Vanguard Heating VMH3000TP installation manual Maintenance, Pane/LP company

Page 17

OWNER’S MANUAL

TROUBLESHOOTING

Continued

 

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

Burner does not light after ODS/pilot is lit

1.

Burner orifice is clogged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 19) or replace burner orifice

 

 

2.

Burner orifice diameter is too small

2.

Replace burner orifice

 

 

3.

Inlet gas pressure is too low

3.

Contact local propane/LP company

 

 

 

 

 

 

 

Delayed ignition of burner

1.

Manifold pressure is too low

1.

Contact local propane/LP company

 

 

2.

Burner orifice is clogged

2.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 19) or replace burner orifice

 

 

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 19) or replace burner orifice

 

 

2.

Burner damaged

2.

Replace burner

 

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

 

 

Yellow flame during burner combustion

1.

Not enough air

1.

Check burner for dirt and debris. If

 

 

 

 

 

found, clean burner (see Cleaning and

 

 

 

 

 

Maintenance, page 19)

 

 

2.

Gas regulator defective

2.

Replace gas regulator

 

 

 

 

 

 

 

Slight smoke or odor during initial operation

1.

Residues from manufacturing processes

1.

Problem will stop after a few hours of

 

 

 

 

 

operation

 

 

 

 

 

 

 

Heater produces a whistling noise when

1.

Turning control knob to HI position

1.

Turn control knob to LO position and

 

burner is lit

 

when burner is cold

 

let warm up for a minute

 

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

 

line. Have gas line checked by local pro-

 

 

 

 

 

pane/LP company

 

 

3.

Air passageways on heater blocked

3.

Observe minimum installation clear-

 

 

 

 

 

ances (see Figure 10, page 8)

 

 

4.

Dirty or partially clogged burner orifice

4.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 19) or replace burner orifice

White powder residue forming within burner box or on adjacent walls or furniture

1.When heated, vapors from furniture pol- ish, wax, carpet cleaners, etc. turn into white powder residue

1.Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

www.desatech.com

Continued

104432

17

Image 17
Contents What to do if YOU Smell GAS VENT-FREE PROPANE/LP GAS MINI-HEARTHHEATERLocal Codes Safety InformationProduct Features AssemblyProduct Identification UnpackingLocate brass front trim in brass trim package Attaching Brass Front Trim to Front PanelAssembling and Attaching Brass Trim Providing Adequate Ventilation Fresh AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR AIR for Combustion and VentilationVentilation Air From Inside Building Ventilation Air From OutdoorsInstallation Items InstallationCheck GAS Type Locating HeaterMounting Heater to Wall Installation OptionsThermostat Sensing Bulb Placing Heater On Mounting Bracket Installing Bottom Mounting ScrewsMounting Heater on Optional Hearth Base Securing Hearth Base to Floor Mounting Heater to Optional MantelMounting Heater to Optional Hearth Base External Regulator with Vent Pointing Down Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Operating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To ApplianceInspecting Burner Manual Lighting ProcedureThermostat Control Operation Pilot Flame PatternPilot assembly TroubleshootingSafety interlock system has been trig After ODS/pilot lights, keep controlPane/LP company Maintenance,Top Gas odor even when control knob is in OFFReplacement Parts Cleaning and MaintenanceVMH3000TP Illustrated Parts BREAKDOWN21KEY VMH3000TP Description QTY Parts ListTechnical Service SpecificationsService Hints When Gas Pressure Is Too LowAccessories Warranty Information

VMH3000TP specifications

The Vanguard Heating VMH3000TP is a state-of-the-art heating solution designed to provide efficient and powerful warmth for residential and commercial spaces. This unit stands out in the market due to its robust performance, advanced technology, and user-friendly features.

One of the key features of the VMH3000TP is its impressive heating capacity, which can efficiently warm large areas up to 3,000 square feet, making it an ideal choice for homes, warehouses, and workshops. Its powerful heating mechanism ensures rapid temperature rise, ensuring comfort even in the coldest conditions.

The VMH3000TP utilizes cutting-edge technologies, including an intelligent thermostat that allows users to program specific heating schedules according to their needs. This feature not only enhances user convenience but also contributes to energy efficiency, helping to reduce heating costs and minimize environmental impact.

Additionally, the unit is equipped with a multi-stage filtration system that helps maintain indoor air quality. This filters out dust, allergens, and other airborne particles, ensuring a healthier living environment. The filtration system is easy to access and replace, providing a hassle-free maintenance experience.

Another notable characteristic of the VMH3000TP is its silent operation. Unlike traditional heating solutions that can produce distracting noise, this unit operates quietly, ensuring comfort without disturbance. This feature is particularly beneficial for residential applications, where peace and quiet are essential.

The VMH3000TP also boasts a sleek and modern design that can seamlessly blend into various decor styles. Its compact form ensures that it occupies minimal space, making it suitable for installation in smaller areas without compromising on performance.

Safety is paramount in the design of the VMH3000TP. It incorporates several safety features, including overheat protection and an automatic shut-off function. These safety mechanisms provide users with peace of mind, knowing that their heating system is both effective and secure.

In summary, the Vanguard Heating VMH3000TP combines powerful heating capacity, advanced technologies, and user-friendly features to deliver an exceptional heating experience. With its energy efficiency, air quality improvement, silent operation, and safety features, it is a remarkable choice for anyone looking to invest in a high-quality heating solution.