environment. The filtration system is easy to access and replace, providing a hassle-free maintenance experience.

Another notable characteristic of the VMH3000TP is its silent operation. Unlike traditional heating solutions that can produce distracting noise, this unit operates quietly, ensuring comfort without disturbance. This feature is particularly beneficial for residential applications, where peace and quiet are essential.

The VMH3000TP also boasts a sleek and modern design that can seamlessly blend into various decor styles. Its compact form ensures that it occupies minimal space, making it suitable for installation in smaller areas without compromising on performance.

Safety is paramount in the design of the VMH3000TP. It incorporates several safety features, including overheat protection and an automatic shut-off function. These safety mechanisms provide users with peace of mind, knowing that their heating system is both effective and secure.

In summary, the Vanguard Heating VMH3000TP combines powerful heating capacity, advanced technologies, and user-friendly features to deliver an exceptional heating experience. With its energy efficiency, air quality improvement, silent operation, and safety features, it is a remarkable choice for anyone looking to invest in a high-quality heating solution.