Vanguard Heating VMH3000TP Connecting to GAS Supply, External Regulator with Vent Pointing Down

Page 12

®

VENT-FREE GAS RESIDENTIAL HEATERS

INSTALLATION

Continued

CONNECTING TO GAS SUPPLY

WARNING: This appliance re- quires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator.

WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.

WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" or greater diameter to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 21).

IMPORTANT: Install an equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

We recommend that you install sediment trap in supply line as shown in Figure 21. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

IMPORTANT: Hold pressure regulator with wrench when connecting it to gas pip- ing and/or fittings.

incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure

20.Pointing the vent down protects it from freezing rain or sleet.

Propane/LP

Supply Tank

External

Regulator

Vent

Pointing

Down

Figure 20 - External Regulator with Vent Pointing Down

Pressure

Regulator

3/8" NPT Pipe Nipple

 

 

 

 

Tee Joint

 

 

 

 

Reducer

Test Gauge

 

 

 

Bushing to

 

 

 

1/8" NPT

Connection *

 

 

 

 

 

 

 

 

 

 

 

1/8" NPT

 

 

 

 

Plug Tap

Sediment Trap

 

 

 

 

Tee Joint

 

 

 

 

 

 

 

 

Pipe Nipple

 

 

 

 

 

 

 

 

 

 

Note: Burner bracket not shown for clarity

Ground

 

Heater

 

Cabinet

Union Joint

 

 

Equipment

 

 

Shutoff Valve *

 

From External

 

Regulator (11" W.C.

 

to 14" W.C. Pressure)

3" Minimum

 

 

Cap

Figure 21 - Gas Connection

*A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design-certified equipment shutoff valve from your dealer. See Accessories, page 23.

12

104432

Image 12
Contents VENT-FREE PROPANE/LP GAS MINI-HEARTHHEATER What to do if YOU Smell GASSafety Information Local CodesAssembly Product FeaturesProduct Identification UnpackingAttaching Brass Front Trim to Front Panel Assembling and Attaching Brass TrimLocate brass front trim in brass trim package Fresh AIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space AIR for Combustion and Ventilation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsInstallation Installation ItemsCheck GAS Type Locating Heater Installation Options Thermostat Sensing Bulb Mounting Heater to Wall Installing Bottom Mounting Screws Mounting Heater on Optional Hearth BasePlacing Heater On Mounting Bracket Mounting Heater to Optional Mantel Mounting Heater to Optional Hearth BaseSecuring Hearth Base to Floor Connecting to GAS Supply External Regulator with Vent Pointing DownPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections For Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS To ApplianceManual Lighting Procedure Inspecting BurnerThermostat Control Operation Pilot Flame PatternTroubleshooting Pilot assemblySafety interlock system has been trig After ODS/pilot lights, keep controlMaintenance, Pane/LP companyGas odor even when control knob is in OFF TopCleaning and Maintenance Replacement PartsIllustrated Parts BREAKDOWN21 VMH3000TPParts List KEY VMH3000TP Description QTYSpecifications Technical ServiceService Hints When Gas Pressure Is Too LowAccessories Warranty Information