TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/pilot

1.Ignitor electrode not connected to igni- tor cable

2.Ignitor cable pinched or wet

3.Piezo ignitor nut is loose

4.Broken ignitor cable

5.Bad piezo ignitor

6.Ignitor electrode broken

7.Ignitor electrode positioned wrong

1.Reconnect ignitor cable

2.Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry

3.Tighten nut holding piezo ignitor to base panel of log set. Nut is located behind base panel.

4.Replace ignitor cable

5.Replace piezo ignitor

6.Replace piezo ignitor

7.Replace piezo ignitor

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1.Gas supply turned off or manual shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PILOT position

4.Air in gas lines when installed

5.ODS/pilot is clogged

6.Gas regulator setting is not correct

1.Turn on gas supply or open manual shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down control knob. Repeat igniting operation until air is removed

5.Clean ODS/pilot (see Cleaning and Maintenance, page 18) or replace ODS/ pilot assembly

6.Replace gas control

ODS/pilot lights but flame goes out when control knob is released

1.Control knob not fully pressed in

2.Control knob not pressed in long enough

3.Manual shutoff valve not fully open

4.Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This prob- lem could be caused by one or both of the following:

A)Low gas pressure

B)Dirty or partially clogged OD S/pilot

5.Thermocouple connection loose at con- trol valve

6.Thermocouple damaged

7.Control valve damaged

1.Press in control knob fully

2.After ODS/pilot lights, keep control knob pressed in 30 seconds

3.Fully open manual shut-off valve

4.A) Contact local natural gas company

B) Clean ODS/pilot (see Cleaning and Maintenance, page 18) or replace ODS/ pilot assembly

5.Hand tighten until snug, then tighten 1/4 turn more

6.Replace thermocouple

7.Replace control valve

www.desatech.com

Continued

105273

19

Image 19
Contents Patent Pending OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS 18, 24, 30, and 36 Remote Ready ModelVanguard Flame MAX Unvented Natural GAS LOG Heater Safety InformationLocal Codes Product FeaturesRemote Control Accessories Product IdentificationConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingMinimum Wall and Ceiling Clearances see Figure InstallationInstallation Check GAS TypeIf Not Using Mantel If Using MantelMinimum Noncombustible Material Clearances Determining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationChimney Minimum Permanent Height ft Flue Opening sq. ins Attaching Flexible Gas Hose to Heater Installation Items NeededWrench when connecting it to gas piping and/or fittings Connecting to GAS SupplyTest Pressures In Excess Of 1/2 Psig Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Checking GAS ConnectionsPlace lava rock around base of heater Installing LogsOperating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Main Burner Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Observed Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement at top TopIllustrated Parts Breakdown VYD18NRA, VYD24NRA VYD30NRA, and VYD36NR Parts ListTechnical Service Wiring Diagram Replacement PartsSpecifications Service HintsAccessories International Warranty Information