CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, pet hair, bedding material, etc.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, and lint. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We rec- ommend that you clean the unit every 2,500 hours of operation or every three months.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recom- mend using compressed air no greater than 30 PSI. Your local computer store, hard- ware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the direc- tions on the can. If you don't follow direc- tions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 30).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hairs with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 31). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Injector Holder

Ports/Slots

Burner

Tube

Primary Air Inlet

Holes

Figure 30 - Injector Holder On Outlet Burner Tube

Pilot Air Inlet

Hole

Pilot Assembly

Figure 31 - Pilot Inlet Air Hole

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabi- net to remove dust.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Techni- cal Service Department at 1-800-323-5190 for referral information.

When calling DESA International, have ready

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the defec- tive part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information.

When calling DESA International, have ready

model number of your heater

the replacement part number

104432

19

Image 19
Contents What to do if YOU Smell GAS VENT-FREE PROPANE/LP GAS MINI-HEARTHHEATERLocal Codes Safety InformationUnpacking AssemblyProduct Features Product IdentificationAssembling and Attaching Brass Trim Attaching Brass Front Trim to Front PanelLocate brass front trim in brass trim package Confined and Unconfined Space Fresh AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors AIR for Combustion and VentilationVentilation AIR Ventilation Air From Inside BuildingLocating Heater InstallationInstallation Items Check GAS TypeThermostat Sensing Bulb Installation OptionsMounting Heater to Wall Mounting Heater on Optional Hearth Base Installing Bottom Mounting ScrewsPlacing Heater On Mounting Bracket Mounting Heater to Optional Hearth Base Mounting Heater to Optional MantelSecuring Hearth Base to Floor External Regulator with Vent Pointing Down Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections To Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Heater Lighting InstructionsPilot Flame Pattern Manual Lighting ProcedureInspecting Burner Thermostat Control OperationAfter ODS/pilot lights, keep control TroubleshootingPilot assembly Safety interlock system has been trigPane/LP company Maintenance,Top Gas odor even when control knob is in OFFReplacement Parts Cleaning and MaintenanceVMH3000TP Illustrated Parts BREAKDOWN21KEY VMH3000TP Description QTY Parts ListWhen Gas Pressure Is Too Low SpecificationsTechnical Service Service HintsAccessories Warranty Information

VMH3000TP specifications

The Vanguard Heating VMH3000TP is a state-of-the-art heating solution designed to provide efficient and powerful warmth for residential and commercial spaces. This unit stands out in the market due to its robust performance, advanced technology, and user-friendly features.

One of the key features of the VMH3000TP is its impressive heating capacity, which can efficiently warm large areas up to 3,000 square feet, making it an ideal choice for homes, warehouses, and workshops. Its powerful heating mechanism ensures rapid temperature rise, ensuring comfort even in the coldest conditions.

The VMH3000TP utilizes cutting-edge technologies, including an intelligent thermostat that allows users to program specific heating schedules according to their needs. This feature not only enhances user convenience but also contributes to energy efficiency, helping to reduce heating costs and minimize environmental impact.

Additionally, the unit is equipped with a multi-stage filtration system that helps maintain indoor air quality. This filters out dust, allergens, and other airborne particles, ensuring a healthier living environment. The filtration system is easy to access and replace, providing a hassle-free maintenance experience.

Another notable characteristic of the VMH3000TP is its silent operation. Unlike traditional heating solutions that can produce distracting noise, this unit operates quietly, ensuring comfort without disturbance. This feature is particularly beneficial for residential applications, where peace and quiet are essential.

The VMH3000TP also boasts a sleek and modern design that can seamlessly blend into various decor styles. Its compact form ensures that it occupies minimal space, making it suitable for installation in smaller areas without compromising on performance.

Safety is paramount in the design of the VMH3000TP. It incorporates several safety features, including overheat protection and an automatic shut-off function. These safety mechanisms provide users with peace of mind, knowing that their heating system is both effective and secure.

In summary, the Vanguard Heating VMH3000TP combines powerful heating capacity, advanced technologies, and user-friendly features to deliver an exceptional heating experience. With its energy efficiency, air quality improvement, silent operation, and safety features, it is a remarkable choice for anyone looking to invest in a high-quality heating solution.