Majestic Appliances 3106, 3112, 3111, 3101, 3097, 3100, 3096, 3102 Juvs Specifications, Accessories

Page 3

Vermont Castings Jefferson Vent Free Gas Heater

JUVS Specifications

Jefferson Vent Free Gas Heater Models JUVSRN, JUVSRP, JUVSMN, JUVSMP

Fuel

 

NG

LP

 

Manifold Pressure Min./Max.

1.7”/3.5”

5.4”/11.0” (RP)

 

 

 

4.4”/10.0” (MP)

Min. Inlet Supply Pressure for adjustment:

5.5”w.c.

11.0”w.c.

Max. Inlet Supply Pressure for adjustment:

14.0”w.c.

14.0”w.c.

Min. Output, BTU/hr:

 

 

 

 

JUVSR

 

20,000

21,000

 

JUVSM

 

18.500

18.500

 

Max. Output, BTU/hr:

 

28,000

28,000

 

Ignition:

Piezo

 

 

 

Firebox Weight/shipping:

110 lbs.

 

 

 

 

Accessories

This appliance may be installed in an aftermarket*

 

 

#2960 FK28 Fan Kit

manufactured (mobile) home, where not prohibited

by state or local codes.

IMT Optional Wall Thermostat

 

MRC1 ZC1100 Remote Control (ON/OFF w/batteries)

This appliance is only for use with the type of gas

MRC2 ZC1200 Remote Control (ON/OFF thermostat

indicated on the Rating Plate. This appliance is not

 

w/batteries)

 

convertible for use with other gases.

MRC3 ZC1300 Remote Control (LCD ON/OFF

 

thermostat, timer w/batteries)

*Aftermarket: Completion of sale, not for purpose of resale, from the

 

manufacturer.

28Z\x"

(724mm)

 

Valve

 

Inlet C

 

L

 

3" (76mm)

24"

14Z\x"

(610mm)

(368mm)

8"

(203mm)

3447

Fig. 1 Jefferson Vent Free dimensions.

3

Image 3
Contents Jefferson Table of Contents Accessories Juvs SpecificationsSafety Information High Altitude DeratingCarbon Monoxide Poisoning MAY Lead to Death To remove the packaged log set from the firebox Vent Free FeaturesGeneral Information Unpack the StoveDetermine If You Have a Confined or Unconfined Space Installation RequirementsProvide for Adequate Ventilation Unusually Tight ConstructionSupplementing ventilation air Hearth Requirements Minimum Clearances to Combustible MaterialsOptional Fan Kit Installation 2960/FK28 Assembly ProceduresInstall the Log Set Connect the Gas Supply LineAged Logs Thermostat Connection optional Install ON/OFF SwitchOperation Your First FirePilot and Burner Inspection Correct Pilot Flame. *JUVSM pilots do not have Thermopile What to do if YOU Smell GAS To Turn Off Gas To HeaterCare of Cast Iron MaintenanceFirebox Cleaning and Inspection Cleaning ProcedureTroubleshooting No spark at pilot when Ignitor is operatedIgnitor Electrode sparks, but Pilot does not light Pilot lights but Main Burner does not Main Burner shuts off and PilotFlame goes out while in operation Models Only Odor During OperationJefferson Vent Free Gas Heater Juvs Warranty Vermont Castings Majestic Products Company